Search NASA⌕ Search

Engineering topics

Gang, Wu

Publications and source records attributed to Gang, Wu.

Exposing structural variations in SARS-CoV-2 evolution

The mutation of SARS-CoV-2 influences viral function as residue replacements affect both physiochemical properties and folding conformations. Although a large amount of data on SARS-CoV-2 is available, the investigation of how viral functions change in response to mutations is hampered by a lack of effective structural analysis. Here, we exploit the advances of protein structure fingerprint technology to study the folding conformational changes induced by mutations. With integration of both protein sequences and folding conformations, the structures are aligned for SARS-CoV to SARS-CoV-2, including Alpha variant (lineage B.1.1.7) and Delta variant (lineage B.1.617.2). The results showed that the virus evolution with change in mutational positions and physicochemical properties increased the affinity between spike protein and ACE2, which plays a critical role in coronavirus entry into human cells. Additionally, these structural variations impact vaccine effectiveness and drug function over the course of SARS-CoV-2 evolution. The analysis of structural variations revealed how the coronavirus has gradually evolved in both structure and function and how the SARS-CoV-2 variants have contributed to more severe acute disease worldwide.

59 BASIC BIOLOGICAL SCIENCES↗

Characteristics of implosion and radiation for aluminum planar wire array z-pinch at 1.5 MA

Planar wire arrays Z pinches were carried out on Qiangguang generator (1.5 MA, 100 ns). Loads with varied row widths (6-24 mm) and wire numbers (10-34) were employed in the experiments. The implosion dynamics of planar wire arrays has been studied. Meanwhile, the changes of the implosion time, radiation yield and power with array mass, inter-wire gap, and array width were investigated. The images of a soft X-ray camera exhibit that the trailing mass, precursor column, and R-T instability exist during the implosion phase, and when m = 0 maybe accompanied with m = 1, instability will rapidly develop after stagnation. The implosion trajectories show that loads will implode by the snowplow mode and about 50% of total initial array mass will participate in the final implosion. The maximum total X-ray energy is 22 kJ with a power of 630 GW, while the maximum K-shell yield is 3.9 kJ with a power of 158 GW. Experiments with different planar wire arrays show that the value of m{sub P}D{sub 0}{sup 2} (the product of line mass and squared width) is the critical factor which affects the implosion time and the X-ray products of the wire arrays. The optimum value of m{sub P}D{sub 0}{sup 2} should be in the range of 200-400 {mu}gcm and the inter-wire gap should be less than 1 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral analysis of mammographic images using a multitaper method

Purpose: Power spectral analysis in radiographic images is conventionally performed using a windowed overlapping averaging periodogram. This study describes an alternative approach using a multitaper technique and compares its performance with that of the standard method. This tool will be valuable in power spectrum estimation of images, whose content deviates significantly from uniform white noise. The performance of the multitaper approach will be evaluated in terms of spectral stability, variance reduction, bias, and frequency precision. The ultimate goal is the development of a useful tool for image quality assurance. Methods: A multitaper approach uses successive data windows of increasing order. This mitigates spectral leakage allowing one to calculate a reduced-variance power spectrum. The multitaper approach will be compared with the conventional power spectrum method in several typical situations, including the noise power spectra (NPS) measurements of simulated projection images of a uniform phantom, NPS measurement of real detector images of a uniform phantom for two clinical digital mammography systems, and the estimation of the anatomic noise in mammographic images (simulated images and clinical mammograms). Results: Examination of spectrum variance versus frequency resolution and bias indicates that the multitaper approach is superior to the conventional single taper methods in the prevention of spectrum leakage and variance reduction. More than four times finer frequency precision can be achieved with equivalent or less variance and bias. Conclusions: Without any shortening of the image data length, the bias is smaller and the frequency resolution is higher with the multitaper method, and the need to compromise in the choice of regions of interest size to balance between the reduction of variance and the loss of frequency resolution is largely eliminated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aluminum and tungsten X-pinch experiments on 100 kA, 100 ns linear transformer driver stage

X-pinch experiments have been carried out on a 100 kA, 100 ns linear transformer driver stage recently built up. The X-pinches exhibited a source size of about 10 {mu}m, a pulse duration of 3 ns, 3-5 keV radiation energy of 3.9 mJ, and a burst time jitter of tens of nanosecond with the 2-wire 8 {mu}m W X-pinch load. The generator output current and the X-pinch characteristics depended on the X-pinch wire materials in the tests. X-ray backlighting images from the insects showed the significant phase-contrast effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Syntheses, structures and properties of silver(I) complexes with flexible 1,3,5-tris(pyridylmethoxyl)benzene ligands

Five new silver(I) complexes [Ag{sub 2}(L{sub 2}){sub 2}](BF{sub 4}){sub 2}.CH{sub 3}CN.CH{sub 3}OH (1), [Ag(L{sub 2})(CF{sub 3}SO{sub 3})] (2), [Ag(L{sub 3})]ClO{sub 4}.CH{sub 3}OH (3), [Ag{sub 2}(L{sub 3}){sub 2}](CF{sub 3}SO{sub 3}){sub 2}.CH{sub 3}CN.CH{sub 3}OH.H{sub 2}O (4) and [Ag(L{sub 3})]PF{sub 6}.2CH{sub 3}CN (5) [L{sub 2}=1,3,5-tris(2-pyridylmethoxyl)benzene, L{sub 3}=1,3,5-tris(3-pyridylmethoxyl)benzene] were synthesized and characterized by single crystal X-ray diffraction analyses. In complexes 1-5, ligands L{sub 2} and L{sub 3} show different conformations and act as three-connectors, while the Ag(I) atom serves as three-connecting node to result in the formation of 2D and 3D frameworks. Complexes 1 and 2 with different counteranions have similar 2D network structure with the same (4,8{sup 2}) topology. Complex 3 has a 3D structure with (10,3)-a topology while complexes 4 and 5 have the same 2D (6,3) topological structure. The results showed that the structure of organic ligands and counteranions play subtle but important role in determining the structure of the complexes. In addition, the photoluminescence and anion-exchange properties of the complexes were investigated in the solid state at room temperature. - Graphical abstract: Five new silver(I) coordination frameworks with different topology were obtained and their structures were determined by single crystal X-ray diffraction studies. The influence of counteranion and ligand on the structure of complexes was discussed, the photoluminescence and anion-exchange properties were reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of scatter effects on image quality for breast tomosynthesis

Digital breast tomosynthesis uses a limited number (typically 10-20) of low-dose x-ray projections to produce a pseudo-three-dimensional volume tomographic reconstruction of the breast. The purpose of this investigation was to characterize and evaluate the effect of scattered radiation on the image quality for breast tomosynthesis. In a simulation, scatter point spread functions generated by a Monte Carlo simulation method were convolved over the breast projection to estimate the distribution of scatter for each angle of tomosynthesis projection. The results demonstrate that in the absence of scatter reduction techniques, images will be affected by cupping artifacts, and there will be reduced accuracy of attenuation values inferred from the reconstructed images. The effect of x-ray scatter on the contrast, noise, and lesion signal-difference-to-noise ratio (SDNR) in tomosynthesis reconstruction was measured as a function of the tumor size. When a with-scatter reconstruction was compared to one without scatter for a 5 cm compressed breast, the following results were observed. The contrast in the reconstructed central slice image of a tumorlike mass (14 mm in diameter) was reduced by 30%, the voxel value (inferred attenuation coefficient) was reduced by 28%, and the SDNR fell by 60%. The authors have quantified the degree to which scatter degrades the image quality over a wide range of parameters relevant to breast tomosynthesis, including x-ray beam energy, breast thickness, breast diameter, and breast composition. They also demonstrate, though, that even without a scatter rejection device, the contrast and SDNR in the reconstructed tomosynthesis slice are higher than those of conventional mammographic projection images acquired with a grid at an equivalent total exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗