Methods of supporting a graphene sheet disposed on a frame support

This disclosure provides systems, methods, and apparatus related to graphene. In one aspect, a method includes submerging a frame support in an etching solution that is contained in a container. A growth substrate, a graphene sheet disposed on the growth substrate, and a primary support disposed on the graphene sheet is placed on a surface of the etching solution. The growth substrate is dissolved in the etching solution to leave the graphene sheet and the primary support floating on a surface of the etching solution. The etching solution in the container is replaced with a washing solution. The washing solution is removed from the container so that the graphene sheet becomes disposed on the frame support.

Han, Bong-Gyoon↗

Perspective: Biochemical and Physical Constraints Associated With Preparing Thin Specimens for Single-Particle Cryo-EM

While many aspects of single-particle electron cryo-microscopy (cryo-EM) of biological macromolecules have reached a sophisticated level of development, this is not yet the case when it comes to preparing thin samples on specimen grids. As a result, there currently is considerable interest in achieving better control of both the sample thickness and the amount of area that is useful, but this is only one aspect in which improvement is needed. This Perspective addresses the further need to prevent the macromolecular particles from making contact with the air-water interface, something that can result in preferential orientation and even structural disruption of macromolecular particles. This unwanted contact can occur either as the result of free diffusion of particles during the interval between application, thinning and vitrification of the remaining buffer, or—when particles have been immobilized—by the film of buffer becoming too thin prior to vitrification. An opportunity now exists to apply theoretical and practical insights from the fields of thin-film physical chemistry and interfacial science, in an effort to bring cryo-EM sample preparation to a level of sophistication that is comparable to that of current data collection and analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Minimizing Crinkling of Soft Specimens Using Holey Gold Films on Molybdenum Grids for Cryogenic Electron Microscopy

We introduce a novel composite holey gold support that prevents cryo-crinkling and reduces beam-induced motion of soft specimens, building on the previously introduced all-gold support. The composite holey gold support for high-resolution cryogenic electron microscopy of soft crystalline membranes was fabricated in two steps. In the first step, a holey gold film was transferred on top of a molybdenum grid. In the second step, a continuous thin carbon film was transferred onto the holey gold film. This support (Au/Mo grid) was used to image crystalline synthetic polymer membranes. The low thermal expansion of Mo is not only expected to avoid cryo-crinkling of the membrane when the grids are cooled to cryogenic temperatures, but it may also act to reduce whatever crinkling existed even before cooling. Here, the Au/Mo grid exhibits excellent performance with specimens tilted to 45°. This is demonstrated by quantifying beam-induced motion and differences in local defocus values. In addition, images of specimens on the Au/Mo grids that are tilted at 45° show high-resolution information of the crystalline membranes that, after lattice-unbending, extends beyond 1.5 Å in the direction perpendicular to the tilt axis.

36 MATERIALS SCIENCE↗

Stable support films for electron microscopy

This disclosure provides systems, methods, and apparatus related to arrangements including electron microscopy grids. In one aspect an arrangement includes an electron microscopy grid. The electron microscopy grid comprises a first surface and a second surface, with the first surface having a holey carbon film disposed thereon. A plurality of lipid molecules are disposed in a hole in the holey carbon film. Each lipid molecule of the plurality of lipid molecules has a hydrophilic head and a hydrophobic tail. A biotin-binding protein is attached to the hydrophilic heads of the plurality of lipid molecules. The biotin-binding protein is crystalline.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical-cavity based ponderomotive phase plate for transmission electron microscopy

An optical cavity is defined by a first mirror and a second mirror. The first mirror has a front surface that includes a first concave mirror. The second mirror has a front surface that includes a second concave mirror. The optical cavity has a resonant optical mode with a small focal spot size. The optical cavity may be used in a method of enhancing phase contrast in an electron beam image, and associated system for electron beam imaging or electron-beam spectroscopy, with a transmission electron beam microscope.

Axelrod, Jeremy J.↗

Methods and apparatus for preparing aqueous specimens for electron microscopy using volatile surfactants

This disclosure provides systems, methods, and apparatus related to the preparation of electron microscopy specimens. In one aspect, a method includes providing an electron microscopy grid. An aqueous suspension including an electron microscopy sample is deposited on the electron microscopy grid. A portion of the aqueous suspension is removed from the electron microscopy grid. A volatile surfactant is contacted to the aqueous suspension. A thickness of aqueous suspension is allowed to decrease over a period of time. The aqueous suspension is then frozen.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-pass transmission electron microscopy

Feynman once asked physicists to build better electron microscopes to be able to watch biology at work. While electron microscopes can now provide atomic resolution, electron beam induced specimen damage precludes high resolution imaging of sensitive materials, such as single proteins or polymers. Here, we use simulations to show that an electron microscope based on a multi-pass measurement protocol enables imaging of single proteins, without averaging structures over multiple images. While we demonstrate the method for particular imaging targets, the approach is broadly applicable and is expected to improve resolution and sensitivity for a range of electron microscopy imaging modalities, including, for example, scanning and spectroscopic techniques. The approach implements a quantum mechanically optimal strategy which under idealized conditions can be considered interaction-free.

47 OTHER INSTRUMENTATION↗

Monolayer-crystal streptavidin support films provide an internal standard of cryo-EM image quality

Analysis of images of biotinylated Escherichia coli 70S ribosome particles, bound to streptavidin affinity grids, demonstrates that the image-quality of particles can be predicted by the image-quality of the monolayer crystalline support film. Also, the quality of the Thon rings is a good predictor of the image-quality of particles, but only when images of the streptavidin crystals extend to relatively high resolution. When the estimated resolution of streptavidin was 5 Å or worse, for example, the ribosomal density map obtained from 22,697 particles went to only 9.5 Å, while the resolution of the map reached 4.0 Å for the same number of particles, when the estimated resolution of streptavidin crystal was 4 Å or better. It thus is easy to tell which images in a data set ought to be retained for further work, based on the highest resolution seen for Bragg peaks in the computed Fourier transforms of the streptavidin component. The refined density map obtained from 57,826 particles obtained in this way extended to 3.6 Å, a marked improvement over the value of 3.9 Å obtained previously from a subset of 52,433 particles obtained from the same initial data set of 101,213 particles after 3-D classification. These results are consistent with the hypothesis that interaction with the air-water interface can damage particles when the sample becomes too thin. Finally, streptavidin monolayer crystals appear to provide a good indication of when that is the case.

59 BASIC BIOLOGICAL SCIENCES↗

Long shelf-life streptavidin support-films suitable for electron microscopy of biological macromolecules

We describe a rapid and convenient method of growing streptavidin (SA) monolayer crystals directly on holey-carbon EM grids. As expected, these SA monolayer crystals retain their biotin-binding function and crystalline order through a cycle of embedding in trehalose and, later, its removal. This fact allows one to prepare, and store for later use, EM grids on which SA monolayer crystals serve as an affinity substrate for preparing specimens of biological macromolecules. In addition, we report that coating the lipid-tail side of trehalose-embedded monolayer crystals with evaporated carbon appears to improve the consistency with which well-ordered, single crystals are observed to span over entire, 2 μm holes of the support films. Randomly biotinylated 70S ribosomes are used as a test specimen to show that these support films can be used to obtain a high-resolution cryo-EM structure

59 BASIC BIOLOGICAL SCIENCES↗

Protein complexes in focus

A new advance in electron microscopy can reveal highly-detailed structures of protein complexes.

59 BASIC BIOLOGICAL SCIENCES↗

How good can cryo-EM become?

The suddenness with which single-particle cryo-electron microscopy (cryo-EM) has emerged as a method for determining high-resolution structures of biological macromolecules invites the questions, how much better can this technology get, and how fast is that likely to happen? While we can rightly celebrate the maturation of cryo-EM as a high-resolution structure-determination tool, I believe there still are many developments to look forward to.

59 BASIC BIOLOGICAL SCIENCES↗

Factors that Influence the Formation and Stability of Thin, Cryo-EM Specimens

Poor consistency of the ice thickness from one area of a cryo-electron microscope (cryo-EM) specimen grid to another, from one grid to the next, and from one type of specimen to another, motivates a reconsideration of how to best prepare suitably thin specimens. We first review the three related topics of wetting, thinning, and stability against dewetting of aqueous films spread over a hydrophilic substrate. Furthermore, we then suggest that the importance of there being a surfactant monolayer at the air-water interface of thin, cryo-EM specimens has been largely underappreciated. In fact, a surfactant layer (of uncontrolled composition and surface pressure) can hardly be avoided during standard cryo-EM specimen preparation. Thus it is suggested that better control over the composition and properties of the surfactant layer may result in more reliable production of cryo-EM specimens with the desired thickness.

59 BASIC BIOLOGICAL SCIENCES↗

Invited Review Article: Methods for imaging weak-phase objects in electron microscopy

Contrast has traditionally been produced in electron-microscopy of weak phase objects by simply defocusing the objective lens. There now is renewed interest, however, in using devices that apply a uniform quarter-wave phase shift to the scattered electrons relative to the unscattered beam, or that generate in-focus image contrast in some other way. Renewed activity in making an electron-optical equivalent of the familiar “phase-contrast” light microscope is based in part on the improved possibilities that are now available for device microfabrication. There is also a better understanding that it is important to take full advantage of contrast that can be had at low spatial frequency when imaging large, macromolecular objects. In addition, a number of conceptually new phase-plate designs have been proposed, thus increasing the number of options that are available for development. The advantages, disadvantages, and current status of each of these options is now compared and contrasted. Experimental results that are, indeed, superior to what can be accomplished with defocus-based phase contrast have been obtained recently with two different designs of phase-contrast aperture. Nevertheless, extensive work also has shown that fabrication of such devices is inconsistent, and that their working lifetime is short. The main limitation, in fact, appears to be electrostatic charging of any device that is placed into the electron diffraction pattern. The challenge in fabricating phase plates that are practical to use for routine work in electron microscopy thus may be more in the area of materials science than in the area of electron optics.

36 MATERIALS SCIENCE↗

Electron microscope phase enhancement

A microfabricated electron phase shift element is used for modifying the phase characteristics of an electron beam passing though its center aperture, while not affecting the more divergent portion of an incident beam to selectively provide a ninety-degree phase shift to the unscattered beam in the back focal plan of the objective lens, in order to realize Zernike-type, in-focus phase contrast in an electron microscope. One application of the element is to increase the contrast of an electron microscope for viewing weakly scattering samples while in focus. Typical weakly scattering samples include biological samples such as macromolecules, or perhaps cells. Preliminary experimental images demonstrate that these devices do apply a ninety degree phase shift as expected. Electrostatic calculations have been used to determine that fringing fields in the region of the scattered electron beams will cause a negligible phase shift as long as the ratio of electrode length to the transverse feature-size aperture is about 5:1. Calculations are underway to determine the feasibility of aspect smaller aspect ratios of about 3:1 and about 2:1.

47 OTHER INSTRUMENTATION↗