Guided Resilience Self Assessment Application

Reliable electricity access is vital for everything from hospitals to national security. When grid disturbances occur, it is crucial to minimize the amount of time it takes to recover. Grid resiliency considers both the preparation for and recovery from high-impact low-frequency disturbances (HILF) such as weather events and cyber attacks. The Department of Energy (DOE) Wind Energy Technologies Office (WETO) funds the multi-laboratory Microgrids, Infrastructure Resilience, and Advanced Control Launchpad (MIRACL) project to investigate technologies to support and grow distributed wind. Researchers at Idaho National Laboratory (INL) contribute to resilience and cybersecurity efforts for the project, and have produced a resilience framework to evaluate system resilience based on individual system specifications. In order to make this framework easy for anyone to apply, I have coded a web application that allows users to input their power system qualities, goals, and perceived risks and then receive suggestions on how to improve their grid resiliency. The web application follows the seven steps in the planning stage of the framework process, allowing the user to input information about their grid and select from common goals, metrics, and hazards, as well as add their own. The application currently provides information about how to complete each step, requiring minimal prior knowledge of the framework. Future work for this application will include allowing the user to submit line drawings of their system and incorporate modeling tools so that the hazard simulations of applying the framework is completed for the user.

97 MATHEMATICS AND COMPUTING↗

Cybersecurity Guide for Distributed Wind Presentation

This presentation communicates information about the MIRACL project Resilience Metrics report and Resilience Framework report. It was created for the 2021 MIRACL advisory board meeting. Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This presentation is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Resilience Metrics and Framework for Distributed Wind Presentation

This presentation communicates information about the MIRACL project Resilience Metrics report and Resilience Framework report. It was created for the 2021 MIRACL advisory board meeting. We propose a three-tiered approach for the resilience framework. At the top level, we consider the time horizons on which resilience will be evaluated and executed. At the middle level, we consider the core functions of resilience, which span across the time horizons. At the lower level, we consider the process steps that correspond to implementing practices for resilience in each of the core functions. The framework considers three time horizons in order to enable organizations to assess and improve their system’s resilience throughout its lifecycle. We call these time horizons the planning, operational, and future stages. The planning stage uses organizational needs and current system evaluation to prepare for potential hazards. The operational stage seeks to execute responses to hazards as prudently and efficiently as possible to maintain system resilience. The future stage seeks to improve on current system resilience and feeds back into the planning stage to promote continuous improvement. While all three time horizons are important when considering a specific topic, the planning and evaluation phase (i.e., what is done in advance of the event) is critical in defining a system’s resilience characteristics and in outlining how a system responds to an event. This framework intentionally emphasizes the planning stage to highlight the overarching emphasis of this effort, not to imply that the other two time-related horizons (i.e., operational and change the future) are less important. The core functions in the framework are identify, prepare, detect, adapt, and recover. These five functions stem from a rigorous analysis of definitions used across the industry, and they represent the core capabilities that an organization must have to enable lifecycle resilience. Within each core function, process steps are described that help walk an organization through the information gathering, evaluation, decision-making, and implementation processes they will need to ensure their resilience goals are maintained throughout the system and the system lifecycle. Also highlighted in the figure is the concept that a resilience framework should be cyclical in nature. Because a system’s resilience is based on finite resources and time, it must continually evolve through this framework’s risk management and capital investment steps at an appropriate level of scope and pace.

17 WIND ENERGY↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

IEEE/CIGRE standards provide a base for overhead transmission line ratings Steady State Ampacity industry standard for Static Ratings using conservative environmental assumptions Measurement of many types of sensors provide a possibility to provide more capacity as a time varying capability Direct sensors of line temperature, tension, or sag provide critical, location specific information. Require complex transformation to determine line ampacity rating Are direct measurements sensors placed at key location(s)? Testing and careful calibration of sensors required Need to understand impact of uncertainties on sensors/measurements/ and forecasts

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Computational Fluid Dynamics to Assess Dynamic Line Rating in Southern Idaho

The overall goal of the study is to combine computational fluid dynamics (CFD) simulations with weather data that is collected over a 1-year long period across southern Idaho to calculate the dynamic line ratings (DLR) of several transmission lines. These ratings can be compared to the static rating assumptions to show the potential for additional current carrying capacity along transmission lines through account for additional effects of convective cooling from the wind. The region of interest is quite large, sized at 144 km by 98 km; in order to cover this large region, the CFD simulations are split into four separate regions of over 80 million computational cells each. The weather data that was collected suggest initial assumptions used to make the static ratings were vastly over predicted with regards to summer temperatures and solar irradiance. The weather data is ran through the General Line Ampacity State Solver (GLASS) tool that was developed by Idaho National Laboratory (INL) to parse large quantities of weather data across thousands of transmission midpoint spans in the region. For shorter lines, the dynamic line ratings often show large improvement over static ratings. The case study here shows over 95% of the time DLR values are above static values on the short transmission lines. However, for long lines, a conundrum occurs, where due to the large number of weather stations associated with the line, there is often a single weather station which may read local wind speeds of zero. This often defaults the line rating to be limited by natural convective cooling and does not show as much improvement over static as might be expected from the weather data if DLR calculations are used with a minimum ampacity across all midpoints. Other methods with transient state calculations should be utilized for long lines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Concurrent Wind Cooling in Power Transmission Lines

Idaho National Laboratory and the Idaho Power Company, with collaboration from Idaho State University, have been working on a project to monitor wind and other environmental data parameters along certain electrical transmission corridors. The combination of both real-time historical weather and environmental data is being used to model, validate, and recommend possibilities for dynamic operations of the transmission lines for power and energy carrying capacity. The planned results can also be used to influence decisions about proposed design criteria for or upgrades to certain sections of the transmission lines.

09 BIOMASS FUELS↗