Search NASA⌕ Search

Engineering topics

Geng, Rongli

Publications and source records attributed to Geng, Rongli.

At least 19 records

Identifying Downtime Sources in CEBAF SRF Linac Systems for Improving Its Reliability

In this work, we will present some recent analysis of the reliability statistics of the CEBAF SRF linac systems. Based on the data collected by the existing Down Time Manager (DTM), the year-to-year downtime evolution trend of linac zones over the six-year period from FY18 to FY23 is established. An in-depth downtime analysis at a resolution beyond the linac zone level was carried out by introducing a new system hierarchy, consisting of the SRF linac sub-systems and components. This new paradigm was implemented in a pilot downtime study over the two-month period of CEBAF operation from 9/13/23 to 11/13/23, enabling localization of the responsible sub-systems (SRF, HPRF, LLRF, Beamline vacuum, Cryogenics, etc.) and hardware components (cavity, tuner, RF coupler, etc.) in the CEBAF SRF linac systems. Pinpointing downtime sources over long operation periods at the sub-systems and component levels holds the key to improving the CEBAF SRF systems reliability. It also helps identify areas of SRF technology development needed by future high-power high-reliability CW SRF linacs.

Hryhorenko, Oleksandr↗

Method and apparatus for removal of microscopic contaminant particulates from superconducting radio frequency cavities and cavity strings

A method and apparatus for removing microscopic contaminant particulates by high pressure liquid nitrogen jet cleaning from the inner surface of a superconducting radio frequency cavity or a string of multiple cavities and transporting the removed particulates out of the inner space enclosed by the cleaned surfaces. The cleaning method of the invention suppresses field emission, resulting in an increase of the usable accelerating gradient of the cavities and a reduction of the activated radioactivity in accelerator components around cavities.

Geng, Rongli↗

Reflective laser-based particle detector

A reflective laser-based particle detector for detecting contamination particles moving through a vacuum. Laser light is directed through a vacuum access window in the containment vessel and toward a reflective surface on an inner surface opposite the window. A photonic detector is positioned to monitor reflected laser from the opposite inner surface inside the vessel and is capable of detecting perturbations of the reflected light. The system makes use of optical interferometry techniques embodied as a photonic integrated circuit to detect the particles. The reflective laser-based system can be placed entirely outside the vacuum thereby avoiding the need for breaking the vacuum environment to check for accumulation of contaminant particles.

Xi, Wenze↗

Magnetic Flux Generated by Thermal Current in CEBAF 5-Cell Cavity System

The unloaded quality factor Q0 of many 5-cell CEBAF cavities were lowered by a factor of ~2 from their vertical qualification testing to their beam operation in CEBAF tunnel. Causes of this Q0 degradation were studied previously, including a more recent one addressing static fluxes arising from magnetic components near a 5-cell cavity. This paper reports on a preliminary study of the dynamic fluxes generated by a thermal current. Such a thermal current arises from the Seebeck effect and flows in closed loops formed by a niobium cavity and its surrounding tuner rods and liquid helium vessel that are made of stainless-steel. The behaviors of magnetic fluxes in response to various thermal profiles on a 5-cell CEBAF cavity with integrated tuner rods were studied in a JLAB VTA dewar. An outcome of this study is a proposed cool-down procedure for eliminating the thermal current generated magnetic fluxes around 5-cell cavities placed in CEBAF tunnels. This procedure may be useful to improve cavity Q0 in a cost-effective manner, which in turn saves cryogenic expenditures for sustaining CEBAF operation.

Geng, Rongli↗

An Innovative Nb3Sn Film Approach and Its Potential for SRF Applications

A novel electro-chemical technique to produce Nb3Sn films on Nb substrates was developed and optimized at Fermilab. The Nb3Sn phase is obtained in a two-electrode cell, by electrodeposition from aqueous solutions of Sn layers and Cu intermediate layers onto Nb substrates. Subsequent thermal treatments in inert atmosphere are realized at a maximum temperature of 700°C to obtain the Nb3Sn superconducting phase. Several superconduct-ing Nb3Sn films were obtained on Nb substrates by study-ing and optimizing most parameters of the electro-plating process. Samples were characterized at Fermilab, NIMS, KEK and JLAB, including EPMA analyses, DC and in-ductive tests of critical temperature Tc0, and lower critical field Hc1(4.2 K) by SQUID. In parallel to sample devel-opment and fabrication at FNAL, at JLAB and KEK effort was put into etching and electro-polishing techniques adequate to remove the Cu and bronze phases from the samples’ outer surface. This is necessary prior to meas-urements at JLAB of the surface impedance of flat sam-ples in a setup that make use of an RF host cavity.

Barzi, E. Z.↗

Sensitivity of Surface Resistance to Trapped Flux in High-Purity Large-Grain Niobium

Surface resistance arising from trapped flux is experimentally measured, by which the sensitivity to trapped flux is derived. Measurements are carried out with single-cell L-band SRF cavities made of high-purity large-grain niobium materials, immersed in a uniform externally applied magnetic field generated by a solenoid with its axis overlapping the cavity axis. The surface resistance is found by using the standard technique for Q0 measurement and the customary G/Q0 analysis. Q0 values at a fixed low surface field are used. The trapped flux is found by measuring flux densities at a selected location using a single-axis fluxgate magnetometer attached to the cavity outer surface: Ba*[1-(Bsc-Bnc)/(Bsc0-Bnc)], where Ba is the applied external field, Bnc and Bsc is the local flux density measured just above and below Tc, respectively, during a field-cooling of the cavity and afterwards its Q0 is measured, Bsc0 is measured in a separate zero-field-cooling while the cavity being kept in the same location after turning on the identical applied field Ba at a temperature well below Tc . Several magnetometers are placed at various locations. It is found that the sensitivity to trapped flux in high-purity large-grain niobium to be 1.9 n?/µT on average. This is to be compared to 3-9 n?/µT in high purity fine-grain niobium and 10-50 n?/µT in nitrogen-doped high-purity niobium reported by other groups. We will discuss the measurement results as well as the measurement techniques.

Geng, Rongli↗

Field Emission in Superconducting Accelerators: Instrumented Measurements for Its Understanding and Mitigation

Several new accelerator projects are adopting superconducting accelerator technology. When accelerating cavities maintain high RF gradients, field emission, the emission of electrons from cavity walls, can occur and may impact operational cavity gradient, radiological environment via activated components, and reliability. In this talk, we will discuss instrumented measurements of field emission from the two 1.1 GeV superconducting continuous wave (CW) linacs in CEBAF. The goal is to improve the understanding of field emission sources originating from cryomodule production, installation and operation. Such basic knowledge is needed in guiding field emission control, mitigation, and reduction toward high gradient and reliable operation of superconducting accelerators.

Geng, Rongli↗

OPERATION OF THE CEBAF 100 MV CRYOMODULES

The Continuous Electron Beam Accelerator Facility (CEBAF) 12 GeV upgrade reached its design energy in December of 2015. Since then CEBAF has been deliver-ing 12 GeV beam to experimental Hall D and 11 GeV to experimental halls A and B in support of Nuclear physics. To meet this energy goal, ten new 100 MV cryomodules (80 cavities) and RF systems were installed in 2013. The superconducting RF cavities are designed to operate CW at a maximum accelerating gradient of 19.3 MV/m. To support the higher gradients and higher QL (~ 3×107) op-erations, the RF system uses 13 kW klystrons and digital LLRF to power and control each cavity. This paper re-ports on the C100 operation and optimization improve-ments of the RF system and cryomodules.

Hovater, James↗

Impact of remanent magnetic field on the heat load of original CEBAF cryomodule

The heat load of the original cryomodules for the CEBAF accelerator is ~50% higher than the target value of 100 W at 2.07 K for refurbished cavities operating at an accelerating gradient of 12.5 MV/m. This issue is due to the quality factor of the cavities being ~50% lower in the cryomodule than when tested in a vertical cryostat, even at low RF field. Previous studies were not conclusive about the origin of the additional losses. We present the results of a systematic study of the additional losses in a five-cell cavity from a decommissioned cryomodule after attaching components, which are part of the cryomodule, such as the cold tuner, the He tank and the cold magnetic shield, prior to cryogenic testing in a vertical cryostat. Flux-gate magnetometers and temperature sensors are used as diagnostic elements. Different cool-down procedures and tests in different residual magnetic fields were investigated during the study. Here, three flux-gate magnetometers attached to one of the cavities installed in the refurbished cryomodule C50-12 confirmed the hypothesis of high residual magnetic field as a major cause for the increased RF losses.

43 PARTICLE ACCELERATORS↗

Root Causes of Field Emitters in SRF Cavities Placed in CEBAF Tunnel

It has been suspected that appearance of new field emitters can occur in SRF cavities after their placement in accelerator tunnel for long term beam operation. This apparently has been the case for CEBAF. However, no physical evidence has been shown in the past. In this contribution, we will report on the recent results concerning the root cause of field emitters in SRF cavities placed in CEBAF tunnel. We will discuss these results in the context of high-reliability and low-cryogenic-loss operation of CEBAF.

Geng, Rongli↗

Observation of Stable Low Surface Resistance in Large-Grain Niobium SRF Cavities

Low surface resistance, or high unloaded quality factor (Q0), superconducting radio frequency (SRF) cavities are being pursued actively nowadays as their application in large-scale CW SRF accelerators can save capital and operational cost in cryogenics. There are different options in realization of such cavities. One of them is the large-grain (LG) niobium cavity. In this contribution, we present new experimental results in evaluation of LG niobium cavities cooled down in the presence of an external magnetic field. High Q0 values are achieved even with an ambient magnetic field of up to 100 mG. More over, it is observed that these high Q0 values are super-robust against repeated quench, literally not affected at all after the cavity being deliberately quenched for hundreds of times in the presence of an ambient magnetic field of up to 200 mG.

Geng, Rongli↗

Nature and implication of found actual particulates on the inner surface of cavities in a full-scale cryomodule previously operated with beam

Field emission in an SRF cavity is often the result of small foreign particulates lodging on the cavity inner surface. To avoid these particulate field emitters, careful cleaning and handling of individual cavities and clean room assembly of cavity strings are common practice. Despite these elaborate processes, some particulates persist to stay on the final surface of a beam-ready cavity. Moreover, as will be shown in this contribution, new particulates accumulate after a cryomodule is placed in the accelerator tunnel. The nature of these accumulated particulates on the inner surface of a beam-accelerating cavity is largely unknown for two reasons: (1) lack of access to such surfaces; (2) lack of a workable procedure for investigation without destroying the cavity. In this contribution, we report the first study on found actual particulates on the inner surface of 5-cell CEBAF cavities in a full-scale cryomodule previously operated with beam. The nature of the studied particulates is presented. The implication of the findings will be discussed in view of reliable and efficient operation of CEBAF and future large-scale SRF accelerators.

Geng, Rongli↗

Quench Studies of Six High Temperature Nitrogen Doped 9 Cell Cavities for Use in the LCLS-II Baseline Prototype Cryomodule at Jefferson Laboratory

Jefferson Lab (JLab) processed six nine-cell cavities as part of a small-scale production for LCLS-II cavity processing development utilizing the promising nitrogen-doping process. Various nitrogen-doping recipes have been scrutinized to optimize process parameters with the aim to guarantee an unloaded quality factor (Q_0) of 2.7∙10 10 at an accelerating field (Eacc) of 16 MV/m at 2.0 K in the cryomodule. During the R&D phase the characteristic Q0 vs. Eacc performance curve of the cavities has been measured in JLab’s vertical test area at 2 K. The findings showed the characteristic rise of the Q0 with Eacc as expected from nitrogen-doping. Initially, five cavities achieved an average Q0 of 3.3·10 10 at the limiting Eacc averaging to 16.8 MV/m, while one cavity experienced an early quench accompanied by an unusual Q_0 vs. Eacc curve. The project accounts for a cavity performance loss from the vertical dewar test (with or without the helium vessel) to the horizontal performance in a cryomodule, such that these results leave no save margin to the cryomodule specification. Consequently, a refinement of the nitrogen-doping has been initiated to guarantee an average quench field above 20 MV/m without impeding the Q_0. This paper covers the refinement work performed for each cavity, which depends on the initial results, as well as a quench analysis carried out before and after the rework during the vertical RF tests as far as applicable.

43 PARTICLE ACCELERATORS↗