Search NASA⌕ Search

Engineering topics

Gatu Johnson, M. (ORCID:0000000223831275)

Publications and source records attributed to Gatu Johnson, M. (ORCID:0000000223831275).

Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

Instruments & Instrumentation↗

Characterization of the image plate multi-scan response to mono-energetic x-rays

Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.

Instruments & Instrumentation↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

The impact of low-mode symmetry on inertial fusion energy output in the burning plasma state

Indirect Drive Inertial Confinement Fusion Experiments on the National Ignition Facility (NIF) have achieved a burning plasma state with neutron yields exceeding 170 kJ, roughly 3 times the prior record and a necessary stage for igniting plasmas. The results are achieved despite multiple sources of degradations that lead to high variability in performance. Results shown here, for the first time, include an empirical correction factor for mode-2 asymmetry in the burning plasma regime in addition to previously determined corrections for radiative mix and mode-1. Analysis shows that including these three corrections alone accounts for the measured fusion performance variability in the two highest performing experimental campaigns on the NIF to within error. Here we quantify the performance sensitivity to mode-2 symmetry in the burning plasma regime and apply the results, in the form of an empirical correction to a 1D performance model. Furthermore, we find the sensitivity to mode-2 determined through a series of integrated 2D radiation hydrodynamic simulations to be consistent with the experimentally determined sensitivity only when including alpha-heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inferences of hot electron preheat and its spatial distribution in OMEGA direct drive implosions

Hot electrons generated from laser plasma instabilities degrade performance of direct drive implosions by preheating the deuterium and tritium (DT) fuel resulting in early decompression and lower areal densities at stagnation. A technique to quantify the hot electron preheat of the dense DT fuel and connect it to the degradation in areal density is described in detail. Hot electrons are measured primarily from the hard x-rays they emit as they slow down in the target. The DT preheat is inferred from a comparison of the hard x-ray signals between a DT-layered implosion and its mass equivalent ablator only implosion. The preheat energy spatial distribution within the imploding shell is inferred from experiments using high Z payloads of varying thicknesses. It is found that the electrons deposit their energy uniformly throughout the shell material. For typical direct-drive OMEGA implosions driven with an overlapped intensity of ∼9·1014 W/cm2, approximately ∼0.02%–0.03% of the laser energy is converted into preheat of the stagnated fuel which corresponds to areal density degradations of 10%–20%. The degradations in areal density explain some of the observed discrepancies between the simulated and measured areal densities.

Christopherson, A. R. (ORCID:000000033578635X)↗

Knock-on deuteron imaging for diagnosing the morphology of an ICF implosion at OMEGA

Knock-on deuteron imaging is a new diagnostic technique that is being implemented at the OMEGA laser facility to diagnose the morphology of an inertial confinement fusion (ICF) implosion. It utilizes the fact that some of the neutrons from deuterium–tritium (DT)-fusion reactions generated in the central hot-spot of an ICF implosion elastically scatter deuterons as they traverse the surrounding shell layer. The energy of these “knock-on” deuterons depends on the scattering angle, where the most energetic deuterons are forward-scattered and probe the shape of the central hot-spot, while lower-energy deuterons are made by side-scattering or slowing down in the fuel and carry information about the distribution of the dense DT-fuel layer surrounding the hot-spot. The first proof-of-concept tests have been conducted successfully. In these tests, three penumbral imagers with different views on an implosion recorded deuterons scattered from the dense shell of DT-gas-filled deuterated plastic shell implosions with prescribed offsets. Data from these experiments are presented here, along with novel analysis techniques that iteratively reconstruct the deuteron source from the data. Reconstructed hot-spot and shell radii agree with 1D hydro simulations and indicate a P1 asymmetry in the direction of the offset. A comparison of coaxial deuteron and x-ray images suggests the presence of a mix between the hot-spot and shell on the order of 15 μm. This new diagnostic capability will allow us to study asymmetries in unprecedented detail at OMEGA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Burning plasma achieved in inertial fusion

Obtaining a burning plasma is a critical step towards self-sustaining fusion energy. A burning plasma is one in which the fusion reactions themselves are the primary source of heating in the plasma, which is necessary to sustain and propagate the burn, enabling high energy gain. After decades of fusion research, here we achieve a burning-plasma state in the laboratory. These experiments were conducted at the US National Ignition Facility, a laser facility delivering up to 1.9 megajoules of energy in pulses with peak powers up to 500 terawatts. We use the lasers to generate X-rays in a radiation cavity to indirectly drive a fuel-containing capsule via the X-ray ablation pressure, which results in the implosion process compressing and heating the fuel via mechanical work. The burning-plasma state was created using a strategy to increase the spatial scale of the capsule through two different implosion concepts. These experiments show fusion self-heating in excess of the mechanical work injected into the implosions, satisfying several burning-plasma metrics. Additionally, we describe a subset of experiments that appear to have crossed the static self-heating boundary, where fusion heating surpasses the energy losses from radiation and conduction. These results provide an opportunity to study α-particle-dominated plasmas and burning-plasma physics in the laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A second order yield-temperature relation for accurate inference of burn-averaged quantities in multi-species plasmas

Measured yields and ion temperatures inferred from the fusion product energy spectra can be used as metrics for the performance of an ICF implosion. This can be used to infer species separation, thermal decoupling, flows, or other effects that can cause the inferred ion temperatures to deviate from the true underlying thermal temperature and the yield ratio to deviate from the expected value. Direct inference of the impact of these effects on observed temperatures and yields can be difficult to uncover due to the underlying dependence on the shape and time evolution of the temperature and density profiles of the fusing plasma. Due to differences in the temperature dependence of the reactivities, different fusion products are emitted from different regions and times within the implosion. In order to properly account for this, a second-order analytical expression relating the apparent temperatures and yield ratios is developed. This expression can be coupled to models of yield and/or temperature altering effects to infer their burn-averaged impact on an implosion. The second-order expression shows significant improvement over lower-order expressions in synthetic data studies. Demonstrations of its applications to synthetic data coupled with models of ion thermal decoupling and radial flows are presented. In the case of thermal decoupling, both first and second-order expressions show reasonable levels of accuracy. To consistently infer the amplitude of radial flow with a <10% error, the second-order equation is required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗