Search NASA⌕ Search

Engineering topics

Gering, Kevin L.

Publications and source records attributed to Gering, Kevin L..

At least 19 records

Fast-charging lithium-ion batteries: Synergy of carbon nanotubes and laser ablation

Advancing lithium-ion battery (LiB) technology to achieve 10–15-min extreme fast charging (XFC) while maintaining high energy density and longevity poses a significant challenge. Addressing Li-plating is crucial, as it depletes useable Li, causing deterioration and safety issues. Here, this study explores a holistic approach incorporating Single-Wall Carbon Nanotubes (SWCNTs) and Laser Ablation (LA) to mitigate Li-plating while maintaining high charge acceptance under 10–15-min XFC. SWCNTs enhance the electrical conductivity and mechanical integrity of the positive electrode (PE), reducing overall cell overpotential at high charging rates. Concurrently, LA is applied to negative electrodes (NE) to reduce tortuosity of ion-diffusion pathways and increase surface wettability, improving Li-ion transport. Combining SWCNTs in the PE and LA on the NE, our experimental findings demonstrate a significant reduction in Li-plating and maintained high charge acceptance of ~84.33 % after 800 5C (12 min) charge cycles for cells having PE with ~3.3 mAh cm –2 and NE with 3.9 mAh cm –2 loadings. This study highlights the potential of combining SWCNTs and LA to address Li-plating in LiBs and opens new avenues for designing battery systems capable of achieving 10–15-min XFC.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods for managing energy storage operations

An energy storage device (ESD) manager determines charge conditions that result in charge-related aging of an energy storage device (ESD), such as a battery, cell, or the like. The ESD manager may determine charge-related costs for charge operations, which may quantify charge-related aging imposed by subjecting ESD to specified charge conditions. The ESD manager may evaluate and/or modify charge operations to reduce charge-related aging. The ESD manager may be further configured to model charge-related aging behavior over time and/or under variable charge conditions. The ESD manager may configure charge operations to ensure that charge-related performance loss remains below a threshold for a specified usage duration.

Gering, Kevin L.↗

Battery state-of-health diagnostics during fast cycling using physics-informed deep-learning

Rapid, in-situ Li-ion battery state-of-health (SOH) quantification is challenging. Li-ion battery aging can vary significantly with chemistry, operating conditions, cycling demands, electrode design, and operation history. As a cell ages, optimal and safe operating conditions need to be adapted to account for battery degradation by tracking critical aging modes such as loss-of-lithium-inventory (LLI), loss-of-active-material (LAM) in either electrode, and/or impedance rise. This manuscript describes a framework for identifying battery aging modes in-operando using fast-rate voltage charge/discharge responses. The framework uses a physically based Li-ion battery model to produce synthetic high-rate responses at aged states. The aging model is calibrated against experimental data from cells with different electrode loadings and cycled under a variety of fast-charging conditions (1 h, 15 min, 10 min, and 7 min charging). The synthetically generated high-rate responses at aged states are then used to train a deep-learning model to identify real cell state-of-health from fast charge/discharge battery voltage responses. The synthetically trained deep-learning model performance is validated by comparing to standard incremental capacity analysis and half-cell measurements. Finally, the framework demonstrates the benefits of using high-rate physics-based models to generate synthetic data for training deep-learning models.

25 ENERGY STORAGE↗

Battery data integrity and usability: Navigating datasets and equipment limitations for efficient and accurate research into battery aging

A tremendous commitment of resources is needed to acquire, understand and apply battery data in terms of performance and aging behavior. There are many state of performance (SOP) and state of health (SOH) metrics that are useful to guide alignment of batteries to end-use, yet how these metrics are measured or extracted can make the difference between usable, valuable datasets versus data that lacks the necessary integrity to meet baseline confidence levels for SOP/SOH quantification. This work will speak to 1) types of data that support SOP and SOH evaluations on mechanistic terms, 2) measurement conditions needed to assure high data integrity, 3) equipment limitations that can compromise data high fidelity, and 4) the impact of cell polarization on data quality. A common goal in battery research and field use is to work from a data platform that supports economical paths of data capture while minimizing down-time for battery diagnostics. An ideal situation would be to utilize data obtained during normal daily use (“pulses or cycles of convenience”) without stopping the daily duty cycles to perform dedicated SOP/SOH diagnostic routines. However, difficulties arise in trying to make use of daily duty cycle data (denoted as cycle-by-cycle, CBC) that underscores the need for standardization of conditions: temperature and duty cycles can vary over the course of a day and throughout a week, month and year; polarization can develop within an immediate cycle and throughout successive cycles as a hysteresis. If CBC data is envisioned as a data source to determine performance and aging trends, it should be recognized that polarization is a frequent consequence of CBC and thus makes it difficult to separate reversible and irreversible components to metrics such as capacity loss and resistance increase over aging. Since CBC conditions can have a major impact on data usability, we will devote part of this paper to CBC data conditioning and management. Differential analyses will also be discussed as a means to detect changing trends in data quality. Our target cell chemistries will be lithium-ion types NMC/graphite and LMO/LTO.

25 ENERGY STORAGE↗

Projecting Recent Advancements in Battery Technology to Next–Generation Electric Vehicles

Electric vehicles (EVs) have seen rapid growth in adoption over the last several years. Advancements to increase battery life and performance, policy shifts, and high charging rate are expected to further accelerate the development of next generation of EVs. Battery improvements continue to emerge, enabling increased driving range, total distance driven over the life of vehicles, and ability to charge at high rates. Herein, an analysis framework to provide insights into inclusive design metrics, such as specific energy of batteries, energy consumption of vehicles, and charging power infrastructure development, is developed. Various cell-level fast charge protocols to realistic battery designs to understand the infrastructure needs associated with achieving range replacement of 32.25 km min -1 (20 mi min -1 ) are also scaled. Additionally, by calculating scaled power and peak to average power ratio, it is found that there needs to be more distinct alignment between the research efforts focused at the cell level and what is being developed for EV charging infrastructure needs. Finally, impact of high direct current voltage architecture in next-generation EVs is discussed. The findings in this work provide an insight into recent advancements in battery technology to next-generation EVs.

20 mi/min↗

Developing extreme fast charge battery protocols – A review spanning materials to systems

Extreme fast charging (XFC) has become a focal research point in the lithium-battery community over the last several years. As adoption of electric vehicles increases, fast charging has become a key driver in enhancing consumer recharge experience. Recently, the research community has made significant improvements in developing charge protocols to support XFC. New charge protocol designs derived using a combination of advanced, physically derived models, and electrochemical and secondary characterization methods, increase charge acceptance and decrease aging. By coordinating these methods and modifying protocols to account for different material constraints, including lithium plating and cathode particle degradation, novel charge protocols have increased the energy accepted during charging by over 25% in 10 min and increased the charge acceptance prior to a constant-voltage step by approximately 3x. Here, we review several charge-protocol advances, aging factors which are enhanced by XFC and advances which will enable adoption of XFC capable vehicles. These advances include implementing machine learning and other detection algorithms to reduce and classify lithium plating, which is known to significantly degrade cell performance and reduce cell life. The review concludes by discussing full-system fast charge requirements, including electric vehicle service equipment needs for implementing XFC protocols.

25 ENERGY STORAGE↗

Impact of Electrode Thickness and Temperature on the Rate Capability of Li 4 Ti 5 O 12 /LiMn 2 O 4 Cells

Growing demand for stationary energy storage systems requires the development of low cost, long cycle life, safe batteries. Lithium-ion batteries (LiBs) utilizing Li 4 Ti 5 O 12 /LiMn 2 O 4 (LMO) cathode are promising candidates providing critical-material-free chemistry, high power capability, and long lifespan. However, their low energy density is a major drawback. In this work, we evaluate the rate performance of LTO/LMO cells fabricated with electrode loadings from 1.7 to 4.2 mAh cm -2 toward the development of high energy density and low cost LTO/LMO cells. The operating temperature is varied from 30 °C to 55 °C to evaluate the impact of electrode thickness vs temperature limitations on the electrode utilization. In addition, Newman modeling is performed to provide detailed understandings of the cell performance. Combining experimental and simulated results, we show the rate capability of the thicker electrodes is limited by the electrolyte transport. When the cells are discharged by applying pulsed current, Li + ion depletion is mitigated and the discharge capacity increases. Thus, high energy density LTO/LMO cells for BTMS applications can operate more efficiently when intermittent rest is applied. Finally, overcoming electrolyte transport limitations will be the key to enabling the development of high energy density LTO/LMO cells using thick electrodes.

25 ENERGY STORAGE↗

Methodologies for Design, Characterization and Testing of Electrolytes that Enable Extreme Fast Charging of Lithium-ion Cells

Selection, testing and validation of electrolyte candidates for Li-ion cells are discussed, based on a 10-minute target for extreme fast charge (XFC). A combination of modeling and laboratory measurements create a timely and synergistic approach to identifying candidate electrolyte formulations. Multi-solvent systems provide a balanced set of properties, wherein lower molecular-weight solvents offer reduced viscosity, increased species diffusivity, and mitigation of concentration polarization at high charge rates. Carefully selected formulations can exhibit peak conductivity and usable conductivity range of two to three times that of the baseline EC-EMC (3:7, wt.) + LiPF 6 . Candidates are also chosen based on stability and longevity within the cell environment. Lab testing coincides with property predictions from the Advanced Electrolyte Model (AEM) and a macro-scale cell model. Furthermore, cell testing utilized coin and pouch cells having NMC532 or NMC811 cathodes with graphite electrodes. Results indicate combinations of low-molecular weight solvents are key for fast-charge electrolytes as they extend the useful conductivity range to both low and higher salt concentrations, and possess higher self-diffusivities compared to conventional solvents. This reduces impacts from concentration polarization. The choice of electrolyte also influences the tendency for lithium metal deposition at the anode, as showcased by experimental and modeling results herein.

25 ENERGY STORAGE↗

Early Battery Performance Prediction for Mixed Use Charging Profiles Using Hierarchal Machine Learning

A key step limiting how fast batteries can be deployed is the time necessary to provide evaluation and validation of performance. Using data analysis approaches, such as machine learning, the validation process can be accelerated. However, questions on the validity of projecting models trained on limited data or simple cycling profiles, such as constant current cycling, to real-world scenarios with complex loads remains. Here, we present the ability to predict performance with less than 1.2% mean absolute percent error when trained on cells aged using complex electric vehicle discharge profiles, and either AC Level 2 charge or DC Fast charge profiles, using only the first 45 cycles, namely 5% of the total testing time. While error is low across the projections, this study also highlights that battery lifetime analysis using only cycling data may not extrapolate safely to certain real-world conditions due to the impact of calendar degradation.

25 ENERGY STORAGE↗

Systems and related methods for determining self-discharge currents and internal shorts in energy storage cells

Systems and methods for determining self-discharge currents in an energy storage cell and detecting internal shorts are disclosed. A system includes a DC voltage source configured to provide a constant test voltage selected to be less than an open-circuit voltage of an energy storage cell to the energy storage cell. The system also includes a current measuring device operably coupled between the DC voltage source and the energy storage cell, and control circuitry operably coupled to the current measuring device. A method includes applying the constant test voltage, and measuring the test current flowing between the DC voltage source and the energy storage cell until after the test current switches from a negative current to a positive current. The method also includes determining a self-discharge current of the energy storage cell by analyzing the measured test current with computational models that capture physical processes tied to the test methods.

25 ENERGY STORAGE↗

Using the Charge-Discharge Cycling of Positive Electrode Symmetric Cells to Find Electrolyte/Electrode Combinations with Minimum Reactivity

The effects of solvents, salts, electrolyte additives and surface coatings on LiNi 0.4 Mn 0.4 Co 0.2 O 2 (NMC442) or LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) have been probed using positive electrode Li-ion symmetric cells coupled with dV/dQ analysis. A robust symmetric cell design is presented which prevents hardware corrosion for over at least 800 hours of testing to 4.5 V vs. Li/Li + at 40°C. Positive electrode symmetric cells using uncoated positive electrode materials and 1M LiPF 6 EC:EMC 3:7 or 1M LiPF 6 EMC electrolyte rapidly developed high impedance and showed poor capacity retention. However, if 1% pyridine boron trifluoride (PBF) was added to these electrolytes, cell performance was dramatically improved. Replacing LiPF 6 by LiBF 4 in the electrolytes above, with or without PBF, yielded positive electrode symmetric cells with good capacity retention. Two types of surface coatings were explored on NMC622 positive electrodes. Cells using surface-coated positive electrodes demonstrated better capacity retention for all electrolytes compared to cells without surface coatings. Finally, this work can be used as a guide by those attempting to find electrolyte/electrode pairs suitable for use in NMC/graphite cells that can operate with long lifetime to 4.5 V.

25 ENERGY STORAGE↗

Electrolyte solutions including a phosphoranimine compound, and energy storage devices including same

An electrolyte solution comprising at least one phosphoranimine compound and a metal salt. The at least one phosphoranimine compound comprises a compound of the chemical structure ##STR00001## where X is an organosilyl group or a tert-butyl group and each of R.sup.1, R.sup.2, and R.sup.3 is independently selected from the group consisting of an alkyl group, an aryl group, an alkoxy group, or an aryloxy group. An energy storage device including the electrolyte solution is also disclosed.

25 ENERGY STORAGE↗

Synergistic Effect of LiPF 6 and LiBF 4 as Electrolyte Salts in Lithium-Ion Cells

Recent work shows promise for LiBF 4 as an electrolyte salt for high voltage lithium-ion batteries. LiBF 4 is more hydrolytically stable than LiPF 6 , and in some cases has proved to be more stable at high voltage. This work shows that 1.0 M electrolytes consisting of equal parts LiBF 4 and LiPF 6 have better performance in certain high voltage (4.35 V) lithium-ion cells than electrolytes with LiPF 6 or LiBF 4 alone. This is shown using long-term cycling and ultra-high precision coulometry on lithium-ion cells, with and without electrolyte additives. Ultra-high precision coulometry showed that electrolyte with 1:1 LiPF 6 :LiBF 4 and no other additives performed as well as electrolyte with LiPF 6 and state-of-the-art additive blends in these cells. The synergism between LiPF 6 and LiBF 4 was explored using XPS, symmetric cells and EIS analysis. These show that LiBF 4 reduces impedance growth at the positive electrode, while LiPF 6 improves passivation at the negative electrode.

25 ENERGY STORAGE↗

Method, system, and computer-readable medium for determining performance characteristics of an object undergoing one or more arbitrary aging conditions

A method, system, and computer-readable medium are described for characterizing performance loss of an object undergoing an arbitrary aging condition. Baseline aging data may be collected from the object for at least one known baseline aging condition over time, determining baseline multiple sigmoid model parameters from the baseline data, and performance loss of the object may be determined over time through multiple sigmoid model parameters associated with the object undergoing the arbitrary aging condition using a differential deviation-from-baseline approach from the baseline multiple sigmoid model parameters. The system may include an object, monitoring hardware configured to sample performance characteristics of the object, and a processor coupled to the monitoring hardware. The processor is configured to determine performance loss for the arbitrary aging condition from a comparison of the performance characteristics of the object deviating from baseline performance characteristics associated with a baseline aging condition.

97 MATHEMATICS AND COMPUTING↗

Methods, apparatuses, and computer-readable media for projectional morphological analysis of N-dimensional signals

Embodiments discussed herein in the form of methods, systems, and computer-readable media deal with the application of advanced "projectional" morphological algorithms for solving a broad range of problems. In a method of performing projectional morphological analysis, an N-dimensional input signal is supplied. At least one N-dimensional form indicative of at least one feature in the N-dimensional input signal is identified. The N-dimensional input signal is filtered relative to the at least one N-dimensional form and an N-dimensional output signal is generated indicating results of the filtering at least as differences in the N-dimensional input signal relative to the at least one N-dimensional form.

97 MATHEMATICS AND COMPUTING↗