Development of a Structure for Lossless Ion Manipulations (SLIM) High Charge Capacity Array of Traps

Enhancing the sensitivity of low abundance ions in a complex mixture without sacrificing experiment throughput is highly desirable. This work demonstrates a way to greatly improve the sensitivity of ion mobility (IM) selected ions by accumulating them in an array of high-capacity ion traps located inside a novel structures for lossless ion manipulations ion mobility spectrometer (SLIM-IMS) module. The array of ion traps used in this work consisted of seven independently controllable traps. Each trap was 386 mm long and possessed a charge capacity of ~4.5×10 8 charges, with a linear range extending to ~2.5×10 8 charges. Each ion trap could be used to extract a peak (or ions over a mobility range) from an ion mobility separation based on arrival time. Ions could be stored without losses for long times (>100 s) and then released all at once or one trap at a time. It was possible to accumulate large ion populations by extracting and storing ions over repeated IM separations. We report enrichment of up to seven individual ion distributions could be performed using the seven independently controllable ion traps. Additionally, the ion trapping process effectively compressed ion populations into narrow peaks, which provides a greatly improved basis for subsequent ion manipulations. The array of high charge-capacity ion traps provides a flexible addition to SLIM and a powerful tool for IMS-MS applications requiring high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric pressure ion focusing device employing nonlinear DC voltage sequences

Apparatus comprise an electrode arrangement comprising a plurality of electrodes defining a volume, an ion entrance, and an ion exit, and a voltage source coupled to the plurality of electrodes and configured to apply a nonlinear DC voltage sequence to the electrodes between the ion entrance and the ion exit that directs ions through the volume with the volume at a pressure of at least 1 Torr. Ions can be focused using nonlinear DC voltage sequences, including at atmospheric pressure. Related methods are also disclosed.

Hollerbach, Adam L.↗

Frequency modulated radio frequency electric field for ion manipulation

A method of manipulating ions comprises injecting ions between a first surface and a second surface positioned parallel to and spaced apart from each other and defining a central axis therebetween, wherein the first surface comprises first outer electrodes coupled to the first surface and a first inner array of electrodes coupled to the first surface and positioned between the first outer electrodes, wherein the second surface comprises second outer electrodes coupled to the second surface and a second inner array of electrodes coupled to the second surface and positioned between the second outer electrodes, and applying a frequency modulated RF voltage to at least one electrode of the first inner array of electrodes or the second inner array of electrodes to confine ions between the first surface and the second surface and to guide ions between the first surface and the second surface along the central axis.

42 ENGINEERING↗

Rapid and Simultaneous Characterization of Drug Conjugation in Heavy and Light Chains of a Monoclonal Antibody Revealed by High-Resolution Ion Mobility Separations in SLIM

Antibody-drug conjugates (ADCs) have recently gained traction in the biomedical community due to their promise for human therapeutics and an alternative to chemotherapy for cancer. Crucial metrics for ADC efficacy, safety, and selectivity are their drug-antibody ratios (DARs). However, DAR characterization (i.e., determining the average number of conjugated drugs on the antibody) through analytical methods remains challenging due to the heterogeneity of drug conjugation as well as the numerous post-translational modifications possible in the monoclonal antibody. In this work, we report on the use of high-resolution ion mobility spectrometry separations in our structures for lossless ion manipulations coupled to mass spectrometry (SLIM IMS-MS) platform for the rapid and simultaneous characterization of the drug load profile (i.e., stoichiometric distribution of the number of conjugated drugs present on the mAb), determination of the weighted average DAR in both the heavy and light chains of a model antibody-drug conjugate, and calculation of the overall DAR of the ADC. After chemical reduction of the ADC and a subsequent 31.5 meter SLIM IMS separation the various drug bound antibody species could be well resolved for both chains. Furthermore, we also show that higher resolution separations were possible with SLIM IMS as compared to ones performed on a commercially available (~1 meter) drift tube IMS-MS platform. Interestingly, additional gas-phase substructures become evident with longer path length SLIM IMS, potentially providing insight related to how drug conjugation may alter the structural properties of a monoclonal antibody and thus affect its overall potency and/or selectivity for a given antigen. We expect high-resolution SLIM IMS separations will augment the existing toolbox for ADC characterization, particularly for structural confirmation to enable the rapid optimization of DAR for a given ADC and thus better understand its potential toxicity and potency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗