Search NASA⌕ Search

Engineering topics

Gaffney, F. A.

Publications and source records attributed to Gaffney, F. A..

Effects of spaceflight on human calf hemodynamics

Chronic microgravity may modify adaptations of the leg circulation to gravitational pressures. We measured resting calf compliance and blood flow with venous occlusion plethysmography, and arterial blood pressure with sphygmomanometry, in seven subjects before, during, and after spaceflight. Calf vascular resistance equaled mean arterial pressure divided by calf flow. Compliance equaled the slope of the calf volume change and venous occlusion pressure relationship for thigh cuff pressures of 20, 40, 60, and 80 mmHg held for 1, 2, 3, and 4 min, respectively, with 1-min breaks between occlusions. Calf blood flow decreased 41% in microgravity (to 1.15 +/- 0.16 ml x 100 ml(-1) x min(-1)) relative to 1-G supine conditions (1.94 +/- 0.19 ml x 100 ml(-1) x min(-1), P = 0.01), and arterial pressure tended to increase (P = 0.05), such that calf vascular resistance doubled in microgravity (preflight: 43 +/- 4 units; in-flight: 83 +/- 13 units; P < 0.001) yet returned to preflight levels after flight. Calf compliance remained unchanged in microgravity but tended to increase during the first week postflight (P > 0.2). Calf vasoconstriction in microgravity qualitatively agrees with the "upright set-point" hypothesis: the circulation seeks conditions approximating upright posture on Earth. No calf hemodynamic result exhibited obvious mechanistic implications for postflight orthostatic intolerance.

NASA Experiment Number 178294 2/2↗

Measurement of net whole-body transcapillary fluid transport and effective vascular compliance in humans

BACKGROUND: Net whole-body transcapillary fluid transport (TFT) between the circulation and the interstitial (extravascular) space may be calculated as: IV - deltaPV - UV - IL, where IV=infused or ingested volume (when applicable), deltaPV = change in plasma volume, UV=urine volume, and IL=insensible loss. RESULTS: Infusion of 30 mL/kg isotonic saline over 25 minutes increased supine TFT from a basal capillary reabsorption of -106+/-24 mL/h (mean+/-SE) to a net filtration of 1,229+/-124 mL/h. One hour after infusion, reabsorption of -236+/-102 mL/h was seen, and control reabsorption levels returned by 3 hours. Four hours of 30 mm Hg lower body negative pressure (LBNP) elicited no net TFT, probably because of upper body reabsorptive compensation for lower body capillary filtration. When ingestion of 1 L of isotonic saline accompanied LBNP, filtration of 145+/-10 mL/h occurred. Reabsorption of extravascular fluid into the circulation always followed LBNP. CONCLUSION: Application of this technique could aid understanding of physiologic conditions, experimental interventions, disease states, and therapies that cause or are influenced by fluid shifts between intravascular and interstitial compartments.

NASA Center JSC↗

Evidence for increased cardiac compliance during exposure to simulated microgravity

We measured hemodynamic responses during 4 days of head-down tilt (HDT) and during graded lower body negative pressure (LBNP) in invasively instrumented rhesus monkeys to test the hypotheses that exposure to simulated microgravity increases cardiac compliance and that decreased stroke volume, cardiac output, and orthostatic tolerance are associated with reduced left ventricular peak dP/dt. Six monkeys underwent two 4-day (96 h) experimental conditions separated by 9 days of ambulatory activities in a crossover counterbalance design: 1) continuous exposure to 10 degrees HDT and 2) approximately 12-14 h per day of 80 degrees head-up tilt and 10-12 h supine (control condition). Each animal underwent measurements of central venous pressure (CVP), left ventricular and aortic pressures, stroke volume, esophageal pressure (EsP), plasma volume, alpha1- and beta1-adrenergic responsiveness, and tolerance to LBNP. HDT induced a hypovolemic and hypoadrenergic state with reduced LBNP tolerance compared with the control condition. Decreased LBNP tolerance with HDT was associated with reduced stroke volume, cardiac output, and peak dP/dt. Compared with the control condition, a 34% reduction in CVP (P = 0.010) and no change in left ventricular end-diastolic area during HDT was associated with increased ventricular compliance (P = 0.0053). Increased cardiac compliance could not be explained by reduced intrathoracic pressure since EsP was unaltered by HDT. Our data provide the first direct evidence that increased cardiac compliance was associated with headward fluid shifts similar to those induced by exposure to spaceflight and that reduced orthostatic tolerance was associated with lower cardiac contractility.

Non-NASA Center↗

Effect of microgravity on renal and femoral flows during LBNP & intravenous saline load

Renal and femoral hemodynamics were studied in crew members at rest and during lower body negative pressure before and after the D-2 Spacelab mission and with intravenous saline loading. Specific measurements included renal vascular resistance, femoral arterial flow, and vascular resistance, along with other cardiovascular parameters. Cardiovascular adaptation to microgravity is discussed with a focus on changes observed in femoral and renal vascular resistance.

short duration↗

Mechanisms of post-flight orthostatic intolerance

Post-flight orthostatic intolerance is a dramatic physiological consequence of human adaptation to microgravity made inappropriate by a sudden return to 1-G. The immediate mechanism is almost always a failure to maintain adequate tissue perfusion, specifically perfusion of the central nervous system, but vestibular dysfunction may occasionally be the primary cause. Orthostatic intolerance is present in a wide range of clinical disorders of the nervous and cardiovascular systems. The intolerance that is produced by spaceflight and 1-G analogs (bed rest, head-down tilt at a moderate angle, water immersion) is different from its clinical counterparts by being only transiently present in subjects who otherwise have normal cardiovascular and regulatory systems. However, the same set of basic pathophysiological elements should be considered in the analysis of any form of orthostatic intolerance.

Non-NASA Center↗

Cardiovascular adaptation to O-G (Experiment 294) - Instrumentation for invasive and noninvasive studies

Many astronauts returning from space have difficulties regulating blood pressure, some to the point of fainting during quiet standing. Experiment 294 was designed to study this and other cardiovascular effects of adaptation to microgravity and to understand the mechanisms behind it. To accomplish this several cardiovascular variables had to be measured accurately. Heart rate, blood pressure, cardiac output (blood pumped by the heart each minute), stroke volume (blood pumped by the heart with each beat), limb flow, limb compliance, heart size and central venous pressure all had to been recorded during various stresses to understand fully the adaptation to space and the readaptation to earth's gravity. Numerous pieces of equipment were used. Some were purpose-built for the Spacelab mission and others were derived from commercial hardware. Developing spaceflight hardware is challenging and costly, but can lead to significant new information in the unique environment of space.

Buckey, Jay C.↗

Right and left ventricular volumes in vitro by a new nongeometric method

We present an evaluation of a new nongeometric technique for calculating right and left ventricular volumes. This method calculates ventricular chamber volumes from multiple cross-sectional echocardiographic views taken from a single point as the echo beam is tilted progressively through the ventricle. Right and left ventricular volumes are calculated from both the approximate short axis and approximate apical position on 20 in vitro human hearts and compared with the actual chamber volumes. The results for both ventricles from both positions are excellent. Correlation coefficients are > 0.95 for all positions; the standard errors are in the range of 5 to 7 mL and the slopes and intercepts for the regression lines are not significantly different from 1 and 0, respectively (except for the left ventricular short-axis intercept). For all positions, approximately 6 to 8 views are needed for peak accuracy (7.5 degrees to 10 degrees separation). This approach offers several advantages. No geometric assumptions about ventricular shape are made. All images are acquired from a single point (or window), and the digitized points can be used to make a three-dimensional reconstruction of the ventricle. Also, during the calculations a volume distribution curve for the ventricle is produced. The shape of this curve can be characteristic for certain situations (ie, right ventricle, short axis) and can be used to make new simple equations for calculating volume. We conclude that this is an accurate nongeometric method for determining both right and left ventricular volumes in vitro.

NASA Discipline Cardiopulmonary↗

Spacelab Life Sciences flight experiments: an integrated approach to the study of cardiovascular deconditioning and orthostatic hypotension

The microgravity environment of spaceflight produces rapid cardiovascular changes which are adaptive and appropriate in that setting, but are associated with significant deconditioning and orthostatic hypotension on return to Earth's gravity. The rapidity with which these space flight induced changes appear and disappear provides an ideal model for studying the underlying pathophysiological mechanisms of deconditioning and orthostatic hypotension, regardless of etiology. Since significant deconditioning is seen after flights of very short duration, muscle atrophy due to inactivity plays, at most, a small role. These changes in circulatory control associated with cephalad fluid shifts, rather than inactivity per se, are probably more important factors. In order to test this hypothesis in a systematic way, a multidisciplinary approach which defines and integrates inputs and responses from a wide variety of circulatory sub-systems is required. The cardiovascular experiments selected for Spacelab Life Sciences flights 1 and 2 provide such an approach. Both human and animal models will be utilized. Pre- and post-flight characterization of the payload crew includes determination of maximal exercise capacity (bicycle ergometry), orthostatic tolerance (lower body negative pressure), alpha and beta adrenergic sensitivity (isoproterenol and phenylephrine infusions), baroreflex sensitivity (ECG-gated, stepwise changes in carotid artery transmural pressure with a pneumatic neck collar), and responses to a 24 h period of 5 deg head-down tilt. Measurements of cardiac output (CO2 and C2H2 rebreathing), cardiac chamber dimensions (phased-array 2-dimensional echocardiography), direct central venous pressure, leg volume (Thornton sock), limb blood flow and venous compliance (occlusion plethysmography), blood and plasma volumes, renal plasma flow and glomerular filtration rates, and various hormonal levels including catecholamines and atrial natriuretic factor will also be obtained. The central venous catheter will be inserted immediately pre-launch and monitored with heart rate and blood pressure in-flight until cardiac output, respiratory gas exchange and quantitative 2D echocardiography measurements can be performed. In-flight hemodynamic measurements will be repeated at rest and during submaximal exercise daily and also during maximal exercise midway through the flight to document the timecourse and extent of cardiovascular changes in the payload crew. Parallel studies are planned for the animals. In addition to measurements of right atrial and aortic pressures and cardiac output, a dorsal micro-circulatory chamber will allow determinations of changes in capillary and venular architecture and function in six of the rats. The techniques and findings from many of the SLS-1 and 2 supporting studies have already yielded significant information about circulatory regulation in patients with both hypo- and hypertension. The flight experiments themselves will provide new data to test the validity of both animal and human models currently used for simulating the fluid shifts of a micro-gravity environment. The development of effective countermeasures, not only for short and long duration space travellers, but also for Earth-bound medical patients can then be physiologically based on experimental data rather than anecdote.

Non-NASA Center↗

Spacelab life sciences flight experiments - An integrated approach to the study of cardiovascular deconditioning and orthostatic hypotension

A Spacelab experiment to study cardiovascular deconditioning and orthostatic hypotension is proposed. Previous experiments that have attempted to explain the factors which cause alterations in cardiovascular regulation are investigated. Based on these observations a hypothesis which states cephalad fluid shift produces cardiovascular changes is studied. The testing of the hypothesis is to include the analysis of physiological and anatomical changes in humans and animals for preflight and in-flight periods. The procedures and measurement techniques for the experiment are described.

Gaffney, F. A.↗

Cardiac chamber volumes by echocardiography using a new mathematical method: A promising technique for zero-G use

Accurate, reproducible, and non-invasive means for ventricular volume determination are needed for evaluating cardiovascular function zero-gravity. Current echocardiographic methods, particularly for the right ventricle, suffer from a large standard error. A new mathematical approach, recently described by Watanabe et al., was tested on 1 normal formalin-fixed human hearts suspended in a mineral oil bath. Volumes are estimated from multiple two-dimensional echocardiographic views recorded from a single point at sequential angles. The product of sectional cavity area and center of mass for each view summed over the range of angles (using a trapezoidal rule) gives volume. Multiple (8-14) short axis right ventricle and left ventricle views at 5.0 deg intervals were videotaped. The images were digitized by two independent observers (leading-edge to leading-edge technique) and analyzed using a graphics tablet and microcomputer. Actual volumes were determined by filling the chambers with water. These data were compared to the mean of the two echo measurements.

Buckey, J. C.↗

Hemodynamic changes during whole body surface cooling and lower body negative pressure

Six young healthy male subjects were studied to evaluate the use of whole body surface cooling (WBSC) as an antiorthostatic intervention. Previous studies have demonstrated that perfusion of an Apollo cooling garment with 16 C water produced a significant increase in stroke volume and decrease in heart rate at rest and during lower body negative pressure (LBNP). However, optimal perfusion temperatures have not been determined. The present study examined the effects of WBSC using perfusion of water at a temperature of 10 C. This perfusion temperature produced a greater decrease in mean skin temperature than water at 16 C (4 C drop compared to 2 C). The hemodynamic effects were also more prominent with 10 C water as shown by the increase in stroke volume of 11% at rest and of 35% during LBNP at -50 torr compared to control measurements at ambient temperature. Heart rates were lowered significantly (8 beats/min) and systolic arterial blood pressure was higher (8 torr). Cooling with 10 C water produced a slight increase in muscle tone, reflected by a small but significant increase (+84 ml/min) in oxygen uptake. These data suggest that WBSC is an effective nonpharmacologic means of controlling preload and deserves further investigation as an antiorthostatic intervention.

Raven, P. B.↗

Interactions between surface cooling and LBNP-induced central hypovolemia

The paper describes a study carried out to determine the extent to which whole body surface cooling (WBSC) modifies the effects of the central hypovolemia produced by lower body negative pressure (LBNP) at normal skin temperatures. It is shown that WBSC produces a central displacement of cutaneous venous volume resulting in an increase in stroke volume.