Search NASA⌕ Search

Engineering topics

Ge, Ning

Publications and source records attributed to Ge, Ning.

Real-Time Sensing of Single-Ligand Delivery with Nanoaperture-Integrated Microfluidic Devices

The measurement of biological events on the surface of live cells at the single-molecule level is complicated by several factors including high protein densities that are incompatible with single-molecule imaging, cellular autofluorescence, and protein mobility on the cell surface. Here, we fabricated a device composed of an array of nanoscale apertures coupled with a microfluidic delivery system to quantify single-ligand interactions with proteins on the cell surface. We cultured live cells directly on the device and isolated individual epidermal growth factor receptors (EGFRs) in the apertures while delivering fluorescently labeled epidermal growth factor. We observed single ligands binding to EGFRs, allowing us to quantify the ligand turnover in real time. These results demonstrate that this nanoaperture-coupled microfluidic device allows for the spatial isolation of individual membrane proteins while maintaining them in their cellular environment, providing the capability to monitor single-ligand binding events while maintaining receptors in their physiological environment. Lastly, these methods should be applicable to a wide range of membrane proteins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anatomy of Ag/Hafnia-Based Selectors with 10 10 Nonlinearity

We developed a novel Ag/oxide-based threshold switching device with attractive features including ≈10 10 nonlinearity. Furthermore, in a high-resolution transmission electron microscopic analysis of the nanoscale crosspoint device it is suggested that elongation of an Ag nanoparticle under voltage bias followed by spontaneous reformation of a more spherical shape after power off, is responsible for the observed threshold switching.

36 MATERIALS SCIENCE↗

Memristors with diffusive dynamics as synaptic emulators for neuromorphic computing

The accumulation and extrusion of Ca 2+ in the pre- and postsynaptic compartments play a critical role in initiating plastic changes in biological synapses. In order to emulate this fundamental process in electronic devices, we developed diffusive Ag-in-oxide memristors with a temporal response during and after stimulation similar to that of the synaptic Ca 2+ dynamics. In situ high-resolution transmission electron microscopy and nanoparticle dynamics simulations both demonstrate that Ag atoms disperse under electrical bias and regroup spontaneously under zero bias because of interfacial energy minimization, closely resembling synaptic influx and extrusion of Ca 2+ , respectively. Furthermore, the diffusive memristor and its dynamics enable a direct emulation of both short- and long-term plasticity of biological synapses, representing an advance in hardware implementation of neuromorphic functionalities.

36 MATERIALS SCIENCE↗