Search NASA⌕ Search

Engineering topics

Geiger, B.

Publications and source records attributed to Geiger, B..

At least 19 records

Visible core spectroscopy at Wendelstein 7-X

This paper presents an overview of recent hardware extensions and data analysis developments to the Wendelstein 7-X visible core spectroscopy systems. These include upgrades to prepare the in-vessel components for long-pulse operation, nine additional spectrometers, a new line of sight array for passive spectroscopy, and a coherence imaging charge exchange spectroscopy diagnostic. Progress in data analysis includes ion temperatures and densities from multiple impurity species, a statistical comparison with x-ray crystal spectrometer measurements, neutral density measurements from thermal passive Balmer-alpha emission, and a Bayesian analysis of active hydrogen emission, which is able to infer electron density and main ion temperature profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Compelling Need for a Mid-Scale Stellarator Facility

In the pursuit of the goal of commercial fusion as an abundant and safe source of energy, the stellarator is a leading concept with compelling attractiveness and demonstrated performance. In this white paper we, as a community of US researchers from Universities, National Laboratories, and Private Industry, involved in studying the stellarator concept, lay out the programmatic and technical motivation for a new mid-size stellarator research facility in the US. This contribution is complementary to several other whitepapers authored by members of our community which address different mid-scale stellarator aspects. A community based technical facility proposal has been prepared by F. Parra, et al: Flexible Stellarator Physics Facility. Two private stellarator companies have submitted proposals supporting the development of a mid-scale stellarator: Thea Energy (C.P.S. Swanson, et al.), Type One Energy (W. Guttenfelder, et al.).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Compelling Need for a Mid-Scale Stellarator Facility

In the pursuit of the goal of commercial fusion as an abundant and safe source of energy, the stellarator is a leading concept with compelling attractiveness and demonstrated performance. A new mid-size stellarator is needed to retire risks and innovate towards a high performance, economically attractive, stellarator Fusion Pilot Plant. In this presentation we, as a community of US researchers from Universities, National Laboratories, and Private Industry, involved in studying the stellarator concept, lay out the programmatic and technical motivation for a new and modern mid-size stellarator research facility. A new mid-scale stellarator is needed to realize the potential predicted by a solid body of theory and simulation along with advances in computational tools for optimization and non-linear turbulence modeling. Notably, it is possible to combine the advantages of the stellarator (steady state, no current drive, no disruptions) with the good confinement regularly achieved in tokamaks. The top priorities for experimental work, and the motivation for a mid-scale stellarator experiment are: turbulence control, non-resonant divertor, MHD stability at large beta, confinement of fast particles, and coil simplification. A new mid-size quasi-symmetric stellarator, built as a user facility, would complement existing research at Wendelstein 7-X and LHD and strongly augment private industry. It would provide a program of innovative research, concept validation, theoretical advancement, and workforce development. Growing support and interest for stellarators by the fusion community and private industry affirms this rationale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design study of an edge current density diagnostic using new high-performance single-channel beam emission spectrometers at DIII-D

A novel Motional Stark Effect spectroscopy system has been designed for application at the DIII-D tokamak. The system is optimized for studies of the poloidal and toroidal magnetic field in the plasma pedestal region with frame rates of up to 10 kHz. Further, light from an existing high-photon-throughput collection lens is analyzed using four single-channel f/2.8 Czerny–Turner spectrometers that use custom-made lens systems instead of mirrors. Each spectrometer has two separate outgoing legs and is operated in a positive grating order, which allows for simultaneous observations of D-alpha and D-beta spectra. Forward modeling using the code FIDASIM shows a radial resolution of the system close to 0.6 cm and sufficiently good spectral resolution when masking the high throughput light collection lens in the horizontal direction to avoid overly strong Doppler broadening of beam emission lines. Moreover, a detailed sensitivity study considering realistic levels of readout and photon noise shows that the poloidal and toroidal magnetic field strengths can be inferred with an uncertainty of less than 1%, which will allow the inference of changes of the plasma current during transient events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual design and performance predictions for 2D beam emission spectroscopy turbulence measurements at Wendelstein 7-X

A conceptual design for a 2D beam emission spectroscopy diagnostic system to measure ion gyro-scale plasma turbulence at Wendeslstein 7-X is described. The conceptual design identifies field-aligned viewing geometries and ports for cross-field turbulence measurements in the neutral beam volume. A 2D sightline grid covers the outer plasma region, and the grid configuration provides sufficient k-space coverage in radial and poloidal directions for ion temperature gradient and trapped-electron mode turbulence measurements. Emission intensity estimates, optical transmission losses, and detector noise levels indicate that the measurements will be sensitive to plasma density fluctuations as small as δn/n ≈ 0.5% with a bandwidth of 1 MHz. Implementation challenges include a small beam emission Doppler shift due to nearly radial heating beams and reduced optical throughput due to collection aperture limitations.

47 OTHER INSTRUMENTATION↗

Orbit tomography of energetic particle distribution functions

Both fast ions and runaway electrons are described by distribution functions, the understanding of which are of critical importance for the success of future fusion devices such as ITER. Typically, energetic particle diagnostics are only sensitive to a limited subsection of the energetic particle phase-space which is often insufficient for model validation. However, previous publications show that multiple measurements of a single spatially localized volume can be used to reconstruct a distribution function of the energetic particle velocity-space by using the diagnostics' velocity-space weight functions, i.e. velocity-space Tomography. In this work we use the recently formulated orbit weight functions to remove the restriction of spatially localized measurements and present orbit tomography, which is used to reconstruct the 3D phase-space distribution of all energetic particle orbits in the plasma. Through a transformation of the orbit distribution, the full energetic particle distribution function can be determined in the standard {energy, pitch, r, z}-space. We benchmark the technique by reconstructing the fast-ion distribution function of an MHD-quiescent DIII-D discharge using synthetic and experimental FIDA measurements. We also use the method to study the redistribution of fast ions during a sawtooth crash at ASDEX upgrade using FIDA measurements. Lastly, a comparison between the orbit tomography and velocity-space tomography is shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Confinement in electron heated plasmas in Wendelstein 7-X and ASDEX Upgrade; the necessity to control turbulent transport

In electron (cyclotron) heated plasmas, in both ASDEX Upgrade (L-mode) and Wendelstein 7-X, clamping of the ion temperature occurs at $T_\mathrm{i}$ ~ 1.5 keV independent of magnetic configuration. The ions in such plasmas are heated through the energy exchange power as ${n}_{\mathrm{e}}^{2}({T}_{\mathrm{e}}-{T}_{\mathrm{i}})/{T}_{\mathrm{e}}^{3/2}$, which offers a broad ion heating profile, similar to that offered by alpha heating in future thermonuclear fusion reactors. However, the predominant electron heating may put an additional constraint on the ion heat transport, as the ratio $T_\mathrm{e}T_\mathrm{i}$ > 1 can exacerbates ITG/TEM core turbulence. Therefore, in practical terms the strongly 'stiff' core transport translates into Ti-clamping in electron heated plasmas. Due to this clamping, electron heated L-mode scenarios, with standard gas fueling, in either tokamaks or stellarators may struggle to reach high normalized ion temperature gradients required in a compact fusion reactor. The comparison shows that core heat transport in neoclassically optimized stellarators is driven by the same mechanisms as in tokamaks. The absence of a strong H-mode temperature edge pedestal in stellarators, sofar (which, like in tokamaks, could lift the clamped temperature-gradients in the core), puts a strong requirement on reliable and sustainable core turbulence suppression techniques in stellarators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impurity transport studies at the HSX stellarator using active and passive CVI spectroscopy

The transport of carbon impurities has been studied in the helically symmetric stellarator experiment (HSX) using active and passive charge exchange recombination spectroscopy (CHERS). For the analysis of the CHERS signals, the STRAHL impurity transport code has been re-written in the python programming language and optimized for the application in stellarators. In addition, neutral hydrogen densities both along the NBI line of sight as well as for the background plasma have been calculated using the FIDASIM code. By using the basinhopping algorithm to minimize the difference between experimental and predicted active and passive signals, significant levels of impurity diffusion are observed. In this work, comparisons with neoclassical calculations from DKES/PENTA show that the inferred levels exceed the neoclassical transport by about a factor of four in the core and more than 100 times towards the plasma edge, thus indicating a high level of anomalous transport. This observation is in agreement with experimental heat diffusivites determined from a power balance analysis which exhibits strong anomalous transport as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser blow-off with photodiode detection system at the helically symmetric experiment

Abstract A laser blow-off (LBO) system has been installed in the HSX stellarator to investigate impurity transport. A Nd:YAG laser is used to ablate a target area on a glass slide that has been coated with a thin film of aluminum and rapidly deposits a small, controlled quantity of aluminum atoms into HSX plasma. To study the radial propagation and confinement of the injected aluminum impurities, time-resolved emission measurements are made using a 20 channel AXUV photodiode detection system. The LBO system has achieved its design purpose, most notably the ability to make controlled impurity injection without significant perturbation to the background plasma. A detailed description of the setup as well as initial results of operation are presented.

Instruments & Instrumentation↗

Overview of the TCV tokamak program: Scientific progress and facility upgrades

The TCV tokamak is augmenting its unique historical capabilities (strong shaping, strong electron heating) with ion heating, additional electron heating compatible with high densities, and variable divertor geometry, in a multifaceted upgrade program designed to broaden its operational range without sacrificing its fundamental flexibility. The TCV program is rooted in a three-pronged approach aimed at ITER support, explorations towards DEMO, and fundamental research. A 1 MW, tangential neutral beam injector (NBI) was recently installed and promptly extended the TCV parameter range, with record ion temperatures and toroidal rotation velocities and measurable neutral-beam current drive. ITER-relevant scenario development has received particular attention, with strategies aimed at maximizing performance through optimized discharge trajectories to avoid MHD instabilities, such as peeling-ballooning and neoclassical tearing modes. Experiments on exhaust physics have focused particularly on detachment, a necessary step to a DEMO reactor, in a comprehensive set of conventional and advanced divertor concepts. The specific theoretical prediction of an enhanced radiation region between the two X-points in the low-field-side snowflake-minus configuration was experimentally confirmed. Fundamental investigations of the power decay length in the scrape-off layer (SOL) are progressing rapidly, again in widely varying configurations and in both D and He plasmas; in particular, the double decay length in L-mode limited plasmas was found to be replaced by a single length at high SOL resistivity. Experiments on disruption mitigation by massive gas injection and electron-cyclotron resonance heating (ECRH) have begun in earnest, in parallel with studies of runaway electron generation and control, in both stable and disruptive conditions; a quiescent runaway beam carrying the entire electrical current appears to develop in some cases. Developments in plasma control have benefited from progress in individual controller design and have evolved steadily towards controller integration, mostly within an environment supervised by a tokamak profile control simulator. TCV has demonstrated effective wall conditioning with ECRH in He in support of the preparations for JT-60SA operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion temperature and rotation fluctuation measurements with ultra-fast charge exchange recombination spectroscopy (UF-CHERS) in the DIII-D tokamak

An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103–104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.

Truong, D. D. (ORCID:0000000285732539)↗

Preparation, analysis, and application of coated glass targets for the Wendelstein 7-X laser blow-off system

Coated glass targets are a key component of the Wendelstein 7-X laser blow-off system that is used for impurity transport studies. The preparation and analysis of these glass targets as well as their performance is examined in this paper. The glass targets have a high laser damage threshold and are coated via physical vapor deposition with μm thick films. In addition, nm-thin layers of Ti are used as an interface layer for improved ablation efficiency and reduced coating stress. Hence, the metallic or ceramic coating has a lateral homogeneity within 2% and contaminants less than 5%, being optimal for laser ablation processing. With this method, a short (few ms) and well defined pulse of impurities with about 1017 particles can be injected close to the last closed flux surface of Wendelstein 7-X. In particular, a significant amount of atoms with a velocity of about 1 km/s enters the plasma within 1 ms. The atoms are followed by a negligible concentration of slower clusters and macro-particles. This qualifies the use of the targets and applied laser settings for impurity transport studies with the laser blow-off system in Wendelstein 7-X.

47 OTHER INSTRUMENTATION↗

Charge-state independent anomalous transport for a wide range of different impurity species observed at Wendelstein 7-X

Here, the plasma volume averaged impurity confinement of selected charge states and impurity species has been characterized for the Stellarator Wendelstein 7-X (W7-X), covering a wide range of atomic charges (Z = 12–44) and atomic masses (M = 28–184). A comparison of the experimental findings to theoretical neoclassical and turbulent transport expectations suggests, aside from/in addition to the neoclassical transport, an additional significant anomalous transport mechanism, which is not inconsistent with the predictions of a turbulence dominated impurity transport and is in agreement with the experimental results from recent transport studies based on the direct measurements of impurity diffusion profiles, performed at W7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge exchange recombination spectroscopy at Wendelstein 7-X

The Charge Exchange Recombination Spectroscopy (CXRS) diagnostic has become a routine diagnostic on almost all major high temperature fusion experimental devices. For the optimized stellarator Wendelstein 7-X (W7-X), a highly flexible and extensive CXRS diagnostic has been built to provide high-resolution local measurements of several important plasma parameters using the recently commissioned neutral beam heating. This paper outlines the design specifics of the W7-X CXRS system and gives examples of the initial results obtained, to include typical ion temperature profiles for several common heating scenarios, toroidal flow and radial electric field derived from velocity measurements, beam attenuation via beam emission spectra, and normalized impurity density profiles under some typical plasma conditions.

47 OTHER INSTRUMENTATION↗

Overview of first Wendelstein 7-X high-performance operation

The optimized superconducting stellarator device Wendelstein 7-X (with major radius R = 5.5 m, minor radius $a$ = 0.5 m, and 30 m 3 plasma volume) restarted operation after the assembly of a graphite heat shield and 10 inertially cooled island divertor modules. This paper reports on the results from the first high-performance plasma operation. Glow discharge conditioning and ECRH conditioning discharges in helium turned out to be important for density and edge radiation control. Plasma densities of 1–4.5 × 10 19 m –3 with central electron temperatures 5–10 keV were routinely achieved with hydrogen gas fueling, frequently terminated by a radiative collapse. In a first stage, plasma densities up to 1.4 × 10 20 m –3 were reached with hydrogen pellet injection and helium gas fueling. Here, the ions are indirectly heated, and at a central density of 8 · 10 19 m –3 a temperature of 3.4 keV with $T_e/T_i$ = 1 was transiently accomplished, which corresponds to $nT_i(0)τ_E =$ 6.4 × 10 19 keV s m –3 with a peak diamagnetic energy of 1.1 MJ and volume-averaged normalized plasma pressure $\langleβ\rangle$ = 1.2%. The routine access to high plasma densities was opened with boronization of the first wall. After boronization, the oxygen impurity content was reduced by a factor of 10, the carbon impurity content by a factor of 5. The reduced (edge) plasma radiation level gives routinely access to higher densities without radiation collapse, e.g. well above 1 × 10 20 m –2 line integrated density and $T_e = T_i =$ 2 keV central temperatures at moderate ECRH power. Both X2 and O2 mode ECRH schemes were successfully applied. Core turbulence was measured with a phase contrast imaging diagnostic and suppression of turbulence during pellet injection was observed.

impurities↗

Impurity transport studies at Wendelstein 7-X by means of x-ray imaging spectrometer measurements

This study reports on the effect of on- and off-axis heating power deposition on the impurity confinement in purely electron cyclotron resonance heated He plasmas on the stellarator Wendelstein 7-X. Therefore, impurity transport times τ I have been determined after Fe impurity injections by laser ablations and monitoring the temporal impurity emissivities by the x-ray imaging spectrometer HR-XIS. A significant increase of τ I has been observed when changing the power deposition from on- to off-axis heating with energy confinement times τ E being mainly unaffected. In addition, the scaling of impurity transport properties with respect to a variation of heating power P ECRH and electron density n e has been investigated by keeping the heating power deposition on-axis. The observed τ I scaling compares well to known τ I scaling laws observed in other machines. A comparison of τ I and τ E yields an averaged ratio of τ E /τ I = 1.3 and transport times in the range of τ I = 40–130 ms and τ E = 40–190 ms. Comparing those absolute values to neoclassical predictions supports the recently observed nature of anomalous transport in Wendelstein 7-X, given within the up to now investigated operational parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma impurities observed by a pulse height analysis diagnostic during the divertor campaign of the Wendelstein 7-X stellarator

The paper reports on the optimization process of the soft X-ray pulse height analyzer installed on the Wendelstein 7-X (W7-X) stellarator. It is a 3-channel system that records X-ray spectra in the range from 0.6 to 19.6 keV. X-ray spectra, with a temporal and spatial resolution of 100 ms and 2.5 cm (depending on selected slit sizes), respectively, are line integrated along a line-of-sight that crosses near to the plasma center. In the second W7-X operation phase with a carbon test divertor unit, we report light impurities, e.g., carbon and oxygen, were observed as well as mid- to high-Z elements, e.g., sulfur, chlorine, chromium, manganese, iron, and nickel. In addition, X-ray lines from several tracer elements have been observed after the laser blow-off injection of different impurities, e.g., silicon, titanium, and iron, and during discharges with prefill or a gas puff of neon or argon. These measurements were achieved by optimizing light absorber-foil selection, which defines the detected energy range, and remotely controlled pinhole size, which defines photon flux. The identification of X-ray lines was confirmed by other spectroscopic diagnostics, e.g., by the High-Efficiency XUV Overview Spectrometer, HEXOS, and high-resolution X-ray imaging spectrometer, HR-XIS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗