Maximization of performance in multi-tube latent heat storage – Optimization of fins topology, effect of materials selection and flow arrangements

This paper addresses the need of multi-tube latent heat thermal storage (LHTES) systems with enhanced heat transfer performance. Uniquely, this work draws from topology optimization method for thermal energy storage to search for the optimal configuration of fins in multi-tube LHTES systems with different phase change materials (PCMs), flow arrangements and design constraints. The design freedom of topology optimization allows the discovery of innovative LHTES designs and elucidate the link between design and physical processes occurring during charging/discharging. Three key results of this study are: i) the optimized fin design is tightly connected to the type of storage duty cycle, which demonstrates the necessity to account for realistic operating conditions in the optimization process. ii) The fin material should be chosen in parallel with the layout of the fins and not sequentially as commonly done; this indicates that the optimization of LHTES systems is a co-design challenge. iii) Topology optimized multi-tube LHTES units surpass in performance fins optimized for a single-tube configuration in a multi-tube unit. Finally, this work demonstrates for the first time the manufacturability of topology-optimized LHTES units by using 3D printing.

25 ENERGY STORAGE↗

Measurement strategy for rectangular electrical capacitance tomography sensor

To investigate the influence of the measurement strategy for the rectangular electrical capacitance tomography (ECT) sensor, a Finite Element Method (FEM) is utilized to create the model for simulation. The simulation was carried out using COMSOL Multiphysics(trade mark, serif) and Matlab(trade mark, serif). The length-width ratio of the rectangular sensing area is 5. Twelve electrodes are evenly arranged surrounding the pipe. The covering ratio of the electrodes is 90%. The capacitances between different electrode pairs are calculated for a bar distribution. The air of the relative permittivity 1.0 and the material of the permittivity 3.0 are used for the calibration. The relative permittivity of the second phase is 3.0. The noise free and noise data are used for the image reconstruction using the Linear Back Projection (LBP). The measurement strategies with 1-, 2- and 4- electrode excitation are compared using the correlation coefficient. Preliminary results show that the measurement strategy with 2-electrode excitation outperforms other measurement strategies with 1- or 4-electrode excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗