Implementation of a Pulsed-Laser Measurement System in the National Transonic Facility

A remotely-adjustable laser transmission and imaging system has been developed for use in a high-pressure, cryogenic wind tunnel. Implementation in the National Transonic Facility has proven the system suitable for velocity and signal lifetime measurements over a range of operating conditions. The measurement system allows for the delivery of high-powered laser pulses through the outer pressure shell and into the test section interior from a mezzanine where the laser is free from environmental disturbances (such as vibrations and excessive condensation) associated with operation of the wind tunnel. Femtosecond laser electronic excitation tagging (FLEET) was utilized to provide freestream velocity measurements, and first results show typical data that may be obtained using the system herein described.

Reese, Daniel T.↗

Feasibility of Rayleigh Scattering Flow Diagnostics in the National Transonic Facility

Laser-based Rayleigh light scattering (RLS) was performed in the National Transonic Facility (NTF) at NASA Langley Research Center. The goal was to determine if the free-stream flow undergoes clustering (early stage of condensation from gas to liquid) or remains in a pure diatomic molecular phase. Data indicate that clusters are not observable down to levels of 10% of the total light scatter for a variety of total pressures at one N2 cryogenic-mode total temperature (Tt = -50 F = 227 K) and one air-mode temperature (Tt = +130 F = 327 K). Thus RLS appears viable as a qualitative or quantitative diagnostic for flow density in NTF in the future. Particles are distinguished from optically unresolvable clusters because they are much larger and individually resolvable in the laser beam image with Mie scattering. The same RLS apparatus was also used, without modification, to visualize naturally occurring particles entrained in the flow for both cryogenic and air-modes. Estimates of the free-stream particle flux are presented, which may be important for interpretation of laminar-to-turbulent boundary-layer transition studies. 1

Herring, Gregory C.↗

Measuring Global Surface Pressures on a Circulation Control Concept Using Pressure Sensitive Paint

This report will present the results obtained from the Pressure Sensitive Paint (PSP) technique on a circulation control concept model. This test was conducted at the National Transonic Facility (NTF) at the NASA Langley Research Center. PSP was collected on the upper wing surface while the facility was operating in cryogenic mode at 227 K (-50 oF). The test envelope for the PSP portion included Mach numbers from 0.7 to 0.8 with angle of attack varying between 0 and 8 degrees and a total pressure of approximately 168 kPa (24.4 psi), resulting in a chord Reynolds number of approximately 15 million. While the PSP results did exhibit high levels of noise in certain conditions (where the oxygen content of the flow was very small), some conditions provided good correlation between the PSP and pressure taps, showing the ability of the PSP technique. This work also served as a risk reduction opportunity for future testing in cryogenic conditions at the NTF.

Watkins, Anthony N.↗

Results From a Pressure Sensitive Paint Test Conducted at the National Transonic Facility on Test 197: The Common Research Model

This report will serve to present results of a test of the pressure sensitive paint (PSP) technique on the Common Research Model (CRM). This test was conducted at the National Transonic Facility (NTF) at NASA Langley Research Center. PSP data was collected on several surfaces with the tunnel operating in both cryogenic mode and standard air mode. This report will also outline lessons learned from the test as well as possible approaches to challenges faced in the test that can be applied to later entries.

Watkins, A. Neal↗

The Development and Implementation of a Cryogenic Pressure Sensitive Paint System in the National Transonic Facility

The Pressure Sensitive Paint (PSP) method was used to measure global surface pressures on a model at full-scale flight Reynolds numbers. In order to achieve these conditions, the test was carried out at the National Transonic Facility (NTF) operating under cryogenic conditions in a nitrogen environment. The upper surface of a wing on a full-span 0.027 scale commercial transport was painted with a porous PSP formulation and tested at 120K. Data was acquired at Mach 0.8 with a total pressure of 200 kPa, resulting in a Reynolds number of 65 x 106/m. Oxygen, which is required for PSP operation, was injected using dry air so that the oxygen concentration in the flow was approximately 1535 ppm. Results show qualitative agreement with expected results. This preliminary test is the first time that PSP has been successfully deployed to measure global surface pressures at cryogenic condition in the NTF. This paper will describe the system as installed, the results obtained from the test, as well as proposed upgrades and future tests.

Watkins, A. Neal↗

Data-Acquisition Software for PSP/TSP Wind-Tunnel Cameras

Wing-Viewer is a computer program for acquisition and reduction of image data acquired by any of five different scientificgrade commercial electronic cameras used at Langley Research center to observe wind-tunnel models coated with pressure or temperature-sensitive paints (PSP/TSP). Wing-Viewer provides full automation of camera operation and acquisition of image data, and has limited data-preprocessing capability for quick viewing of the results of PSP/TSP test images. Wing- Viewer satisfies a requirement for a standard interface between all the cameras and a single personal computer: Written by use of Microsoft Visual C++ and the Microsoft Foundation Class Library as a framework, Wing-Viewer has the ability to communicate with the C/C++ software libraries that run on the controller circuit cards of all five cameras.

Amer, Tahani R.↗

Flow Visualization at Cryogenic Conditions Using a Modified Pressure Sensitive Paint Approach

A modification to the Pressure Sensitive Paint (PSP) method was used to visualize streamlines on a Blended Wing Body (BWB) model at full-scale flight Reynolds numbers. In order to achieve these conditions, the tests were carried out in the National Transonic Facility operating under cryogenic conditions in a nitrogen environment. Oxygen is required for conventional PSP measurements, and several tests have been successfully completed in nitrogen environments by injecting small amounts (typically < 3000 ppm) of oxygen into the flow. A similar technique was employed here, except that air was purged through pressure tap orifices already existent on the model surface, resulting in changes in the PSP wherever oxygen was present. The results agree quite well with predicted results obtained through computational fluid dynamics analysis (CFD), which show this to be a viable technique for visualizing flows without resorting to more invasive procedures such as oil flow or minitufts.

Watkins, A. Neal↗

Wing Twist Measurements at the National Transonic Facility

A technique for measuring wing twist currently in use at the National Transonic Facility is described. The technique is based upon a single camera photogrammetric determination of two dimensional coordinates with a fixed (and known) third dimensional coordinate. The wing twist is found from a conformal transformation between wind-on and wind-off 2-D coordinates in the plane of rotation. The advantages and limitations of the technique as well as the rationale for selection of this particular technique are discussed. Examples are presented to illustrate run-to-run and test-to-test repeatability of the technique in air mode. Examples of wing twist in cryogenic nitrogen mode are also presented.

Burner, Alpheus W.↗

Digital Video Measurements Of Wing Deflections In A Wind Tunnel

Solid-state cameras and computer-controlled image-acquisition system measure deformations of wind-tunnel models. Digital video model-deformation (VMD) system includes solid-state-array cameras and digital image-acquisition system controlled by personal computer. Eliminates both vibration-induced distortion associated with tube cameras and manual processing of video hardcopy images necessary in earlier version. AT-class personal computer controls two commercially available image-capture boards ganged to capture simultaneously two video images, each 752 picture elements wide and 480 picture elements high, in one-thirtieth of second. Video images digitized into 256 gray levels. Figure block diagram of system.

Burner, Alpheus W.↗

Photogrammetric technique for in-flight ranging of trailing vortices using entrained balloons

A method for experimentally determining the radial distance of a probe aircraft from a trailing vortex is described. The method relies on photogrammetric triangulation of targets entrained in the vortex core. The theory and preliminary testing were described using laboratory mock-ups. Solid state video cameras were to provide data at 300 Hz rates. Practical methods for seeding the vortex are under separate investigation and are not addressed.

Snow, Walter L.↗

Recent flow visualization studies in the 0.3-m TCT

Light beams are altered by refractive index changes; flow induced refractive index changes provide the impetus for conventional visualization techniques such as schlieren and shadowgraph. Unfortunately effects related to the flow can be masked by refractive index inhomogeneities external to the test section. A simple shadowgraph scheme was used to assess the flow quality of the Langley 0.3 meter Transonic Cryogenic Tunnel. When the penetration tubes were evacuated the quality of the shadowgraph improved dramatically.

Snow, Walter L.↗