Porous Anode Model for Coal Syngas Fuelled SOFC: Combined Mass and Energy Transport Normal to Cell Plane

Solid oxide fuel cells are being developed for integrated gasification combined cycle hybrid power systems. It is therefore necessary to evaluate the coupled temperature and concentration profiles for SOFC anodes exposed to coal syngas. In this work the SOFC anode was treated as a porous composite of 50/50 (volume) Ni / YSZ. Porous transport was modeled using the dusty gas model (DGM) and included two pore reactions, namely water gas shift and steam reforming of methane. The thermal transport model considered heat exchange by radiation between the interconnect and SOFC surface, convective transfer from bulk gas flow over the anode, heat generation terms due to pore reactions, and heat generation terms at the electrolyte boundary due to electrochemical reactions, ohmic heating, and concentration polarization. Composition profiles throughout the porous anode were considered for the DGM alone and were compared to the DGM including energy (DGME). The cases examined were for current densities ranging from 0.000-0.750 A/cm2 and for pressures from 1-19 atm absolute. Simulation results predict that the average cell operating temperature will increase 10 to 60°C relative to the furnace wall with inclusion of the energy equations. However, the thermal gradients within the anode are small due to the good thermal conductivity of the Ni-based anode. The effect of inclusion of energy transport on the hydrogen concentration profile is mixed depending on the independent parameter considered, with relative insensitivity to changes in the current density, but modest sensitivity to changes in operating pressure. Consideration of the thermal transport is important for determination of the interaction of coal syngas trace species with the anode, but is less critical for material stability.

01 COAL, LIGNITE, AND PEAT↗

RGA Analysis of a Solid Oxide Fuel Cell Gas Turbine Hybrid Plant

This paper presents a Relative Gain Array (RGA) analysis of a simulated SOFC/Gas Turbine plant based on a multivariate empirical formulation of a 300kW hybrid system. The HyPer test facility at the National Energy Technology Laboratory, served as the test bed for deriving frequency response data and subsequent multivariable model of a direct fired, recuperated hybrid cycle plant. Through the modulation of various airflow bypass-valves, magnitude and phase data is used to formulate Transfer Function {TF} equations that describe input/output system interaction. A frequency dependent RGA calculation of the empirical Transfer Function matrix provides a means of quantifying the degree of coupling between system inputs and outputs for the configuration studied. Various input/output interaction time scales are obtained to identify frequencies where fully developed system coupling occur. Analysis of the RGA matrix leads to a better understanding of the inherent properties the hybrid configuration, and can serve as a validating tool to existing analytical RGA calculations of similar types of hybrids.

30 DIRECT ENERGY CONVERSION↗

Control Sensitivity Study for a Hybrid Fuel Cell/Gas Turbine System

The National Energy Technology Laboratory (NETL) has developed a hardware simulator to test the operating characteristics of Solid Oxide Fuel Cell/Gas Turbine (SOFC/GT) hybrid systems. The Hybrid Performance (HyPer) simulator has been described previously, and has contributed to the understanding of SOFC/GT system operation. HyPer contains not only the requisite elements of gas turbine/compressor/generator, recuperator, combustor, and associated piping, but also several air flow control valves that are proposed as system control mechanisms. It is necessary to know how operation of these valves affects the various entities such as cathode air flow, turbine speed, and various temperatures important to the safe and efficient operation of fuel cell/gas turbine hybrid systems. To determine the interactions among key variables, a series of experiments was performed in which the effect of modulating each of the key manipulated variables was recorded. This document outlines the test methods used and presents some of the data from those tests, along with analysis and interpretation of that data in the context of control system design.

30 DIRECT ENERGY CONVERSION↗

Multivariable Robust Control of a Simulated Hybrid Solid Oxide Fuel Cell Gas Turbine Plant

This paper presents a systematic approach to the multivariable robust control of a hybrid fuel cell gas turbine plant. The hybrid configuration under investigation comprises a physical simulation of a 300kW fuel cell coupled to a 120kW auxiliary power unit single spool gas turbine. The facility provides for the testing and simulation of different fuel cell models that in turn help identify the key issues encountered in the transient operation of such systems. An empirical model of the facility consisting of a simulated fuel cell cathode volume and balance of plant components is derived via frequency response data. Through the modulation of various airflow bypass valves within the hybrid configuration, Bode plots are used to derive key input/output interactions in Transfer Function format. A multivariate system is then built from individual transfer functions, creating a matrix that serves as the nominal plant in an H-Infinity robust control algorithm. The controller’s main objective is to track and maintain hybrid operational constraints in the fuel cell’s cathode airflow, and the turbo machinery states of temperature and speed, under transient disturbances. This algorithm is then tested on a Simulink/MatLab platform for various perturbations of load and fuel cell heat effluence.

30 DIRECT ENERGY CONVERSION↗

Examination of the effect of system pressure ratio and heat recuperation on the efficiency of a coal based gas turbine fuel cell hybrid power generation system with CO2 capture

This paper examines two coal-based hybrid configurations that employ separated anode and cathode streams for the capture and compression of CO2. One configuration uses a standard Brayton cycle, and the other adds heat recuperation ahead of the fuel cell. Results show that peak efficiencies near 55% are possible, regardless of cycle configuration, including the cost in terms of energy production of CO2 capture and compression. The power that is required to capture and compress the CO2 is shown to be approximately 15% of the total plant power.

01 COAL, LIGNITE, AND PEAT↗

Effect of H2Se Exposure on Performance of Anode Supported SOFC

Combined coal gasification / solid oxide fuel cell plants are being pursued with the goal of achieving an integrated plant output efficiency of >50% with CO2 separation. Performance and degradation must be determined for SOFCs operated on syngas containing trace inorganic species in order to achieve the goals of peak efficiency performance and long lifetime, and to help focus cleanup efforts on the most deactivating species. In this study we investigated the performance of an anode supported SOFC operated at 800°C and 0.25A/cm2 and fuelled with simulated syngas containing H2Se at 5ppm and 0.5ppm. Initial experiments at 5ppm H2Se produced an initially sharp decrease in cell voltage output of 7% from 0.77 V to 0.72 V. The sharp decrease was followed by a more gradual decline in cell voltage at a rate of 610 %/1000hr for approximately 23 hours. By comparison, the cell exposed to 0.5 ppm H2Se showed no initial sharp decrease in performance from its initial voltage of 0.73 V. Prolonged exposure produced a voltage output decline at a rate of 63 %/1000hr for approximately 120 hours. The results indicate that H2Se degrades cell performance at concentrations as low as 0.5 ppm, but that the total degradation stabilizes depending on the trace species concentration.

Gerdes, K R↗

Calculating the Energy Cost of CO 2 Removal in a Coal Based Gas Turbine Fuel Cell Hybrid Power Generation System with an Isolated Anode Stream

In recent years there has been significant interest in identifying carbon capturing technologies that can be applied to fossil fuel power generation plants.CO 2 capture technologies seek to reduce the amount of CO 2 that would normally be emitted into the atmosphere from the daily operation of these plants. In terms of system efficiency and operating costs, this carbon capture is expensive. Further, the additional equipment that would be used to capture CO 2 emissions greatly adds to the complexity of the system. There has also been significant interest in coal based gas turbine fuel cell hybrid power plants. A hybrid power plant can have much greater system efficiency than a normal gas turbine power plant because the heat that is normally unused in a standalone solid oxide fuel cell (SOFC) is recovered and used to drive a power producing turbine. It is thought that the increased system efficiency of the hybrid system might compensate for the increased expense of performing carbon capture. In order to provide some analytical insight on this tradeoff we present a 100 MW class coal fired gas turbine SOFC hybrid power generation system. The hybrid system operates at a pressure ratio of 6, and uses heat recuperation and cathode air recirculation to control the SOFC inlet temperature and the temperature change across the SOFC. A carbon capture scheme is added to this system in order to calculate the relative energy cost in terms of system efficiency due to CO 2 compression. The carbon capture is performed by burning the unused fuel from the SOFC in an isolated anode stream using pure O 2 injection. The resulting heat that is generated from this process is then used to drive a secondary turbine that is placed in the anode exhaust stream where more work is extracted. With an isolated anode stream, the products of combustion from this secondary combustion process are mostly water and carbon dioxide. The water by-product is then condensed out of the stream leaving a relatively high concentration of CO 2 . This is then compressed, and removed from the system. In this study we present power plant efficiency calculations for the performance of the hybrid system with the carbon capturing loop. Our results show the effects on system performance that result from a changing fuel utilization factor.

Vanosdol, J G↗

The effect of coal syngas containing AsH3 on the performance of SOFCs: Investigations into the effect of operational temperature, current density and AsH3 concentration

The performance of solid oxide fuel cells (SOFCs) using simulated coal-derived syngas, with and without arsine (AsH3), was studied. Anode-supported SOFCs were tested galvanostatically at 0.25 and 0.5Acm-2 at 750 and 800 °C with simulated coal syngas containing 0.1, 1, and 2 ppm AsH3. The tests with simulated coal syngas containing 1 ppm AsH3 show little degradation over 100 h of operation. The tests with simulated coal syngas containing 2 ppm AsH3 show some signs of degradation, however no secondary arsenide phases were found. Extended trial testing with 0.1 ppm AsH3 showed degradation as well as the formation of a secondary nickel arsenide phase in the anode of the SOFC.

01 COAL, LIGNITE, AND PEAT↗

Scaling a SOFC Gas Turbine Hybrid System to Meet a Range of Power Demand

In recent years there has been significant interest in using the heat generated from the normal operation of a solid oxide fuel cell (SOFC) to supplant the normal combustion process of a gas turbine system. By doing this a gas turbine fuel cell hybrid power generation system is formed. Because the heat produced by a SOFC is utilized by the turbine to produce work, the hybrid system can have an overall system efficiency that greatly exceeds those of either the stand alone SOFC system, or the stand alone gas turbine system. One of the most critical problems that need to be addressed in gas turbine fuel cell hybrid technology is temperature control. A hybrid system that is designed to operate efficiently for a given base load may not be easily extended to accommodate peek loads. In this paper a simple hybrid system configuration using a standard SOFC and a single compressor turbine pair is presented. This simple system is used to establish the effect that key configuration parameters have on system temperatures. The configuration model is then scaled over a range of fuel input and power output to show the limitations of the system. The system is modeled using the ASPEN Plus® simulation software with special modules to calculate fuel cell performance.

VanOsdol, J G↗

The Effect of Trace Coal Syngas Species on the Performance of a Solid Oxide Fuel Cell

Presently coal is the United States’ most economical fossil fuel and given the vast reserves the fuel will be used for years to come for power generation. However, with ever increasing scrutiny over coal fired power plant emissions, more efficient and cleaner power production processes are being sought. Gasification technology, along with new cleanup and sequestration technologies, allows for the environmentally benign use of coal for power production. High temperature fuel cells, especially solid oxide fuel cells (SOFCs), represent a technology that may be used to more efficiently and cleanly produce both power and heat using fossil fuels such as coal. The U.S. Department of Energy is currently investing in the development of both gasification and fuel cell technologies. Although SOFC contaminants such as H2S and HCl will be thoroughly cleaned from coal syngas (CSG) by warm gas cleanup (WGC) systems, the effect of trace coal syngas species which may slip through WGC systems has not been previously investigated. A major goal of the National Energy Technology Laboratory is to theoretically and experimentally investigate the effects of such trace coal syngas species in order to further the development of gasification and SOFC technologies for advanced power generation. Thermodynamic calculations were first used to determine which trace CSG species would form volatile compounds through WGC conditions. From this investigation it was concluded that Sb, As, Cd, Pb, Hg, P, and Se will form volatile compounds and potentially interact with the SOFC anode. Further thermodynamic calculations showed that Sb, As, and P could form secondary phases with the Ni contained in the SOFC anode. In order to experimentally determine the effects of these trace CSG species, an experimental test fixture was constructed that allows button cell SOFCs to be tested with a modeled CSG fuel including trace species. The effect of AsH3, PH3, and Hg trace CSG species on the performance of an anode supported SOFC were tested. This paper reports the results from these tests including in-situ electrochemical measurements and post trial material analyses.

Trembly, J P↗

Solid Oxide Fuel Cell Performance Using Metallic Interconnects Coated By Electroplating Methods

Electroplating of metal coatings, either single metals or alloy can be used as a method of forming spinel interconnect coatings for solid oxide fuel cell (SOFC) interconnects. Cell performance tests, using low cost metallic interconnects, coated with spinel coatings by electroplating methods is reported. Comparison of the performance of different spinel phases is made by operating “button” cells with the coated metallic interconnects used as current collectors on the cathode side. Discussion of the ease of deposition of the various spinel phases using simple DC and Pulse plating techniques will be reported. Post test analysis of the “button cells” and the interconnect materials will be accomplished by XRD, SEM and EDS. Correlations between the post test analysis data and the cell performance data will be made.