Search NASASearch

Engineering topics

Gause, R. L.

Publications and source records attributed to Gause, R. L..

At least 19 records

Tribology Experiment in Zero Gravity

A tribology experiment in zero gravity was performed during the orbital flight of Spacelab 1 to study the motion of liquid lubricants over solid surfaces. The absence of a significant gravitational force facilitates observation of such motions as controlled by interfacial and capillary forces. Two experimental configurations were used. One deals with the liquid on one solid surface, and the other with the liquid between a pair of closed spaced surfaces. Time sequence photographs of fluid motion on a solid surface yielded spreading rate data of several fluid-surface combinations. In general, a slow spreading process as governed by the tertiary junction can be distinguished from a more rapid process which is driven by surface tension controlled internal fluid pressure. Photographs were also taken through the transparent bushings of several experimental journal bearings. Morphology of incomplete fluid films and its fluctuation with time suggest the presence or absence of unsteady phenomena of the bearing-rotor system in various arrangements.

Pan, C. H. T.

Tribology experiment in zero gravity

A tribology experiment in zero gravity was performed during the orbital flight of Spacelab 1 to study the motion of liquid lubricants over solid surfaces. The absence of a significant gravitational force facilitates studies of the motion of liquid lubricants over solid surfaces as controlled by interfacial and capillary forces. Observations were made of phenomena associated with the liquid on one solid surface and also with the liquid between a pair of closely spaced surfaces. Typical photographic records obtained on Spacelab 1 are described.

Pan, C. H. T.

Protection of solar collector materials from UV

Certain plastic films, such as KAPTON, are known to be stable with excellent long-term aging characteristics under intense uv radiation. Our recent measurements of the optical transmission spectra of KAPTON films show an absorption edge in the blue and are interpreted in terms of an electronic excitation mechanism. The application of this type of film as covering for solar collectors is discussed in regard to the protection this strong uv absorption offers to the materials underneath.

Castle, J. G., Jr.

Parameters affecting electrostatic cooling

A high voltage electrostatic field is discussed which enhances the rate of normal convective cooling. This cooling rate is a function of starting temperature and voltage applied, and an inverse function of atmospheric pressure or the heat capacity of the surrounding media. It appears that the cooling rate is also a function of current flow; however, additional work is needed to separate other variables from the effect of current flow. The maximum increase in heat loss over the normal convective cooling was approximately 0.167 C/sec (0.3 F/sec) at 316 C (600 F) and 20,000 V. From the data taken it is assumed that the addeded rate of cooling would be increased with higher temperatures and higher voltages. It appears that a high voltage field disrupts the molecular layer of air surrounding a hot body and increases the rate of convective cooling.

Demorest, K. E.

Ergometer calibrator

An apparatus is presented for accurately calibrating ergometers so that the work rate produced by the particular ergometer being calibrated is accurate. The apparatus includes a dc motor which is coupled directly to the ergometer for rotating it at various speeds. Positioned on the shaft between the dc motor and the ergometer is a torque sensor and tachometer, which feed signals to a power computer for subsequent recording. A speed controller is utilized with the dc motor.

Gause, R. L.

Development innovations for Skylab student experiments

The Skylab Student Science Program was an effort on the part of NASA and the National Science Teachers Association (NSTA) to provide the youth of America an opportunity to directly participate in space research. Students across the nation submitted proposed experiments which were scientifically evaluated by the NSTA. From the more than three thousand experiments submitted, twenty-five of the most innovative and novel experiments were selected for flight. Many of these required the development of flight hardware in order to perform the experiments aboard Skylab. The requirements placed on the hardware in terms of cost, development time, weight, volume, and crew training represented a unique challenge to the NASA engineers and scientists involved in the design, development, fabrication and testing of this hardware. To meet these stringent requirements required innovative changes in the classic Skylab approach to experiment development.

Gause, R. L.

Conductive elastomeric extensometer

An extensometer was used for measuring surface area changes of the human body caused by expansion and contraction of the body. A relatively thin and wide strain responsive conductive elastomeric band was adapted for application to a part of the body, such as around a limb or the trunk of the body. The elastomeric band is incorporated as a resistor in a balanced bridge circuit. Expansion or contraction of the portion of the body on which the elastomeric band is applied causes a change in the resistance of the band and a resultant imbalance of the bridge circuit. The output of the amplifier in volts is suitable for proving the desired reading through a recorder, oscilloscope or voltmeter.

Gause, R. L.

Manual actuator

An actuator for an exercising machine employable by a crewman aboard a manned spacecraft is presented. The actuator is characterized by a force delivery arm projected from a rotary imput shaft of an exercising machine and having a force input handle extended orthogonally from its distal end. The handle includes a hand-grip configured to be received within the palm of the crewman's hand and a grid pivotally supported for angular displacement between a first position, wherein the grid is disposed in an overlying juxtaposition with the hand-grip, and a second position, angularly displaced from the first position, for affording access to the hand-grip, and a latching mechanism fixed to the sole of a shoe worn by the crewman for latching the shoe to the grid when the grid is in the first position.

Gause, R. L.

Tilting table for ergometer and for other biomedical devices

The apparatus is for testing the human body in a variety of positions, ranging from the vertical to the supine, while exercising on an ergometer; and can also be used for angular positioning of other biomedical devices. It includes a floor plate and a hinged plate upon which to fix the ergometer, a back rest and a head rest attached at right angles to said hinged plate and behind the seat of the ergometer, dual hydraulic cylinders for raising and lowering the hinged plate through 90 deg by means of a self contained hydraulic system, with valve means for control and positive stops on the apparatus to prevent over travel. Tests can be made with the subject positioned on the seat of the ergometer, through the various angles, with a substantially normal body attitude relative to the seat and ergometer.

Gause, R. L.

Restraint system for ergometer

A restraint system for securing a person to an ergometer while exercising under zero gravity conditions or while operating the ergometer in earth environment in a position other than the upright position. A padded, form-fitting body belt fits around the operator's waist and suspenders are attached to the body belt. The body belt is secured to the ergometer forwardly and rearwardly of the ergometer seat by adjustable belts joined to the body belt and releasably hooked to the ergometer frame.

Gause, R. L.

Ergometer

An ergometer is described that has a pedal driven direct current motor as a load and includes a frame for supporting the body of a person in either a sitting or a prone position. The pedals may be operated by either the feet or the hands. The electrical circuitry of the ergometer includes means for limiting the load applied to the pedals as a function of work being performed, heart rate, and increases in heart rate.

Gause, R. L.

Tilt table for ergometers and other biomedical devices

Table adjusts to any position between horizontal and vertical. Apparatus includes - floor plate, plate hinged to floor plate, for carrying ergometer, hydraulic cylinder and piston on plate sides, linking them, hydraulic system, positive stops, padded backrest and headrest, one hand controls, and constraint system.

Gause, R. L.

Multimode ergometer system

System overcomes previous ergometer design and calibration problems including inaccurate measurements, large weight, size, and input power requirements, poor heat dissipation, high flammability, and inaccurate calibration. Device consists of lightweight, accurately controlled ergometer, restraint system, and calibration system.

Bynum, B. G.

Hydraulically operated tilt table

Table raises, lowers, or tilts test subject from vertical through an angle of 105 deg to a head-down position of 15 deg. Table is designed for medical center or laboratory use. Additional features are described.

Gause, R. L.