Study of Seamless Microgrid Transition Operation Using Grid-Forming Inverters

This paper investigates operational techniques to achieve seamless (smooth) microgrid (MG) transitions by dispatching a grid-forming (GFM) inverter. In traditional approaches, the GFM inverter must switch between grid-following (GFL) and GFM control modes during MG transition operation. Today's inverter technology allows GFM inverters to always operate in GFM control mode, so it is worth exploring how to use them to achieve smooth MG transition operation. This paper proposes three operational techniques: a traditional scheme of switching between GFL and GFM control; a new scheme of consistent GFM control and shifting the droop intercept up before islanding operation; and a new scheme of consistent GFM control and shifting the droop intercept up before synchronization operation. A full hardware setup is established to compare the three techniques and showcase their implementations in real-world applications. The results show that the third technique outperforms the others and exhibits the best transition performance because the GFM inverter maintains the same operating points during the transition operation. Therefore, we conclude that ensuring smooth MG transition operation requires that the GFM inverter(s) maintain the same operating points (v, f, P, Q, and phase angle) during the transition operation in addition to minimizes the point of common coupling power flow.

grid-forming↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters: Preprint

Smart inverters (SI) have huge potential in providing grid services which has not been fully realized yet. One of these grid services, distribution network voltage regulation by SI, can improve the network voltage by regulating the SI reactive and active power output. Voltage regulation by SI is much faster compared to traditional voltage regulating devices, e.g. tap changing transformer, capacitor banks. However, there is gap in available published literature on the characteristics of SIs when the SI is controlled by local controller or external control signal. This paper presents the experimental study to characterize SI reactive power regulation response to two different control methods: autonomous control method and remote dispatch method. It was found that IS reactive power regulation response could be significantly different in terms of delay, and ramp rate for these two methods. Finally, Power-Hardware-in-The-Loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL tests results show that SI response characteristics for autonomous control method and remote dispatch method need to be considered during planning for distribution network voltage regulation using SI.

autonomous control↗