Search NASA⌕ Search

Engineering topics

Gevorgyan, N.

Publications and source records attributed to Gevorgyan, N..

Photoproduction of the f 2 ( 1270 ) Meson Using the CLAS Detector

The quark structure of the f 2 ( 1270 ) meson has, for many years, been assumed to be a pure quark-antiquark (q$\bar{q}$) resonance with quantum numbers J PC = 2 ++ . Recently, it was proposed that the f 2 ( 1270 ) is a molecular state made from the attractive interaction of two ρ mesons. Such a state would be expected to decay strongly to final states with charged pions due to the dominant decay ρ → π + π - , whereas decay to two neutral pions would likely be suppressed. Here, we measure for the first time the reaction γp → π 0 π 0 p , using the CEBAF Large Acceptance Spectrometer detector at Jefferson Lab for incident beam energies between 3.6 and 5.4 GeV. Differential cross sections, dσ/dt , for f 2 ( 1270 ) photoproduction are extracted with good precision due to low backgrounds and are compared to theoretical calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurement of direct photoproduction of the a 2 (1320) 0 meson on the proton

We present the first measurement of the reaction γ p → a 2 ( 1320 ) 0 p in the photon energy range 3.5– 5.5 Ge V and four-momentum transfer squared 0.2 < - t < 2.0 Ge V 2 . Data were collected with the CEBAF Large Acceptance Spectrometer detector at the Thomas Jefferson National Accelerator Facility. The a 2 resonance was detected by measuring the reaction γ p → π 0 η p and reconstructing the π 0 η invariant mass. The most prominent feature of the differential cross section is a dip at -t ≈ 0.55 Ge V 2 . This can be described in the framework of Regge phenomenology, where the exchange degeneracy hypothesis predicts a zero in the reaction amplitude for this value of the four-momentum transfer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗