Impact of measured spectrum variation on solar photovoltaic efficiencies worldwide
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Georghiou, George E..
Explore the source record for details and available documents.
In photovoltaic power ratings, a single solar spectrum, AM1.5, is the de facto standard for record laboratory efficiencies, commercial module specifications, and performance ratios of solar power plants. More detailed energy analysis that accounts for local spectral irradiance, along with temperature and broadband irradiance, reduces forecast errors to expand the grid utility of solar energy. Here, ground-level measurements of spectral irradiance collected worldwide have been pooled to provide a sampling of geographic, seasonal, and diurnal variation. Applied to nine solar cell types, the resulting divergence in solar cell efficiencies illustrates that a single spectrum is insufficient for comparisons of cells with different spectral responses. Cells with two or more junctions tend to have efficiencies below that under the standard spectrum. Silicon exhibits the least spectral sensitivity: relative weekly site variation ranges from 1% in Lima, Peru to 14% in Edmonton, Canada.
Abstract not provided.
Abstract Fault detection and classification in photovoltaic (PV) systems through real‐time monitoring is a fundamental task that ensures quality of operation and significantly improves the performance and reliability of operating systems. Different statistical and comparative approaches have already been proposed in the literature for fault detection; however, accurate classification of fault and loss incidents based on PV performance time series remains a key challenge. Failure diagnosis and trend‐based performance loss routines were developed in this work for detecting PV underperformance and accurately identifying the different fault types and loss mechanisms. The proposed routines focus mainly on the differentiation of failures (e.g., inverter faults) from irreversible (e.g., degradation) and reversible (e.g., snow and soiling) performance loss factors based on statistical analysis. The proposed routines were benchmarked using historical inverter data obtained from a 1.8 MWp PV power plant. The results demonstrated the effectiveness of the routines for detecting failures and loss mechanisms and the capability of the pipeline for distinguishing underperformance issues using anomaly detection and change‐point (CP) models. Finally, a CP model was used to extract significant changes in time series data, to detect soiling and cleaning events and to estimate both the performance loss and degradation rates of fielded PV systems.
Not Available
Accurate quantification of photovoltaic (PV) system degradation rate (R D ) is essential for lifetime yield predictions. Although R D is a critical parameter, its estimation lacks a standardized methodology that can be applied on outdoor field data. The purpose of this paper is to investigate the impact of time period duration and missing data on R D by analyzing the performance of different techniques applied to synthetic PV system data at different linear R D patterns and known noise conditions. The analysis includes the application of different techniques to a 10-year synthetic dataset of a crystalline Silicon PV system, with emulated degradation levels and imputed missing data. Here, the analysis demonstrated that the accuracy of ordinary least squares (OLS), year-on-year (YOY), autoregressive integrated moving average (ARIMA) and robust principal component analysis (RPCA) techniques is affected by the evaluation duration with all techniques converging to lower R D deviations over the 10-year evaluation, apart from RPCA at high degradation levels. Moreover, the estimated R D is strongly affected by the amount of missing data. Filtering out the corrupted data yielded more accurate R D results for all techniques. It is proven that the application of a change-point detection stage is necessary and guidelines for accurate R D estimation are provided.
Abstract not provided.
Abstract not provided.
A main challenge for integrating the intermittent photovoltaic (PV) power generation remains the accuracy of day-ahead forecasts and the establishment of robust performing methods. The purpose of this work is to address these technological challenges by evaluating the day-ahead PV production forecasting performance of different machine learning models under different supervised learning regimes and minimal input features. Specifically, the day-ahead forecasting capability of Bayesian neural network (BNN), support vector regression (SVR), and regression tree (RT) models was investigated by employing the same dataset for training and performance verification, thus enabling a valid comparison. The training regime analysis demonstrated that the performance of the investigated models was strongly dependent on the timeframe of the train set, training data sequence, and application of irradiance condition filters. Furthermore, accurate results were obtained utilizing only the measured power output and other calculated parameters for training. Consequently, useful information is provided for establishing a robust day-ahead forecasting methodology that utilizes calculated input parameters and an optimal supervised learning approach. Finally, the obtained results demonstrated that the optimally constructed BNN outperformed all other machine learning models achieving forecasting accuracies lower than 5%.
Not Available
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Although common practice for estimating photovoltaic (PV) degradation rate (RD) assumes a linear behavior, field data have shown that degradation rates are frequently nonlinear. This article presents a new methodology to detect and calculate nonlinear RD based on PV performance time-series from nine different systems over an eight-year period. Prior to performing the analysis and in order to adjust model parameters to reflect actual PV operation, synthetic datasets were utilized for calibration purposes. A change-point analysis is then applied to detect changes in the slopes of PV trends, which are extracted from constructed performance ratio (PR) time-series. Once the number and location of change points is found, the ordinary least squares method is applied to the different segments to compute the corresponding rates. The obtained results verified that the extracted trends from the PR time-series may not always be linear and therefore, “nonconventional” models need to be applied. All thin-film technologies demonstrated nonlinear behavior whereas nonlinearity detected in the crystalline silicon systems is thought to be due to a maintenance event. A comparative analysis between the new methodology and other conventional methods demonstrated levelized cost of energy differences of up to 6.14%, highlighting the importance of considering nonlinear degradation behavior
A main challenge towards ensuring large-scale and seamless integration of photovoltaic systems is to improve the accuracy of energy yield forecasts, especially in grid areas of high photovoltaic shares. The scope of this paper is to address this issue by presenting a unified methodology for hourly-averaged day-ahead photovoltaic power forecasts with improved accuracy, based on data-driven machine learning techniques and statistical post-processing. More specifically, the proposed forecasting methodology framework comprised of a data quality stage, data-driven power output machine learning model development (artificial neural networks), weather clustering assessment (K-means clustering), post-processing output optimisation (linear regressive correction method) and the final performance accuracy evaluation. The results showed that the application of linear regression coefficients to the forecasted outputs of the developed day-ahead photovoltaic power production neural network improved the performance accuracy by further correcting solar irradiance forecasting biases. The resulting optimised model provided a mean absolute percentage error of 4.7% when applied to historical system datasets. Finally, the model was validated both, at a hot as well as a cold semi-arid climatic location, and the obtained results demonstrated close agreement by yielding forecasting accuracies of mean absolute percentage error of 4.7% and 6.3%, respectively. Finally, the validation analysis provides evidence that the proposed model exhibits high performance in both forecasting accuracy and stability.
This Special Issue entitled 'Performance Assessment and Condition Monitoring of Photovoltaic Systems for Improved Energy Yield', contains ten papers that discuss various aspects in performance assessment, thus bringing the reader up to date with the present state-of-the-art technologies. In particular, the following topics are addressed: system performance monitoring; operational analysis and design; solar forecasting.