Progress on Advancing the Robotic Air-slot Volumetric Inspection System (RAVIS) for Hanford Under-tank Inspection - 20519

The 27 in-service double-shell tank (DST) systems at Hanford provide interim storage for nearly 56 million gallons of nuclear and hazardous chemical legacy waste. The safe and reliable storage of the waste is critical to the site's extended cleanup mission. While in service, the leak integrity of the DSTs must be demonstrated to satisfy the Washington Administrative Code, inform decisions on tank management, and gauge fitness for continued service beyond originally intended design lives. The carbon steel plates and welds that comprise DST primary tank sidewalls and lower knuckles are routinely 'sampled' for volumetric non-destructive testing using ultrasonic inspection technology to determine whether corrosion pitting, cracking, or general corrosion are occurring that could compromise tank leak integrity. However, the carbon steel plates and welds that comprise the bottoms of primary tanks have not been thoroughly inspected since the DSTs were constructed (i.e., since 1968-1986) due to limited physical access to the exterior tank bottoms. The Robotic Air-slot Volumetric Inspection System, or 'RAVIS,' is being engineered to overcome the challenge of tank bottom in-service inspection. The system will be deployed under primary tanks within the small cooling channels/air-slots in the refractory pads upon which the tanks rest and will use ultrasonic guided wave inspection technology to volumetrically inspect physically inaccessible regions that make up ∼90% of a tank bottom, as well as regions that are physically accessible from the air-slots but comprise only ∼10% of a tank bottom. This paper describes the air-slot sensor and robotic deployment system and focuses on the testing approach and methods that are being applied to support (1) design feedback and performance acceptance (requirement verification) and (2) performance repeatability/reliability assessments (qualification) to ensure the RAVIS is prepared for successful inservice inspections of primary tank bottoms. Test progress made against the test plan, the results of 2019 testing, and the future outlook are included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress Toward Molten Salt Reactor Heat Exchanger On-Line Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Assessment of EPRI’s Tan Delta Approach to Manage Cables in Submerged Environments: Statistical Review of EPRI Data

Research conducted by the Electric Power Research Institute (EPRI) and other research institutions have concluded that water-trees are one of the leading degradation mechanisms that contribute to the loss of dielectric insulation strength in medium-voltage cable insulating materials in wet or submerged environments. The electrochemical reactions are caused by the combined effect of water presence and relatively high electrical stress. Records of cable failures provided by the licensees in response to Generic Letter (GL) 2007-01 (NRC 2007) have called into question the reliability of medium voltage cables in wetted or submerged environments. EPRI’s dissipation factor or Tan Delta testing guidelines and acceptance criteria have been adopted by most nuclear power plant operators as the primary tool for condition monitoring of medium voltage cables in wet or submerged environments. EPRI has been collecting member data since late 2009 to analyze and provide feedback to members, validate the EPRI-developed acceptance criteria guidelines, support analysis of test results, recommend appropriate actions for the "action required" category, and gather candidate cables for EPRI-sponsored forensic research on causes for insulation degradation. EPRI has collected data from 37 nuclear sites, which represent 44 operating units. The test results have been organized by insulation type, such as cross-linked polyethylene (XLPE); butyl rubber; black, pink, and brown ethylene-propylene rubber (EPR); and compact insulation (black and pink EPR)1. The data have been analyzed, and follow-up information was obtained from members for “action required” test results. EPRI has also performed correlations between Tan Delta tests and the information gathered under the EPRI forensic research on medium-voltage cables. In addition, EPRI has developed guidance by cable insulation type on how to systematically analyze Tan Delta test results. The analysis described here reviewed the two primary EPRI reports (EPRI 3002000557 and EPRI 3002005321) as well as two precedent EPRI reports (EPRI 1028262 and EPRI 1021070) that were cited in the primary reports. The principal results and conclusions from the project analyses are provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation and Experimental Results of Interdigital Capacitor (IDC) Sensors to Monitor Insulation Degradation of Cables

The efficacy of using interdigital capacitor (IDC) sensors to monitor cable insulation aging was studied through electromagnetic simulations and experimental measurements. Simulation results on both planar and conformal dielectric materials indicated that IDCs on thin substrates and with conducting backplanes provide superior performance in terms of higher capacitance. An airgap study showed that even a very small airgap between the sensor and the cable’s insulation results in significant reduction in capacitance; therefore, airgaps should be minimized. Finally, cables that underwent accelerated aging exposure in an oven were tested using fabricated IDC sensors. Measurement results showed a 12.5% increase in capacitance when the IDC was pressed against the insulation versus a 91.3% increase in capacitance when the IDC was pressed against the jackets of the cables for cable specimens ranging from unaged to aged 35 days.

Cable NDE, Interdigital Capacitance↗