Engineering topics
Gauthier, J.
Publications and source records attributed to Gauthier, J..
Apparent temperatures of neutron-poor and neutron-rich compound nuclei
The possibility of the dependence of the nuclear caloric curve on neutron excess sets a limit on the accuracy of our knowledge of the nuclear equation of state, and thus impacts predictive capabilities of nuclear reaction and nuclear astrophysics models. To date, theoretical models have not reached consensus on the magnitude or sign on the asymmetry dependence. To provide constraints, we have measured evaporated particles and heavy residues for complete and incomplete fusion-evaporation reactions in inverse kinematics. The temperatures extracted from the observed light charged particles tend to favor higher temperatures for the neutron-rich fused systems, though they are near the limits of the systematic uncertainty. The present measurement may be used as an upper limit to constrain the asymmetry dependence of the nuclear caloric curve.
High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST
The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.
Investigating the time dependence of neutron-proton equilibration using molecular dynamics simulations
Neutron-proton equilibration has previously been studied experimentally in dynamically deformed nuclei in heavy ion collisions [Phys. Rev. Lett. 118, 062501 (2017); Phys. Rev. C 95, 044604 (2017)] using the NIMROD detector array at the Cyclotron Institute at Texas A&M University. Results indicated the composition of the two heaviest fragments originating from the excited projectile-like fragment evolved exponential with respect to their orientation angle to be more similar. Constrained Molecular Dynamics and Antisymmetrized Molecular Dynamics simulations were performed for different formulations of the density dependence of the asymmetry energy term of the nuclear equation of state. The simulations are compared to experimental results, which indicate a better agreement with a softer interaction in the nuclear equation of state.
Investigation of sCVD diamond detectors for low energy heavy-ion reactions
Here the performance characteristics of single-crystalline diamond detectors at varying rates of heavy-ions below 50 MeV/u have been investigated. When tested with a 228 Th source, the energy resolution of these detectors is better than 1.0% FWHM for 8.8 MeV α-particles. With a slight reduction in the energy resolution, simultaneous timing resolution of 314 ps has been achieved. Isotopic resolution has been achieved up to magnesium using a diamond telescope at low rates with a 20 MeV/u 20 Ne + 12 C reaction. At moderate rates of direct 7.5 MeV/u 78 Kr, polarization effects are observed, though this effect can be diminished by increasing the applied voltage on the detector up to a limit. After an accumulated dose of 6.9 × 10 8 direct 78 Kr particles transmitting through the detector, a degradation in the energy resolution of the 8.8 MeV peak from 1.6% to 5.3% is observed, indicating that permanent damage has been done to the detector.
Correlation between time and angular alignment in molecular dynamics simulations of heavy ion collisions
Neutron-proton equilibration is a process which has been used to study the density dependence of the symmetry energy term in the nuclear equation-of-state. Here, this study utilizes constrained molecular dynamics (CoMD) simulations of 70 Zn + 70 Zn with collision energies of 35 and 45 MeV/nucleon. An algorithm is used which searches through CoMD events and identifies the PLF* after it separates from the target and determines its lifetime, Δt. It also determines the fragments that the PLF* breaks apart into and determines their angular alignment. This technique gives an opportunity to explore how the average alignment of dynamically produced fragments, $\langle$α $\rangle$ dyn , evolves with PLF* lifetime. An approximately linear relationship was determined with d$\langle$α $\rangle$ dyn /dΔt = 0.98 ± 0.08 rad / zs and 1.06 ± 0.09 rad / zs for the 35 and 45 MeV / nucleon, respectively, indicating a correlation with magnitude consistent with classically determined values which were used for prior experimental studies.
Isotopic equilibrium constants for very low-density and low-temperature nuclear matter
Yields of equatorially emitted light isotopes, 1 ≤ Z ≤ 14, observed in ternary fission in the reaction 241 Pu(n th, f) are employed to determine apparent chemical equilibrium constants for low-temperature and low-density nuclear matter. The degree of equilibration and role of medium modifications are probed through a comparison of experimentally derived reaction quotients with equilibrium constants calculated using a relativistic mean-field model employing a universal medium modification correction for the attractive σ meson coupling. The results of these comparisons indicate that equilibrium is achieved for the lighter ternary fission isotopes. For the heavier isotopes experimental reaction quotients are well below calculated equilibrium constants. This is attributed to a dynamical limitation reflecting insufficient time for full equilibrium to develop. The role of medium effects leading to yield reductions is discussed as is the apparent enhancement of yields for 8 He and other very neutron rich exotic nuclei.
A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector
The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.