Search NASA⌕ Search

Engineering topics

Gibbs, Kenneth M.

Publications and source records attributed to Gibbs, Kenneth M..

Process for the Recovery of Actinide and Lanthanide Oxides via Thermal Decomposition and Calcination of Loaded Diglycolamide Resin

Diglycolamide (DGA) resin, a product produced by Eichrom Technologies, Inc. employs TODGA (N,N,N',N'-tetraoctyldiglycolamide) as the active extractant, which will be used by Savannah River National Laboratory to extract trivalent actinides and lanthanides from dissolved irradiated Mark-18A targets. The final form of the extracted material will be an oxide suitable for shipment. A two-step process was developed and validated for the direct recovery of actinides and lanthanides loaded on I-grade DGA resin as nitrates by thermally drying and decomposing resin loaded with Nd(III), a surrogate for trivalent actinides and lanthanides, under inert conditions followed by calcining the resultant residue in air to provide an oxide product. Further, a stepwise heating profile up to 385°C under argon gas flow resulted in 85% to 89% mass loss during the resin drying and decomposition step, and calcination of the resultant Nd-loaded resin residue provided an overall material mass loss of ≥ 98%. Recoveries from resin saturated with Nd(III) from 7 M and 0.35 M nitric acid subjected to this process were 30.7 mg and 27.6 mg Nd/g dry resin, respectively, representing an average of 96.1% of Nd retained in the resin bed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

System and method for detecting high-energy photons

A system for detecting high-energy photons includes a pixelated image detector exposed to visible light and high-energy photons, and the pixelated image detector generates one or more images from the exposure to the visible light and high-energy photons. The system further includes one or more processors operably connected to the pixelated image detector and configured to perform operations on the one or more images to discriminate between visible light and high-energy photons. A method for detecting high-energy photons includes exposing a pixelated image detector to visible light and high-energy photons and discriminating between the visible light that interacts with the pixelated image detector and the high-energy photons that interact with the pixelated image detector.

Gibbs, Kenneth M.↗

Concealed identification symbols and nondestructive determination of the identification symbols

The concealing of one or more identification symbols into a target object and the subsequent determination or reading of such symbols through non-destructive testing is described. The symbols can be concealed in a manner so that they are not visible to the human eye and/or cannot be readily revealed to the human eye without damage or destruction of the target object. The identification symbols can be determined after concealment by e.g., the compilation of multiple X-ray images. As such, the present invention can also provide e.g., a deterrent to theft and the recovery of lost or stolen objects.

99 GENERAL AND MISCELLANEOUS↗

Digital X-ray Pipe Inspector Software

The Digital X-ray Pipe Inspector software requires a digital x-ray image of a pipe as input to the program, such as the image in Attachment A Figure 1. The image may be in a variety of software formats such as bitmap, jpeg, tiff, DICOM or DICONDE. The software allows the user to interactively select a region of interest from the image for analysis. This software is used to analyze digital x-ray images of pipes to evaluate loss of wall thickness. The software specifically provides tools to analyze the image in (a) the pipe walls, (b) between the pipe walls. Traditional software uses only the information at the pipe wall while this new software also evaluates the image between the pipewalls. This makes the inspection process faster, more thorough, more efficient, and reduces expensive reshots. Attachment A Figure 2 shows a region of interest (a green box) drawn by the user around an anomaly in the pipe wall. This area is automatically analyzed by the external pipe wall tool with the result shown in Attachment A Figure 3. The edges of the pipe wall are detected and highlighted in yellow and areas where the wall thickness in less the the minimum wall threshold are shown in red. These measurements are typically made manually in other software programs, which lead to errors and inconsistency because the location of the edges are estimated by the user. Attachment A Figure 4 shows a region of interest (a green box) drawn by the user between the pipe walls. As can be seen there are intensity anomalies that correspond to wall defects. However, this information is not used directly by other software programs. In order to fully investigate these anomalies, the pipe would be reinspected in a different orientation to attempt to obtain a view of the anomaly in the pipe wall rather than the interior of the pipe. The pipe may need to be x-rayed a number of times to obtain the correct orientation. This is very costly and time consuming. The new software can perform the analysis directly on the intensity information in the original image. Figures 5 through 9 in Attachment A show wall defects in red for various percents of wall thickness loss. For example, Figure 5 show defects (in red) where the wall thickness is 95% or less than the nominal wall thickness (or a 5% or greater wall thickness loss). Wall thicknesses can be given in absolute terms as well.

Gibbs, Kenneth M.↗