Rapid calibration of seven-hole probes

This paper summarizes the major conclusions and some of the key supporting analyses resulting from the calibration and application of two small seven hole probes at NASA Lewis Research Center. These probes can produce reasonably accurate and rapid surveys of unknown steady flow fields which may include flow angles up to 70 degrees and Mach numbers up to 0.8. The probes were calibrated with both 'complete' and 'reduced' test matrices. Both types of test matrices produced similar results suggesting the the reduced matrices are adequate for most purposes. The average accuracy fo the calibration was about the same as that achieved in previous seven hole probe calibrations. At the higher Mach numbers, the calibration was sensitive to the diameter of the free jet in the calibration facility. Over a narrow angular range at the higher Mach numbers, the system had serious repeatability problems. This lack or repeatability apparently results from aliasing of high frequency (20 to 40 Hz) noise with the data acquisition system sampling frequency of 10 Hz. Analyses show that these noise frequencies are probably not related to airflow dynamics in the connecting tubing.

Ericksen, A. L.↗

Non-nulling seven-hole probes for high angle flow measurement

This paper illustrates a method for calibrating seven-hole probes to measure local total and static pressures and relative flow angles of up to 70 degrees in subsonic compressible flows. The method of Latin Squares was used to statistically sample a large and otherwise unmanageable data set, thereby reducing to a minimum the number of data points required to construct a polynomial curve fit to the data. Calibration produces three-variable third order polynomials which permit all of the desired flow properties to be found explicitly from probe measured pressures. This method determines the flow angles to within 2 degrees and Mach number to within 0.04 with 95 percent certainty.

Gerner, A. A.↗

Measurement of very large flow angles with non-nulling seven-hole probes

This paper describes a method for measuring local direction and total and static pressures of a flow by means of a fixed probe, provided that the local air flow does not make an angle of more than 80 degrees with the axis of the probe. The probe is easily manufactured from standard-sized tubing materials. The power series calibration method used with the probe results in explicit polynomial expressions for the desired aerodynamic properties. The calibration method is easily programmed on a data acquisition system. This paper includes an example of a complete incompressible calibration.

Gallington, R. W.↗