Search NASA⌕ Search

Engineering topics

Geppert-Kleinrath, Hermann

Publications and source records attributed to Geppert-Kleinrath, Hermann.

At least 19 records

Technique for an improved and time-resolved carbon areal density measurement with a single channel diagnostic for inertial confinement fusion

Measurement of the areal density and velocity of the carbon ablator shell during peak burn in inertial confinement fusion give powerful information on the state of the ablator and where in the trajectory of implosion it reaches peak burn. Detailed comparison of the absolute densities and velocities of the carbon in implosions has been prevented by the limited ability to resolve shot-to-shot variation within a shot series or within a campaign. Here, a new approach using a single, ultra fast (~10 ps) gamma ray channel can massively reduce uncertainties and will provide insights on improvements to target and drive variables. Small improvements in these experimental design parameters may result in much greater yields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the gamma reaction history diagnostic for double-shell pusher areal density and reaction history measurements on the National Ignition Facility

The double-shell inertial confinement fusion campaign, which consists of an aluminum ablator, a foam cushion, a high-Z pusher (tungsten or molybdenum), and liquid deuterium–tritium (DT) fuel, aims for its first DT filled implosions on the National Ignition Facility (NIF) in 2024. The high-Z, high density pusher does not allow x-rays to escape the double-shell capsule. Therefore, nuclear diagnostics such as the Gamma Reaction History (GRH) diagnostic on the NIF are crucial for understanding high-Z implosion performance. To optimize the GRH measurement of fusion reaction history and the pusher’s areal density, the MCNP6.3-based forward model of the detector was built. When calculating the neutron-induced inelastic gamma ray production, the interaction of neutrons with the compressed fuel was additionally included. By folding the calculated gamma ray spectrum output and the previously calibrated GRH detector responses, the optimum set of GRH energy thresholds for measuring the pusher areal density is determined to be 2.9 and 6.3 MeV for DT double-shell experiments. In addition, the effect of the down-scattering of neutrons on the gamma ray spectrum, the minimum required yield for measurements, and the attenuation of the gamma rays through the pusher are analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NucD-25 Nuclear Diagnostics Development: NIS capability, Maximizing gamma ray dynamic range, (n,γ) measurements for carbon ρR [Slides]

The LANL Neutron Imaging team is preparing for NIS upgrades and novel capabilities with the advent of consistently higher yields at NIF. Novel scintillators, solid-state detectors, multiplexed imaging detectors, upgraded data acquisition systems, and camera testing are all areas in need of experimental study to further develop imaging capabilities and dynamic range at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First large capsule implosions in a frustum-shaped hohlraum

Here, we report on the first indirect-drive implosions driven by a dual conical frustum-shaped hohlraum denoted “frustraum” and the experimental tuning campaigns leading up to two layered implosions. The campaign used 1.2 and 1.4 mm inner radius high density carbon (HDC) capsules and represented the largest HDC capsules to be imploded on the National Ignition Facility via indirect drive. Several techniques were successfully implemented to control the Legendre mode 2 capsule symmetry of the implosions, including changing the wall angle of the frustraum, which is not possible with cylindrical hohlraums. A mode 4 feature was observed and its implications for hotspot mix discussed. Two layered implosions were conducted with 1.2 mm inner radius capsules, the latter of which achieved the highest layered capsule absorbed energy on the National Ignition Facility using only 1.74 MJ of laser energy. The layered implosion results, along with generalized Lawson parameters, suggest that increasing the energy absorbed by the capsule at the expense of long coast times makes it more challenging to achieve ignition and that further reducing coast time (time between end of laser pulse and bang time) closer to the 1 ns level is warranted to improve the areal density and make it easier to achieve the hotspot temperature, alpha heating, and yield amplification required for ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LANL diagnostics at NIF [Slides]

Nuclear Diagnostics are described at the National Ignition Facility (NIF) including Reaction History and Neutron Imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NucD-24 Nuclear Diagnostics Development: Time resolved 12 C-rhoR on GCD and NIS technology development for polar LOS and data quality [Slides]

The Neutron Imaging team is readying for the NIS2 polar LOS development and future improvements to data quality on all LOS given consistently higher yields at NIF. Next-gen nano guide scintillators for NIS2 and CMOS cameras to replace outdated CCDs will be studied. Digital image plates will be tested for better data quality on passive imaging systems. The transition into the ignition regime is expected to show a significant signature in the ablator areal density. In the marginal ignition regime, a decrease of 12C-rhoR (ablator areal density) is expected but once the burn propagation produces a shock and compresses the ablator the trend reverses. GCD with the PD-PMT can resolve this effect in the ablator areal density by a temporal shift in the carbon signal. To give quantitative results a calibration of the detector for the Hohlraum/TMP signal is needed. Shots using Al, Si, and Au pucks will yield the needed information to move forward with this project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas scintillation mitigation in gas Cherenkov detectors for inertial confinement fusion (invited)

Gas Cherenkov detectors provide a time resolved measurement of the fusion burn in inertial confinement fusion experiments. The fusion rate delivers critical benchmark figures, such as burn width and bang time. Recent detector improvements pushed temporal resolution to 10 ps to make burn width measurements on igniting targets possible. First high temporal resolution measurements using CO 2 gas fills had a background signal with a long decay length (tail), which was caused by gas scintillation. This gas scintillation limits the ability of the detector to resolve short burn width and high frequency features in the fusion rate measurements. A thorough investigation of the cause of the tail and mitigation options for gas scintillation is presented here. As a near-term resolution, neon gas is being used to extract fusion burn histories. Paths forward for the next generation of gas Cherenkov detectors are identified including the usage of oxygen as a Cherenkov medium.

47 OTHER INSTRUMENTATION↗

Capsule defects measurement [Slides]

Recent high yield shots a NIF showed that capsule defects are limiting shot performance. Voids in the capsule are not well understood in how they degrade yield performance. Recent simulations show that voids can reduce compressibility without any diagnostic signatures but reduced yield. In extreme cases loss of compression is expected. Up to 10,000 voids might be necessary to measure the different effects. Experiments using capsules with engineered defects can help guide simulations and improve our understanding of the physics involved. The knowledge gained can be applied to other problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NucD-23 Nuclear Diagnostics Development: The future of neutron imaging and gamma reaction history

The Neutron Imaging team has deployed novel, active detection systems along two lines of sight at NIF. Studies aimed to characterize NIS sensitivity to implosion shape will be carried out to further extend reconstruction capabilities. Additionally, an improved camera timing system that will reduce uncertainties stemming from bang time jitter will also be fielded. The NIF GRH data recording system is more then 10 years old needs to be updated. Bandwidth and noise are a key limiting factor for improving data quality. New high bandwidth and low noise components will be tested at OMEGA in advance before fielding the components at NIF.

42 ENGINEERING↗

A Novel High Frequency, High Bandwidth, Three Phase Mach Zehnder Optical Data Link [Slides]

Inertial Confinement Fusion (ICF) produces high yield, high bandwidth signals that must be sent over large distances. A three phase Mach Zehnder modulator system helps resolve many of the issues faced with measuring these signals. This setup requires a three step reconstruction program. The testing results from OMEGA show this setup was successful and is ready for fielding at Inertial Confinement Fusion, including the National Ignition Facility (NIF).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma Imaging on NIS3

Explore the source record for details and available documents.

Geppert-Kleinrath, Verena↗

Diagnosing Thermonuclear Burn in Fusion Implosions using Ultra-Fast Gas Cherenkov Detectors [Slides]

This presentations addresses these questions. What is fusion and what is ignition? How does LASER driven Inertial Confinement Fusion work? What can we measure and what does it tell us about fusion? How do Gas Cherenkov detectors work and what do they tell us? What are our plans for the future? In brief, the take away messages for this presentation are as follows: DT fusion reaction history provides crucial physics for ICF; gamma reaction history diagnostics are ready to resolve burn width on ignition shots; and GCDs have a lot of potential solving some of the questions related to fusion science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-pulse time resolved gamma ray spectroscopy of the advanced radiographic capability using gas Cherenkov diagnostics

The advanced radiographic capability located at the National Ignition Facility (NIF) uses high intensity, short pulse lasers to create bright photon sources for diagnosing high energy density experiments. There are radiographic needs for a multi-frame time-resolved MeV gamma diagnostic for experiments on the NIF with sub-nanosecond resolution. A series of experiments demonstrated measurements of MeV x-ray spectra resolved with a time separation of a few nanoseconds through the use of gas Cherenkov detectors. In this work, a two-pulse radiographic experiment found a 30% reduction in > 2.8 MeV photon flux compared to the first frame exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time resolved ablator areal density during peak fusion burn on inertial confinement fusion implosions

Near peak compression, inertial confinement fusion implosions release both deuterium–tritium (DT) fusion gamma rays and neutron induced gamma rays from carbon from the areal density of the remaining ablator shell. The gamma reaction history diagnostic makes a time resolved measurement of both. Across many recent implosions, the carbon gamma ray peak arrives systematically 11 ± 10 ps later compared to DT fusion burn. The timing shift is consistent with the carbon areal density increasing throughout the peak of the fusion burn, implying that the carbon portion of the capsule continues to converge. A model finds that the observed timing shift is consistent with a 4π averaged carbon ablator inward velocity of 80 μm/ns for the contemporary National Ignition Facility implosions. In this work, the timing shift is possibly related to the energy balance of the implosion, with the expectation that a high performing, igniting capsule would see the carbon gamma rays arrive before the DT fusion peak.

Nuclear fusion↗