Measurement of the total cross section of gold-gold collisions at square too [sNN] = 200 GeV
N/A
High energy Coulomb-scattered electrons for relativistic particle beam diagnostics
Not Available
Physical design of magnetic shielding for LEReC cooling section
The goal of this note is to set basic parameters for the magnetic shielding of LEReC CS with required design attenuation. We considered physical design of magnetic shielding of LEReC cooling section. The schematic of this design along with the list of its basic parameters is shown. We are planning to use 2 layers of 1 mm thick cylindrical mu-metal shields with μ=11000. The radius of the first layer sitting on top of vacuum chamber is 63.5 mm. The second layer radius is 150 mm. Such shielding guarantees adequate transverse angles of electron beam trajectory in the CS.
First beam commissioning at BNL ERL SRF Gun
The 704 MHz SRF gun successfully generated the first photoemission beam in November of 2014. The configurations of the test and the sub-systems are described.The latest results of SRF commissioning, including the cavity performance, cathode QE measurements, beam current/energy measurements, are presented in the paper.
RHIC Prefire Protection Masks
The protection of the RHIC experimental detectors from damage due to beam hitting close upstream elements in cases of abort kicker prefires requires some dedicated precautionary measures with two general options: to bring the beam close to a limiting aperture (i.e. the beam pipe wall), as far upstream of the detector components as possible or, alternatively, to bring a limiting aperture close to the circulating beam. During the FY 2014 RHIC Heavy Ion run the first option was chosen because of the limited time available for preparation before the start of the run. For future runs the second option, in this case the installation of dual-sided movable masks, is preferred. The installation of the masks, one per ring, is planned before the start of the FY 2015 run.
Residual Gas Fluorescence Monitor for Relativistic Heavy Ions at RHIC
N/A
Depressed electron collector for the Gatling Gun Test Stand
An optical solution for, and the general design of an electron collector (EC) for a Gatling gun Test Stand are described. The purposes of this development were to reduce the power load on the electron gun’s high-voltage power supply, and to eliminate the back-streaming of electrons from the dump into the ultra-high-vacuum region of the beam line and the gun chamber, thereby preventing vacuum degradation. The challenge is solved by creating an effective biased “black box” on the cathode terminal for all electrons, and by assuring the vacuum separation of the EC’s volume from the beam line.
Simulation and optimization of multi-slit based emittance measurement for BNL ERL
N/A
The Cathode Preparation Chamber for the DC High Current High Polarization Gun
N/A
Instrumentation for the proposed low energy RHIC electron Cooling project