Search NASA⌕ Search

Engineering topics

Geoghegan, Patrick J

Publications and source records attributed to Geoghegan, Patrick J.

Neutron imaging of diabatic two-phase flows relevant to air conditioning

The design of the evaporator of an air conditioning system relies heavily on heat transfer coefficients and pressure drop correlations that predominantly involve an estimate of the changing void fraction and the underlying two-phase flow regime. These correlations dictate whether the resulting heat exchanger is oversized or not and the amount of refrigerant charge necessary to operate. The latter is particularly important when dealing with flammable or high GWP refrigerants. Traditional techniques to measure the void fraction and visualize the flow are either invasive to the flow or occur downstream of the evaporator, where some of the flow distribution will have changed. Neutron imaging has the potential to visualize two-phase flow in-situ where an aluminium heat exchanger structure becomes essentially transparent to the penetrating neutrons. The subatomic particles are attenuated by the passing refrigerant flow. The resulting image may be directly related to the void fraction and the overall picture provides a clear insight into the flow regime present. This work presents neutron images of the refrigerant Isopentane as it passes through the flow channels of an aluminium evaporator at flowrates relevant to air conditioning. The flow in a 4mm square macro channel is compared to that in a 250 m by 750 m rectangular microchannel in terms of void fraction and regime. All neutron imaging experiments were conducted at the High Flux Isotope Reactor, an Oak Ridge National Laboratory facility

Geoghegan, Patrick J↗

European Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater

High efficiency gas-burning hot water heating takes advantage of a condensing heat exchanger to deliver improved combustion efficiency over a standard non-condensing configuration. The water heating is always lower than the gas heating value. In contrast, Gas Absorption Heat Pump (GAHP) hot water heating combines the efficiency of gas burning with the performance increase from a heat pump to offer significant gas energy savings. An ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. In comparison with air source electric heat pumps, the absorption system can maintain higher coefficients of performance in colder climates. In this work, a GAHP commercial water heating system was compared to a condensing gas storage system for a range of locations and climate zones across Europe. The thermodynamic performance map of a single effect ammonia-water absorption system was used in a building energy modeling software that could also incorporate the changing ambient air temperature and water mains temperature for a specific location, as well as a full-service restaurant water draw pattern.

Sharma, Vishaldeep↗

Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater Part 1: Southern and South Central Climate Zones

Commercial hot water heating accounts for approximately 0.78 Quads of primary energy use with 0.44 Quads of this amount from natural gas fired heaters. An ammonia-water based commercial absorption system, if fully deployed, could achieve a high level of savings, much higher than would be possible by conversion to the high efficiency nonheat-pump gas fired alternatives. In comparison with air source electric heat pumps, the absorption system is able to maintain higher coefficients of performance in colder climates. The ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. A thermodynamic model of a single effect ammonia-water absorption system for commercial space and water heating was developed, and its performance was investigated for a range of ambient and return water temperatures. This allowed for the development of a performance map which was then used in a building energy modeling software. Modeling of two commercial water heating systems was performed; one using an absorption heat pump and another using a condensing gas storage system. The energy and financial savings were investigated for a range of locations and climate zones in the southern and south central United States. A follow up paper will analyze northern and north/central regions. Results showed that the system using an absorption heat pump offers significant savings.

Geoghegan, Patrick J↗

Neutron Imaging Calibration to Measure Void Fraction

Void fraction is an intuitive parameter that describes the fraction of vapor in a two-phase flow. It appears as a key variable in most heat transfer and pressure drop correlations used to design evaporating and condensing heat exchangers, as well as determining charge inventory in refrigeration systems. Void fraction measurement is not straightforward, however, and assumptions on the invasiveness of the measuring technique must be made. Neutron radiography or neutron imaging has the potential to be a truly non-invasive void fraction measuring technique but has until recently only offered qualitative descriptions of two-phase flow, in terms of flow maldistributions, for example. This paper describes the calibration approach necessary to employ neutron imaging to measure steady-state void fraction. Experiments were conducted at the High Flux Isotope Reactor (HFIR) Cold Guide 1D neutron imaging facility at Oak Ridge National Laboratory (ORNL), Oak Ridge, TN, USA.

42 ENGINEERING↗

Neutron Imaging of a Two-Phase Refrigerant Flow

Void fraction remains a crucial parameter in understanding and characterizing two-phase flow. It appears as a key variable in both heat transfer and pressure drop correlations of two-phase flows, from the macro to micro- channel scale. Void fraction estimation dictates the sizing of both evaporating and condensing phase change heat exchangers, for example. In order to measure void fraction some invasive approach is necessary. Typically, visualization is achieved either downstream of the test section or on top by machining to expose the channel. Both approaches can lead to inaccuracies. The former assumes the flow will not be affected moving from the heat exchanger surface to the transparent section. The latter distorts the heat flow path. Neutron Imaging can provide a non-invasive measurement because metals such as Aluminum are essentially transparent to neutrons. Hence, if a refrigerant is selected that provides suitable neutron attenuation; steady-state void fraction measurements in two-phase flow are attainable in-situ without disturbing the fluid flow or heat flow path. Neutron Imaging has been used in the past to qualitatively describe the flow in heat exchangers in terms of maldistributions without providing void fraction data. This work is distinguished from previous efforts because the heat exchanger has been designed and the refrigerant selected to avail of neutron imaging. This work describes the experimental flow loop that enables a boiling two-phase flow; the heat exchanger test section and downstream transparent section are described. The flow loop controls the degree of subcooling and the refrigerant flowrate. Heating cartridges embedded in the test section are employed to control the heat input. Neutron-imaged steady-state void fraction measurements are captured and compared to representative high-speed videography captured at the visualization section. This allows a qualitative comparison between neutron imaged and traditional techniques. The measurements are also compared to correlations in the literature. Preliminary void fraction images from a macro-channel flow are presented, consisting of 1 channel, 4mm wide, 4mm high and 83.32mm long. Flow regime identification is examined. The experiments were conducted at the High Flux Isotope Reactor (HFIR) Cold Guide 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA.

Geoghegan, Patrick J↗

SIMULATION AND MOCKUP OF SNS JET-FLOW TARGET WITH WALL JET FOR CAVITATION DAMAGE MITIGATION

Pressure waves created in liquid mercury pulsed spallation targets at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory induce cavitation damage on the stainless steel target container. The cavitation damage is thought to limit the lifetime of the target for power levels at and above 1 MW. Severe through-wall cavitation damage on an internal wall near the beam entrance window has been observed in spent-targets. Surprisingly though, there is very little damage on the walls that bound an annular mercury channel that wraps around the front and outside of the target. The mercury flow through this channel is characterized by smooth, attached streamlines. One theory to explain this lack of damage is that the uni-directional flow biases the direction of the collapsing cavitation bubble, reducing the impact pressure and subsequent damage. The theory has been reinforced by in-beam separate effects data. For this reason, a second-generation SNS mercury target has been designed with an internal wall jet configuration intended to protect the concave wall where damage has been observed. The wall jet mimics the annular flow channel streamlines, but since the jet is bounded on only one side, the momentum is gradually diffused by the bulk flow interactions as it progresses around the cicular path of the target nose. Numerical simulations of the flow through this jet-flow target have been completed, and a water loop has been assembled with a transparent test target in order to visualize and measure the flow field. This paper presents the wall jet simulation results, as well as early experimental data from the test loop.

cavitation mercury target jet flow wall jet↗

Rotating Target Development for SNS Second Target Station

A rotating target for the second target station (STS) at SNS has been identified as an option along with a mercury target. Evaluation of the rotating target alternative for STS has started at 1.5 MW which is considered an upper bound for the power. Previous preconceptual design work for a 3 MW rotating target is being modified for the lower power level. Transient thermal analysis for a total loss of active water cooling has been done for a simplified 2D model of the target and shielding monolith which shows that peak temperatures are well below the level at which tungsten vaporization by steam could exceed site boundary dose limits. Design analysis and integration configuration studies have been done for the target-moderator-reflector assembly which maximizes the number of neutron beam lines and provides for replacement of the target and moderators. Target building hot cell arrangement for this option will be described. An option for operation in rough vacuum without a proton beam window using Ferro fluid seals on a vertical shaft is being developed. A full scale prototypic drive module based on the 3 MW preconceptual design has been fabricated and successfully tested with a shaft and mock up target supplied by the ESS-Bilbao team. Overall planning leading to decision between mercury and the rotating target in 2011 will be discussed

43 PARTICLE ACCELERATORS↗

BEAM STOP DESIGN METHODOLOGY AND DESCRIPTION OF A NEW SNS BEAM STOP

The design of accelerator components such as magnets, accelerator cavities and beam instruments tends to be a fairly standardized and collective effort within the particle accelerator community with well established performance, reliability and, in some cases, even budgetary criteria. Beam stop design, by contrast, has been comparatively subjective historically with much more general goals. This lack of rigor has lead to a variety of facility implementations with limited standardization and minimal consensus on approach to development within the particle accelerator community. At the Spallation Neutron Source (SNS), for example, there are four high power beam stops in use, three of which have significantly different design solutions. This paper describes the design of a new off-momentum beam stop for the SNS. The technical description of the system will be complemented by a discussion of design methodology. This paper presented an overview of the new SNS HEBT off-momentum beam stop and outlined a methodology for beam stop system design. The new beam stop consists of aluminium and steel blocks cooled by a closed-loop forced-air system and is expected to be commissioned this summer. The design methodology outlined in the paper represents a basic description of the process, data, analyses and critical decisions involved in the development of a beam stop system.

36 MATERIALS SCIENCE↗