Search NASA⌕ Search

Engineering topics

Garimella, Srinivas

Publications and source records attributed to Garimella, Srinivas.

At least 19 records

Radio Frequency Calcination of Gypsum for Sustainable Wallboard Production

This presentation details several accomplishments in the dielectric calcination of gypsum to stucco. 1) Verification that gypsum can be calcined via RF heating, 2)Characterization of heating and mass loss curve for a nucleation propagation reaction under electromagnetics 3) Full parametric studies examining effect of free moisture on heating and calcination, and 4) Finite element model of process with high predictive capability. Overall, Industrial implementation could save up to 63% energy, 50% water, and reduce carbon emissions by 63% based on batch scale studies.

Tjards, Jacob↗

A whole-core steady-state thermal-hydraulic model for annular fuel type fluoride-salt-cooled reactors

A whole-core, steady-state thermal-hydraulic model is developed for the fluoride-salt-cooled small modular advanced high-temperature reactor (SmAHTR) that employs an annular fuel configuration. This pre-conceptual reactor design by Oak Ridge National Laboratory (ORNL) has the annular fuel and moderator pins arranged in a hexagonal layout. The FLiBe coolant flows from the bottom to the top of the core, parallel to the hexagonal bundle. The fuel and moderator pins in the core are discretized into finite volumes and the 3-D heat conduction equation is solved to obtain the temperature profile. Inter-fuel assembly conduction is also addressed. For this fuel assembly configuration, the coolant flows through two distinct regions – the hexagonal pin bundle and the annulus between the fuel pin and the tie rod. The fluid flow through the hexagonal bundles is modeled using the subchannel approach, in which the coolant region is discretized into corner, edge and interior subchannels and the resulting conservation equations are systematically solved. The 1-D mass, momentum and energy equations are solved for the annulus channels between the fuel pin and the tie rod. Pertinent closure models from the literature are employed to close the system of equations. We also performed a preliminary code-to-code comparison between the present model and a CFD model.. The resulting thermal-hydraulic model can provide temperature, flow rate and pressure drop profiles for the different solid and fluid regions throughout the entire core. Whole-core thermal-hydraulic results for a representative power profile are presented and discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CFD analysis of a solid pin-fueled small modular fluoride salt-cooled reactor

A computational fluid dynamics (CFD) study is performed for the pre-conceptual solid pin-fueled small modular fluoride salt-cooled reactor developed by the Oak Ridge National Laboratory (ORNL). The solid and fluid regions in a 1/12th section of a fuel assembly are modeled. The solid region includes fuel and non-fuel pins, with heat generation in the active region of the fuel pins. Two different power profiles, uniform and center-peaked, are considered. The FLiBe coolant flows from the bottom to the top of the core, parallel to the bank of fuel and non-fuel pins. The k-ω shear-stress transport (SST) model is chosen as the baseline turbulence model. The effects of grid refinement, inlet turbulence specification, and turbulence models on the temperature and pressure drop predictions are studied. Turbulence model sensitivity is investigated by comparing the results from the k-ω SST model with other two-equation models (k-ω baseline or BSL and k-ε realizable) as well as with anisotropic Reynolds stress transport models (linear pressure-strain and stress-BSL). Here the results show that the choice of turbulence model has a significant impact on the pin temperature and bundle pressure drop predictions. The results from the baseline turbulence model show good agreement between the fuel pin temperatures and bundle pressure drop values predicted using a subchannel model previously developed by the authors of the present study.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗

A microchannel shell-and-tube absorber for ammonia-water absorption

A shell-and-tube absorber with microscale geometric features that yields significant volumetric heat duties is investigated. A vertically-oriented baffled shell-and-tube heat exchanger with a tightly packed tube bundle is designed to serve as the absorber for a 10.5 kW nominal cooling capacity absorption chiller. The heat and mass transfer in this absorber is investigated experimentally at operating conditions spanning a wide range of working fluid and coupling fluid flow rates and ambient temperatures. An experimental facility is fabricated to closely simulate the operating conditions in an absorption refrigeration system. Absorption heat duties in the range of 5-15 kW are measured. In addition to operating the absorber in the baseline co-current flow configuration with premixed inlet, fluid ports are provided to enable operation in counter-current flow, where the dilute solution enters from the top and vapor enters from the bottom. The performance of these two flow configurations is compared. A preliminary heat and mass transfer model is developed to quantify the local temperatures, concentrations, and mass flow rates of the solution and vapor streams along the length of the absorber. The model predictions for total heat duty agree with the experimental results within 10% for almost all the data points, with an AAD of ~3.4%. Finally, the results of this study, along with the modeling framework, can guide further development of highly compact and efficient absorbers absorption systems.

42 ENGINEERING↗

Novel geometries for air-cooled condensation of ammonia-water mixtures

An analytical and experimental investigation of air-cooled condensers for small-scale ammonia-water absorption heat pumps is presented. Conventional round-tube corrugated fin design and a novel multi-pass tube array design are considered for a condenser operating at severe ambient conditions within a compact footprint. Segmental heat and mass transfer models are developed to gain a deeper understanding of the characteristics of each design. Predicted heat duties are within 5% of the measured values. The limitations of correlations to predict air-side pressure drop in corrugated fins are identified. The performance of the novel multi-pass tube array condenser was comparable to that of conventional condensers, but is determined to be air-side limited throughout length of the heat exchanger. An improved multi-pass condenser design with fins for increased air-side area is proposed using the insights gained from the modeling and experiments. In closing this design meets the heat duty requirements at severe ambient conditions, while decreasing the size of the heat exchanger by 33%.

42 ENGINEERING↗

I 2 S-LWR microchannel heat exchanger design and experimental validation

The Integral Inherently Safe Light Water Reactor (I 2 S-LWR) includes primary-to-secondary coolant heat exchangers located in the downcomer of the reactor pressure vessel. A microchannel heat exchanger (MCHX) configuration is selected to meet the limited available volume and high heat duty requirements. The design, modeling, and optimization of the liquid-liquid MCHX is outlined. In addition, the performance of a MCHX test section representative of the I 2 S-LWR MCHX design is validated experimentally. Experimental results show that heat transfer and pressure drop correlations developed for larger, macroscale channels lead to accurate predictions of performance. Additionally, this study shows that an MCHX can deliver the required heat duties within the available space and pressure drop constraints of the overall I2 S-LWR design.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of fouling mechanisms for diesel engine exhaust heat recovery

The effect of diesel engine exhaust fouling on heat and mass exchangers for waste heat recovery is investigated. Experiments are conducted for a range of operating conditions relevant to the use of the waste heat from a diesel engine for powering a 2.71 kW capacity absorption heat pump. Thermal resistances of fouling layers as well as their effects on pressure drop are determined, and the underlying mechanisms for deposition and removal are investigated. Fouling layer effects are most severe for the lowest coolant temperatures and 100% generator load. At these conditions, the fouling thermal resistance is approximately 70% of the total resistance, and the ratio of the steady-state pressure drop to the baseline pressure drop is 3.25. Flow induced shear is found to be the primary growth inhibiting mechanism at high exhaust velocities. Findings from this study can guide heat exchanger design for a variety of waste heat recovery systems.

04 OIL SHALES AND TAR SANDS↗

Diesel Engine Waste Heat Driven Absorption Heat Pumps for ECU Applications in Defense Installations

A thermally activated absorption heat pump suitable for use in naval expeditionary Environmental Control Units, as well as residential space-conditioning, is developed. Waste heat characteristic of the exhaust stream from a diesel engine GenSet is used to drive an absorption cycle to provide cooling. The heat source is coupled to the heat pump using an intermediate fluid loop for flexible deployment. With minor modifications, the heat pump could also provide heating at high coefficients of performance, resulting in versatile functionality. This technology capitalizes on heat and mass transfer enhancement possible in microscale passages to provide a compact architecture for the components and the overall system. The working fluid pair with zero Global Warming Potential is contained within this assembly, reducing fluid inventories significantly over conventional systems. Quiet, reliable, long-life operation due to the absence of a compressor and the use of few moving parts are further critical distinguishing advantages. Modularity in cooling capacity has been demonstrated through scaling-up of component geometry and internal features and dimensions. The core technology was initially demonstrated with a proof-of-concept microscale absorption chiller measuring 200 × 200 × 34 mm and weighing 7 kg that delivered 300 W of cooling in laboratory tests. In the previous BEETIT project, the team made significant advances over the proof-of-concept. System and component designs with > 10× scale-up in capacity were developed, in a packaged unit capable of standalone operation with a semi-autonomous control system. A cooling capacity of 3.5 kW with a COP > 0.5 at an ambient temperature of 35°C was demonstrated for this natural gas-fired unit. Significant cost reductions in fabrication were achieved using low-cost brazing instead of diffusion bonding. In companion projects funded by the Southern Company and the Georgia Research Alliance, stamping and fluid forming techniques were investigated to fabricate microscale features instead of photochemical etching, thereby leading to significant cost reductions. In a follow-on effort funded by ARPA-E and NAVFAC, a 2.7 kW cooling unit was developed to provide cooling at a severe ambient condition of 51.7°C. The unit was driven directly by diesel engine exhaust heat. Innovative finned heat and mass exchangers for the ambient-coupled condenser and absorber were developed. In the present effort, a standalone, packaged and controllable 10.5 kW cooling capacity absorption chiller is developed. This demonstrates a 30× scale up from the proof-of-concept, thus validating the scalability of microchannel heat exchangers for absorption heat pumps. Autonomous operation algorithms demonstrated enhanced dynamic performance. The knowledge from previous projects was leveraged to develop novel component designs that further helped in miniaturizing the heat exchangers. All coupling fluids are hydronically coupled to aid flexible field deployment. The prototype unit provides design cooling capacity at high ambient temperature conditions of 44°C at COP > 0.6.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accurate and inexpensive thermal time-of-flight sensor for measuring refrigerant flow in minichannels

Thermal flow meters are good candidates for measuring flow rates in small diameter channels because they can be integrated into compact geometries and consist of only a few simple components. A new thermal time-of-flight (TOF) flow sensor is developed in this report for measuring liquid refrigerant velocities in minichannels. The sensor consists of a small heater and two downstream thermocouples. The heater is pulsed to induce a temperature rise in the fluid, and the time for the temperature pulse to reach the downstream thermocouples is measured. Insights from the data and a simplified one-dimensional transient model are used to calibrate the device. The calibration relates the time of flight to both the average refrigerant velocity and local temperature gradients in the fluid. The calibrated TOF device can detect refrigerant velocities between 1 and 20, mm s -1 , measuring 98.7% of the data to within ±3% of the full scale (±0.6 mm s -1 ).

42 ENGINEERING↗

A data driven control strategy for optimal and flexible operation of absorption systems; Stratégie de régulation fondée sur les données pour un fonctionnement optimal et flexible des systèmes à absorption

A novel control strategy for vapor absorption systems with experimental validation is presented. Statistical methods are used to integrate a detailed thermodynamic model and system-specific characteristics into a model based control algorithm. This allows for continuously optimized operation as well as fast response to variations in operating conditions. Autonomous controller performance was tested experimentally for response to changes in heat sink and evaporator temperatures. Continuous turndown with fast response to capacity demand changes, in contrast to suboptimal on/off control, was demonstrated. The thermal compressor concept was employed to develop the variable speed thermal compressor module, with aspects specific to absorption heat pumps, also facilitating cross-applicability of vapor compression system control strategies. Our results of this study enable further development and optimization of absorption systems for a wide range of applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗