Search NASA⌕ Search

Engineering topics

Gehring, Amanda

Publications and source records attributed to Gehring, Amanda.

An approach to characterizing spatial aspects of image system blur

Quantitative X-ray radiographic imaging systems that utilize a charged couple device (CCD) camera connected to a thick, monolithic scintillator can exhibit blur that varies spatially across the field of view, especially for thick scintillators used in pulse-power radiography of dynamically compressed objects. Here, a three-point approach to estimating and accounting for this effect is demonstrated by (a) using a local estimation technique to measure the effect of blurring a calibration object at key locations across the field of view, (b) combining each of the local estimates into a spatially varying blurring function via partitions of unity interpolation, and (c) resolving the effects of that blur on the image by solving an ill-posed inverse problem using a spatially varying regularization term. The technique is demonstrated on synthetic examples and actual radiographs collected at the Naval Research Laboratory’s (NRL)Mercury pulsed power facility.

97 MATHEMATICS AND COMPUTING↗

Reduction of Radiographic Spot Size with Dual Diameter Sub-mm Rods

Among the most dominant factors in x-ray radiographic image resolution is the radiographic spot size, which is primarily a function of the physical extent of the x-ray source, so the most marked improvements in image resolution come from modifying the pulse power driver’s diode configuration to reduce that extent. The smaller the size of the x-ray spot, the higher the image resolution potential. The U.S. Naval Research Laboratory’s Mercury pulsed power accelerator has been configured with a rod-pinch diode, and recent measurements were conducted to demonstrate the impact of anode rod geometry on x-ray spot size. The “standard” anode rod is a 0.75 mm diameter cylinder that is tapered down to 0.25 mm over a length of 5 mm, and, in this study, it was replaced by rods with a sharp step between their two diameters, rather than a taper. The effect on spot size was assessed by analyzing the edge and line spread functions calculated from high-mag rolled edge and pinhole camera images. For certain diameter pairs, a reduction in radiographic spot size is observed. In addition, the dual-diameter rods have provided unique insight into the electron-anode coupling dynamics that are at play in all diodes of this type.

X-ray radiography, spot size↗