Search NASA⌕ Search

Engineering topics

Getty, Stephanie A.

Publications and source records attributed to Getty, Stephanie A..

21 records · Page 2

Effect of Nitrogen Gas on the Lifetime of Carbon Nanotube Field Emitters for Electron-Impact Ionization Mass Spectrometry

The lifetime of a patterned carbon nanotube film is evaluated for use as the cold cathode field emission ionization source of a miniaturized mass spectrometer. Emitted current is measured as a function of time for varying partial pressures of nitrogen gas to explore the robustness and lifetime of carbon nanotube cathodes near the expected operational voltages (70-100 eV) for efficient ionization in mass spectrometry. As expected, cathode lifetime scales inversely with partial pressure of nitrogen. Results are presented within the context of previous carbon nanotube investigations, and implications for planetary science mass spectrometry applications are discussed.

Getty, Stephanie A.↗

Simulation of a Miniature, Low-Power Time-of-Flight Mass Spectrometer for In Situ Analysis of Planetary Atmospheres

We are implementing nano- and micro-technologies to develop a miniaturized electron impact ionization mass spectrometer for planetary science. Microfabrication technology is used to fabricate the ion and electron optics, and a carbon nanotube (CNT) cathode is used to generate the ionizing electron beam. Future NASA planetary science missions demand miniaturized, low power mass spectrometers that exhibit high resolution and sensitivity to search for evidence of past and present habitability on the surface and in the atmosphere of priority targets such as Mars, Titan, Enceladus, Venus, Europa, and short-period comets. Toward this objective, we are developing a miniature, high resolution reflectron time-of-flight mass spectrometer (Mini TOF-MS) that features a low-power CNT field emission electron impact ionization source and microfabricated ion optics and reflectron mass analyzer in a parallel-plate geometry that is scalable. Charged particle electrodynamic modeling (SIMION 8.0.4) is employed to guide the iterative design of electron and ion optic components and to characterize the overall performance of the Mini TOF-MS device via simulation. Miniature (less than 1000 cubic centimeters) TOF-MS designs (ion source, mass analyzer, detector only) demonstrate simulated mass resolutions greater than 600 at sensitivity levels on the order of 10(exp -3) cps/molecule N2/cc while consuming 1.3 W of power and are comparable to current spaceflight mass spectrometers. Higher performance designs have also been simulated and indicate mass resolutions approximately 1000, though at the expense of sensitivity and instrument volume.

King, Todd T.↗

Performance of a Carbon Nanotube Field Emission Electron Gun

A cold cathode field emission electron gun (e-gun) based on a patterned carbon nanotube (CNT) film has been fabricated for use in a miniaturized reflectron time-of-flight mass spectrometer (RTOF MS). Performance of the CNT e-gun has been evaluated. A traditional thermionic electron gun has also been fabricated and evaluated in parallel and its performance is used as a benchmark in the evaluation of our CNT e-gun. Implications for future improvements and integration into the RTOF MS are discussed.

Getty, Stephanie A.↗