A cooled-gas pyrometer for use in high-temperature gas streams
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Glawe, George E.
Explore the source record for details and available documents.
A Nusselt-Reynolds number relation for cylindrical thermocouple wires in crossflow was obtained from the experimental determination of time constants. Tests were conducted in exhaust gas over a temperature range of 2000 to 3400 R, a Mach number range of 0.3 to 0.8, and a static-pressure range from 2/3 to 1-1/3 atmospheres, yielding a Reynolds number range of 450 to 3000. The correlation obtained is Nu=(0.428 plus or minus 0.003) times the square root of Re* with average deviations of a single observation of 8.5 percent. This relation is the same as one previously reported for room-temperature conditions.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Thermocouples were exposed to exhaust gases from the combustion of propane, 72-octane gasoline, and JP-4 fuel. Exposure increased the emissivity of the thermocouple wire, which increased its radiation error. Two methods are presented for determining the emittance of the wires. The emissivity of a clean platinum rhodium-platinum thermocouple was approximately 0.2 in the temperature range investigated, while the emittance of an exposed thermocouple coated with exhaust residue was about 0.5. The exposure caused negligible change in the thermoelectric power of the thermocouples.