Stacked Greenfield and Brownfield ROZ Fairways in the Illinois Basin Geo-Laboratory: Co-Optimization of EOR and Associated CO 2 Storage

Residual oil zones (ROZs) are economically viable targets for carbon dioxide enhanced oil recovery (CO 2 -EOR); thick, carbonate ROZs in the San Andres Formation in the Wasson Field of the Permian Basin are an example. Incremental oil produced from CO 2 -EOR can be carbon negative via associated storage of injected CO 2 . Given the regional extent of ROZ fairways and generally higher net utilization of CO 2 (compared to conventional CO 2 -EOR), ROZs provide the opportunity for significant carbon neutral to carbon negative oil production with associated CO 2 storage, and therefore should be a priority target for exploration. However, ROZs have not been widely recognized or identified due to poor or no conventional oil production. Hence, in places like the Illinois Basin (ILB), exploratory analyses are required to recognize the existence of an ROZ. As part of this study, four formations were selected for detailed regional characterization and analysis: Carper Sandstone (part of the Borden Siltstone), Tar Springs Sandstone, Cypress Sandstone, and Middle Devonian (Geneva Dolomite and associated Dutch Creek Sandstone). The four formations underwent regional geological characterization to develop a regional geologic framework for the ROZs and their overlying seals. Findings of this study are supported by data from two field laboratory sites, one with stacked greenfield ROZs and the other with a stacked complex that includes a brownfield ROZ and depleted conventional reservoirs. The field laboratory sites were used to collect data and conduct tests to validate ROZ detection methodologies and identify economic field-deployable strategies to co-optimize CO 2 -EOR and associated storage in stacked ROZs. Findings from these field sites were extrapolated to characterize the basin-wide stacked ROZ fairway resource.

01 COAL, LIGNITE, AND PEAT↗

Geothermal Heat Recovery Complex: Large-Scale, Deep Direct-Use System in a Low-Temperature Sedimentary Basin (Final Report)

A feasibility study of using deep direct-use (DDU) geothermal energy to heat agricultural research facilities (ARFs) was conducted at the University of Illinois at Urbana-Champaign (U of IL) and its similar application to military facilities in the Illinois Basin (ILB). The geothermal energy system (GES) investigated utilizes low-temperature (30–90°C; 90–190°F) geothermal fluid (i.e., brine) from an extraction well that is part of a deep, two-well (doublet) system that extends to the bottom of the ILB. The geothermal reservoir modeled, the Mt. Simon Sandstone (MSS), is about 1,280 m (4,200 feet) deep and 457 m thick (1,500 feet) beneath the U of IL. The DDU GES surface infrastructure includes heat exchangers connected in-parallel to pipelines carrying the geothermal fluid and fresh cold and hot water. Analysis of the GES indicated that the MSS can provide a baseload of 2 MMBtu/hr to heat the ARFs by extracting 954 m³/d (6,000 barrels/day [bbl/d]) of geothermal fluid that has a temperature of 44–46 °C (111–115 °F). In addition to analyzing the levelized cost of heat (LCOH) and life cycle costs, the environmental effects of the DDU GES were evaluated, including reduced greenhouse gas (GHG) emissions and water consumption. Multiple system designs were evaluated and then ranked based on their maximum heating performance, energy efficiency, and cost recovery. This feasibility study identified the key components of the fully-integrated DDU technology that can be implemented, both technically and economically. The results and information from this study provides end-users and policy makers with guidance for additional research on the specific components of DDU technology such that its widespread use can provide an uninterruptible energy source, increase resilience from extreme weather conditions, reduce U.S. dependency on fossil fuels, and reduce greenhouse gas (GHG) emissions. The site-specific part of this study gives U of IL administrators a realistic and pragmatic assessment of the financial resources necessary to add a DDU GES in the MSS to the campus’ energy portfolio.

15 GEOTHERMAL ENERGY↗

Screening and Selection of Illinois Basin ROZs for Resource Assessment

This report summarizes the efforts to screen the seven candidate formations as well as the selection of three formations (Carper Sandstone [part of Borden Siltstone], Tar Springs Sandstone, and Geneva Dolomite/Dutch Creek Sandstone) for further characterization and detailed analysis.

02 PETROLEUM↗

Data Gap Assessment Subtask 4.1 Topical Report

Data sets were compiled and assessed for the Cambro-Ordovician Storage Complex across the CarbonSAFE Illinois East Sub-Basin study area to assess the data needs to support drilling a stratigraphic borehole at the East Sub-Basin case study site located at the Wabash Integrated Gasification Combined Cycle (IGCC) plant north of Terre Haute, Indiana. Available data for the Mt. Simon Sandstone, within a 50 mile range in the East Sub-Basin study area, was assembled and cataloged. A summary of regional data documenting seal penetrations in the Cambrian Eau Claire and Ordovician Maquoketa was compiled, but a lack of deep well control over the project area illustrates the need for test boring and data acquisition at the East Sub-Basin case study site.