Non-nulling seven-hole probes for high angle flow measurement

This paper illustrates a method for calibrating seven-hole probes to measure local total and static pressures and relative flow angles of up to 70 degrees in subsonic compressible flows. The method of Latin Squares was used to statistically sample a large and otherwise unmanageable data set, thereby reducing to a minimum the number of data points required to construct a polynomial curve fit to the data. Calibration produces three-variable third order polynomials which permit all of the desired flow properties to be found explicitly from probe measured pressures. This method determines the flow angles to within 2 degrees and Mach number to within 0.04 with 95 percent certainty.

Gerner, A. A.↗

Theory and calibration of non-nulling seven-hole cone probes for use in complex flow measurement

A seven-hole conical pressure probe capable of measuring flow conditions at angles up to 75 deg relative to its axis is described. The theoretical rationale of the seven-hole probe is developed and the calibration procedure outlined. Three-variable third order polynomials are used to represent local values of total pressure, static pressure, Mach number and relative flow angles. These flow conditions can be determined explicitly from measured probe pressures. Flow angles may be determined within 2.5 deg and Mach number within 0.05 with 95% certainty. The probe was calibrated in subsonic compressible and incompressible flows. Results of a calibration of four seven-hole probes are presented.