A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a semiconductor-based atmospheric radioxenon detection system

A prototype radioxenon detection system for beta–gamma coincidence measurements has been designed using a PIPSBox and a pair of coplanar CdZnTe (CZT) detectors. Coincidence events are identified in real-time using a Field-Programmable Gate Array (FPGA). The measurement of 131m Xe and studies on electron backscatter and memory effect in the PIPSBox have been presented previously; this paper details the measurement of 133/133m Xe, 135 Xe, and background. Here, absolute efficiencies were determined, regions of interest were defined, and Minimum Detectable Concentrations (MDC) for all four radioxenon isotopes were calculated. When neglecting interferences between the radioxenons, the prototype system has an estimated MDC of 0.61 ± 0.15 mBq/m 3 for 133 Xe when using gas processing parameters associated with Xenon International, satisfying the CTBTO requirement for sensitivity of ≤1 mBq/m 3 for 133 Xe. Simulation suggests that by increasing number of CZT detectors used by a factor of 16, the MDCs of the system can be improved by a factor of 2-3. The design shows great promise for future improvement and expansion due to its exceptional energy resolution, high background rejection rate, room temperature operation, minimal memory effect, and simple readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A stilbene - CdZnTe based radioxenon detection system

Atmospheric monitoring of radioxenon is one of the most widely used methods by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) to detect elevated levels of 131m Xe, 133/133m Xe, and 135 Xe. The ratios of these radionuclides help discriminate between peaceful use of nuclear technology and nuclear weapon explosions. Radioxenon detection systems often use plastic scintillators in the capacity of an electron detector and a gas cell, plastic gas cells are responsible for introducing high memory effect in these systems. This work presents the design of a new detection system for radioxenon monitoring that utilizes silicon photomultipliers, a stilbene gas cell, and a CdZnTe detector. This detector was evaluated using xenon radioisotope samples produced in the TRIGA reactor at Oregon State University. Here, a 48-h background was collected and calculations of the Minimum Detectable Concentration (MDC) were carried out using the Region of Interest (ROI) approach. An MDC of less than 1 mBq/m 3 was obtained for 131m Xe, 133 Xe, and 133m Xe in accordance with the sensitivity limits set by the CTBTO and performs respectably when compared to state-of-the-art radioxenon detection systems. Using 131m Xe, this study indicates that the stilbene gas cell exhibits a memory effect of 0.045 ±0.017%, this is almost a two-order magnitude improvement compared to plastic scintillators. The main purpose of this work is to explore the use of new stilbene detection media for radioxenon application and addressing the problem of memory effect.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A radioxenon detection system using PIPS and CZT

This paper introduces and describes the initial characterizations of a prototype beta gamma coincidence detection system that utilizes a PIPSBox and two coplanar CdZnTe detectors for atmospheric radioxenon identification and nuclear test ban treaty verification. Coincidences between four independent detecting bodies are identified in real time via a custom coincidence module implemented in a field-programmable gate array (FPGA). The system is compact, maintains simple readout electronics, and provides high resolution radiation detection at room temperature operation. Preliminary measurements using 137 Cs and 131m Xe were conducted to optimize various system parameters to achieve optimal energy resolution of key spectral features. The purpose of this research was to explore the utility of these materials and methods for radioxenon monitoring in the International Monitoring System (IMS).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗