Advanced Optical Cavity Probes
Presentation describes evolution of optical cavity probe design since 2010, with probe designs getting smaller and adding more beams.
Engineering topics
Publications and source records attributed to Frogget, Brent.
Presentation describes evolution of optical cavity probe design since 2010, with probe designs getting smaller and adding more beams.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
“A picture tells a thousand words”—this is a concept that captivates everyone, from the casual observer to the experimental physics scientist. To bring this concept to light in support of Stockpile Stewardship subcritical experiments executed at the Nevada National Security Site (NNSS), we have developed a new diagnostic tool to investigate the behavior of materials under high-explosive dynamic shock conditions. For the Leda subcritical experiment executed in August, 2014, a single line-of-sight imaging system was designed and fielded as a stretch diagnostic goal for National Security Technologies, LLC (NSTec). For the Lyra series, beginning with the Orpheus experiment in September 2015, a newly created dynamic stereo surface imaging (DSSI) capability was deployed. The DSSI diagnostic records a high-speed image sequence that allows scientists to peer inside an imploding hydrodynamic test article with stereoscopic imaging.
This paper describes a convenient and accurate method to calibrate fast (<1 ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such systems are inherently difficult to calibrate due to the lack of sufficiently intense, calibrated light sources. Such a system is used to collect spectral data on plasmas generated in electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA) at Sandia National Laboratories. On RITS, plasma light is collected through a small diameter (200 {mu}m) optical fiber and recorded on a fast streak camera at the output of a 1 meter Czerny-Turner monochromator. For this paper, a 300 W xenon short arc lamp (Oriel Model 6258) was used as the calibration source. Since the radiance of the xenon arc varies from cathode to anode, just the area around the tip of the cathode ('hotspot') was imaged onto the fiber, to produce the highest intensity output. To compensate for chromatic aberrations, the signal was optimized at each wavelength measured. Output power was measured using 10 nm bandpass interference filters and a calibrated photodetector. These measurements give power at discrete wavelengths across the spectrum, and when linearly interpolated, provide a calibration curve for the lamp. The shape of the spectrum is determined by the collective response of the optics, monochromator, and streak tube across the spectral region of interest. The ratio of the spectral curve to the measured bandpass filter curve at each wavelength produces a correction factor (Q) curve. This curve is then applied to the experimental data and the resultant spectra are given in absolute intensity units (photons/sec/cm{sup 2}/steradian/nm). Error analysis shows this method to be accurate to within +/- 20%, which represents a high level of accuracy for this type of measurement.
Abstract not provided.
This report outlines a convenient method to calibrate fast (<1ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such a system is used to collect spectral data on plasmas generated in the A-K gap of electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA). On RITS, light is collected through a small diameter (200 micron) optical fiber and recorded on a fast streak camera at the output of 1 meter Czerny-Turner monochromator (F/7 optics). To calibrate such a system, it is necessary to efficiently couple light from a spectral lamp into a 200 micron diameter fiber, split it into its spectral components, with 10 Angstroms or less resolution, and record it on a streak camera with 1ns or less temporal resolution.