Search NASA⌕ Search

Engineering topics

Gaugler, R. E.

Publications and source records attributed to Gaugler, R. E..

32 records · Page 2

TACT1, a computer program for the transient thermal analysis of a cooled turbine blade or vane equipped with a coolant insert. 1. Users manual

A computer program to calculate transient and steady state temperatures, pressures, and coolant flows in a cooled, axial flow turbine blade or vane with an impingement insert is described. Coolant side heat transfer coefficients are calculated internally in the program, with the user specifying either impingement or convection heat transfer at each internal flow station. Spent impingement air flows in a chordwise direction and is discharged through the trailing edge and through film cooling holes. The ability of the program to handle film cooling is limited by the internal flow model. Sample problems, with tables of input and output, are included in the report. Input to the program includes a description of the blade geometry, coolant supply conditions, outside thermal boundary conditions, and wheel speed. The blade wall can have two layers of different materials, such as a ceramic thermal barrier coating over a metallic substrate. Program output includes the temperature at each node, the coolant pressures and flow rates, and the inside heat-transfer coefficients.

Gaugler, R. E.↗

A computer program for the transient thermal analysis of an impingement cooled turbine blade

A computer program to calculate transient and steady state temperatures, pressures, and coolant flows in a cooled turbine blade or vane with an impingement insert is described. Input to the program includes a description of the blade geometry, coolant supply conditions, outside thermal boundary conditions and wheel speed. Coolant-side heat transfer coefficients are calculated internally in the program, with the user specifying the mode of heat transfer at each internal flow station. Program output includes the temperature at each node, the coolant pressures and flow rates, and the inside heat transfer coefficients. A sample problem is discussed.

Gaugler, R. E.↗

A computer program for the transient thermal analysis of an impingement cooled turbine blade

A computer program to calculate transient and steady state temperatures, pressures, and coolant flows in a cooled turbine blade or vane with an impingement insert is described. Input to the program includes a description of the blade geometry, coolant supply conditions, outside thermal boundary conditions and wheel speed. Coolant-side heat transfer coefficients are calculated internally in the program, with the user specifying the mode of heat transfer at each internal flow station. Program output includes the temperature at each node, the coolant pressures and flow rates, and the inside heat transfer coefficients. A sample problem is discussed.

Gaugler, R. E.↗

Thermal-structural mission analyses of air-cooled gas turbine blades

Cyclic temperature and stress-strain states in cooled turbine blades were calculated for a simulated mission of an advanced technology aircraft engine. TACT1 (three dimensional heat transfer) and MARC (nonlinear structural analysis) computer programs were used to analyze impingement cooled airfoils, with and without leading-edge film cooling. Creep was the predominant damage mode, particularly around film cooling holes. Radially angled holes exhibited less creep than holes normal to surface. Beam-type analyses of all-impingement cooled airfoils gave fair agreement with MARC results for initial creep.

Kaufman, A.↗

Cyclic structural analyses of air-cooled gas turbine blades and vanes

The creep-fatigue behavior of a fully impingement-cooled blade for four cyclic cases was analyzed by using the Elas 55, finite-element, nonlinear structural computer program. Expected cyclic lives were calculated by using the method of Strainrange Partitioning for reversed inelastic strains and time fractions for ratcheted tensile creep strains. Strainrange Partitioning was also applied to previous results from a one-dimensional cyclic analysis of a film-impingement-cooled vane. The analyses indicated that Strainrange Partitioning is more applicable to a constrained airfoil such as the film-impingement-cooled vane than to the relatively unconstrained fully impingement-cooled airfoil.

Kaufman, A.↗

Cyclic structural analysis of air-cooled gas turbine blades and vanes

The creep fatigue behavior of a fully impingement cooled blade for four cyclic cases was analyzed by using the Elas 55, finite element, nonlinear structural computer program. Expected cyclic lives were calculated by using the method of strainrange partitioning for reversed inelastic strains and time fractions for ratcheted tensile creep strains. Strainrange partitioning was also applied to previous results from a one dimensional cyclic analysis of a film impingement cooled vane. The analyses indicated that strainrange partitioning is more applicable to a constrained airfoil such as the film impingement cooled vane than to the relatively unconstrained fully impingement cooled airfoil.

Kaufman, A.↗

High-response on-line gas analysis system for hydrogen-reaction combustion products

The results of testing an on-line quadrupole gas analyzer system are reported. Gas samples were drawn from the exhaust of a hydrogen-oxygen-nitrogen rocket which simulated the flow composition and dynamics at the combustor exit of a supersonic combustion ramjet engine. System response time of less than 50 milliseconds was demonstrated, with analytical accuracy estimated to be + or - 5 percent. For more complex chemical systems with interfering atom patterns, analysis would be more difficult. A cooled-gas pyrometer probe was evaluated as a total temperature indicator and as the primary mass flow measuring element for the total sample flow rate.

Metzler, A. J.↗

Optical measurement of static temperature and hydroxyl radical profiles in a hydrogen-fueled supersonic combustor

Profiles of static temperature and hydroxyl radical concentration were measured in a two-dimensional supersonic combustor test section 22.8 cm downstream of hydrogen injection. A high-pressure gas generator supplied vitiated air to the test section at Mach 2.44, atmospheric pressure, and a total temperature of about 2240 K. Room-temperature hydrogen was injected through a 0.40-cm step slot at Mach 1 and matched pressure. The measurements utilized a noninterfering spectral line absorption technique in which narrow ultraviolet emission lines of the hydroxyl electronic transition are absorbed by the broader absorption lines in the combustion gas. Comparison of the measured temperature profiles with theoretical calculations showed good agreement.

Gaugler, R. E.↗

Diffusive ignition and combustion in a wall jet

Hydrogen is injected from a downstream facing step in a wall into a high-temperature stream. Temperature and hydroxyl radical concentration are measured downstream of the injection plane by means of ultraviolet absorption spectroscopy. The experimental results are compared with theory which is based on a finite-difference solution of boundary-layer equations. Finite-rate kinetics equations are included in the analysis. The analytic predictions are also compared with previously obtained experimental results which are based on probe measurements. Comparison is made between calculated and observed ignition distances.

Kurkov, A. P.↗

Diffusive ignition and combustion in a wall jet

Hydrogen is injected from a downstream facing step in a wall into a high-temperature stream. Temperature and hydroxyl radical concentration are measured downstream of the injection plane by means of ultraviolet absorption spectroscopy. The experimental results are compared with theory which is based on a finite-difference solution of boundary-layer equations. Finite-rate kinetics equations are included in the analysis. The analytic predictions are also compared with previously obtained experimental results which are based on probe measurements. Comparison is made between calculated and observed ignition distances.

Kurkov, A. P.↗