Search NASA⌕ Search

Engineering topics

Genetti, Victoria D.

Publications and source records attributed to Genetti, Victoria D..

Collaborative Study for Certification of Trace Elements in Uranium Ore Concentrate CRMs UCLO-1, UCHI-1, and UPER-1

Trace impurity patterns are important nuclear forensic signatures in uranium ore concentrates (UOCs) and Certified Reference Materials (CRMs) are used to validate the analysis methods employed by end users. Herein, we discuss the certification campaign for three new UOC CRMs from the National Research Council Canada: UCLO-1 (https://doi.org/10.4224/crm.2020.uclo-1), UCHI-1 (https://doi.org/10.4224/crm.2020.uchi-1), and UPER-1 (https://doi.org/10.4224/crm.2020.uper-1). This study involved 15 laboratories from 10 countries, using sector-field and (triple) quadrupole inductively-coupled plasma mass spectrometry to analyze 64 trace element impurities. We discuss the importance of the acids used for sample digestion, difficulties analyzing in a high uranium matrix, and data combination and uncertainty evaluation for this large dataset.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Certification of Uranium Isotope Amount Ratios in a Suite of Uranium Ore Concentrate Certified Reference Materials

Here, in this study, data from thirteen laboratories from around the world are presented for a successful certification of uranium isotope ratios in uranium ore concentrate (UOC) certified reference materials from the National Research Council Canada. Different mass spectrometric measurement principles (including SF-ICP-MS, quadruple ICP-MS, TIMS, MC-ICP-MS, SIMS and AMS) and measurement procedures were employed. In general, data from all sources exhibit good consistency with TIMS and MC-ICP-MS showing superior performance. The three candidate UOC CRMs (UCLO-1, UCHI-1 and UPER-1) have natural uranium isotope ratios with certified values of 0.5304(7) x 10 -4 , 0.5475(2) x 10 -4 and 0.5361(4) x 10 -4 for n( 234 U)/n( 238 U) and 0.007 2563(13), 0.007 2563(10) and 0.007 2542(11) for n( 235 U)/n( 238 U), respectively, with expanded uncertainty (k = 2) applicable to the last digit of the value given in the parentheses. Information values for n( 236 U)/n( 238 U) in these three CRMs, measured by AMS, are also provided: 10 x 10 -12 , 200 x 10 -12 and 22 x 10 -12 . The uncertainties of the proposed certified values of uranium isotope ratios in UOC CRMs are superior to available reference materials, and the values of n( 234 U)/n( 238 U) and n( 236 U)/n( 238 U) show significant variation among the three CRMs.

58 GEOSCIENCES↗