Search NASA⌕ Search

Engineering topics

Goetz, Alexander F. H.

Publications and source records attributed to Goetz, Alexander F. H..

At least 37 records · Page 2

A linear spectral matching technique for retrieving equivalent water thickness and biochemical constituents of green vegetation

Over the last decade, technological advances in airborne imaging spectrometers, having spectral resolution comparable with laboratory spectrometers, have made it possible to estimate biochemical constituents of vegetation canopies. Wessman estimated lignin concentration from data acquired with NASA's Airborne Imaging Spectrometer (AIS) over Blackhawk Island in Wisconsin. A stepwise linear regression technique was used to determine the single spectral channel or channels in the AIS data that best correlated with measured lignin contents using chemical methods. The regression technique does not take advantage of the spectral shape of the lignin reflectance feature as a diagnostic tool nor the increased discrimination among other leaf components with overlapping spectral features. A nonlinear least squares spectral matching technique was recently reported for deriving both the equivalent water thicknesses of surface vegetation and the amounts of water vapor in the atmosphere from contiguous spectra measured with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). The same technique was applied to a laboratory reflectance spectrum of fresh, green leaves. The result demonstrates that the fresh leaf spectrum in the 1.0-2.5 microns region consists of spectral components of dry leaves and the spectral component of liquid water. A linear least squares spectral matching technique for retrieving equivalent water thickness and biochemical components of green vegetation is described.

Gao, Bo-Cai↗

Separation of cirrus cloud from clear surface from AVIRIS data using the 1.38 micron water vapor band

Cirrus clouds play an important role in climate systems because of their large area coverage, persistence, and radiative effects. Thin cirrus clouds are difficult to detect in visible images and infrared images in the 10-12 micron atmospheric window region, particularly over land, because these clouds are partially transparent. Ackerman recently developed a method for detecting cirrus clouds using three narrow channels centered near 8, 11, and 12 microns, respectively, based on the analysis of IR emission spectra measured with a high spectral resolution interferometer. Barton also described a method for estimating cirrus cloud height and amount from measurements with two narrow channel radiometers of the Selective Chopper Radiometer on Nimbus 5. Both channels are located within the strong 2.7 micron water vapor band absorption region. One of the channels includes additional carbon dioxide absorption. A differential absorption technique with sets of empirical coefficients was used in the estimation of cirrus cloud heights and amounts. A technique using narrow channels in the strong 1.38 micron water vapor band absorption region for detecting cirrus clouds from spectral imaging data acquired by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) on 5 Dec. 1991 during the FIRE (The First International Satellite Cloud Climatology Project (ISCCP) Regional Experiment) Phase 2 Field Experiment is described.

Gao, Bo-Cai↗

Software for the derivation of scaled surface reflectances from AVIRIS data

An operational software program is now available for deriving 'scaled surface reflectances' from spectral data collected by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). The program simulates both the atmospheric scattering and absorption effects. Brief descriptions of the algorithm, inputs, outputs, the limitations of the software, and procedures for obtaining the software are given.

Gao, Bo-Cai↗

Discrimination among semi-arid landscape endmembers using the Spectral Angle Mapper (SAM) algorithm

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data were acquired during three consecutive seasons of the year (26 Sep. 1989, 22 Mar. 1990, and 7 Aug. 1990) over an area of the High Plains east of Greeley, Colorado. This region contains extensive eolian deposits in the form of stabilized dune complexes (small scale parabolic dunes superimposed on large scale longitudinal and parabolic dunes). Due to the dunes' large scale (2-10 km) and low relief (1-5 m), the scaling relationships that contribute to the evolution of this landscape are nearly impossible to understand without the use of remote sensing. Additionally, climate models indicate that the High Plains could be one of the first areas to experience changes in climate caused by either global warming or cooling. During the past 10,000 years there were at least three periods of extensive sand activity, followed by periods of landscape stability, as shown in the stratigraphic record of this area. Therefore, if the past is an indication of the future, the monitoring of this landscape and its sensitive ecosystem is important for early detection of regional and global climate change.

Yuhas, Roberta H.↗

HIRIS, the instrument and its science

The High Resolution Imaging Spectrometer (HIRIS) is a facility instrument slated for flight on the second EOS series AM platforms. HIRIS is designed to acquire 24 km wide, 30 m pixel images in 192 spectral bands simultaneously in the 0.4-2.45 micron wavelength region. With pointing mirrors it can sample any place on Earth, except the poles, every 2 days. HIRIS operates at the intermediate scale between the human and the global and therefore links studies of Earth surface processes to global monitoring carried out by lower resolution instruments. So far, over 50 science data products from HIRIS images have been identified in the fields of atmospheric gases, clouds, snow and ice, water, vegetation, and rocks and soils. The key attribute of imaging spectrometry that makes it possible to derive quantitative information from the data is the large number of contiguous, spectral bands. Therefore, spectrum-matching techniques can be applied. Such techniques are not possible with present-day, multispectral scanner data.

Goetz, Alexander F. H.↗

Cloud area determination from AVIRIS data using water vapor channels near 1 micron

Fractional cloud area is derived from spectral images collected by the Airborne Visible-IR Imaging Spectrometer (AVIRIS). The derivation is made by ratioing radiances near the 0.94- and the 1.14-microns water vapor band centers against those in the intermediate atmospheric window regions. The derivation makes use of the facts that (1) the reflectances of most ground targets vary approximately linearly with wavelength in the 0.94- and the 1.14-micron water vapor band absorption regions, and (2) the peak absorptions of the water vapor band over cloudy areas are smaller than those over nearby clear surface areas because of the rapidly decreasing atmospheric water vapor concentration with height. The band ratioing technique effectively discriminates among clouds and surface areas having similar reflectance values.

Gao, Bo-Gai↗

Removing Atmospheric Effects From AVIRIS Data for Surface Reflectance Retrievals

Analysis of high resolution imaging spectrometer data requires a thorough compensation for atmospheric absorption and scattering. A method for retrieving surface reflectances from spectral data collected by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is being developed. In this method, the integrated water vapor amount on a pixel by pixel basis is derived from the 0.94- and 1.14-micrometer water vapor features. The water vapor, carbon dioxide (CO2), oxygen (O2) and methane (CH4) transmission spectrum in the 0.4-2.5 micrometer region is calculated. The derived water vapor value and the solar and observational geometry are used in the spectral calculation. The AVIRIS spectrum is ratioed against the transmission spectrum to obtain the surface reflectance spectrum. Major mineral absorption features near 2.2 micrometer in retrieved reflectance spectra can be identified. Different vegetation absorption characteristics are observed. At present, the method is most useful for deriving surface reflectances from AVIRIS data measured on clear days with high visibilities. Atmospheric scattering effects will be included in our spectral calculations in the near future.

Gao, Bo-Cai↗

Retrievals of surface reflectances from AVIRIS data

A method for retrieving surface reflectances from spectral data collected by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is being developed. In this method, the integrated water vapor amount on a pixel by pixel basis is derived from the 0.94- and 1.14-micron water vapor features. The water vapor, carbon dioxide (CO2), oxygen (O2) and methane (CH4) transmission spectrum in the 0.4-2.5 micron region is calculated. The derived water vapor value and the solar and observational geometry are used in the calculation. The AVIRIS spectrum is ratioed against the transmission spectrum to obtain the surface reflectance spectrum. Major mineral absorption features near 2.2 microns in retrieved reflectance spectra can be identified. Different vegetation absorption characteristics are observed. At present, the method is most useful for deriving surface reflectances from AVIRIS data measured on clear days with high visibilities.

Gao, Bo-Cai↗

Remote sensing of ferric iron minerals as guides for gold exploration

The relationship between the surficial iron mineralogy and economic mineralization is investigated, using data from an airborne imaging spectrometer (the 63-channel Geophysical and Environmental Research Imaging Spectrometer) to map the distribution of iron minerals in the Cripple Creek mining district in Colorado. The airborne image data were coregistered with the field map data for the distribution of iron oxides in the district, in a geographic information computer system, in order to compare their information content. It is shown that the remote imagery was able to uniquely identify the mineral hematite, a mixture of goethite/jarosite, and a mixture of hematite/goethite.

Taranik, Dan L.↗

High Resolution Imaging Spectrometer (HIRIS): Science and Instrument

The High Resolution Imaging Spectrometer (HIRIS) is a facility instrument slated for flight on the second of the EOS-A series of platforms. HIRIS is designed to acquire 24-km wide, 30-m pixel images in 192 spectral bands simultaneously in the 0.4-2.45-micrometer wavelength region. With pointing mirrors it can sample any place on Earth, except the poles, every two days. HIRIS operates at the intermediate scale between the human and the global and therefore links studies of Earth surface processes to global monitoring carried out by lower-resolution instruments. So far, over 50 science data products from HIRIS images have been identified in the fields of atmospheric gases, clouds, snow and ice, water, vegetation, and rocks and soils. The key attribute of imaging spectrometry that makes it possible to derive quantitative information from the data is the large number of contiguous spectral bands. Therefore spectrum matching techniques can be applied. Such techniques are not possible with present-day, multispectral scanner data.

Goetz, Alexander F. H.↗

Vegetation Biochemistry: What Can Imaging Spectrometry Tell Us About Canopies?

Changes in ecosystem processes such as productivity and decomposition may be expressed in the canopy foliar chemistry resulting from altered carbon allocation patterns, metabolic processes and nutrient availability. Understanding carbon balance on land over large regions requires quantitative determination of leaf constituents such as lignin and total nitrogen from remote sensing imaging systems. Results from spectral reflectance measurements of stacked leaves in the laboratory show that spectrum matching techniques are applicable to the derivation of the equivalent liquid water thickness in plants as well as to the extraction of dry leaf matter reflectance spectra from spectra of green leaves. The residual spectra derived by subtracting water spectra from the spectra of green leaves shows a feature at 1.72 micrometers that can be related to the lignin content of the leaves. Oak leaves have a deeper residual absorption feature than do cotton leaves which is consistent with their relative lignin content. Similar results are achieved when deriving the residuals from images taken over areas of grass and pine trees. Imaging spectrometry provides promise in developing images of various foliar biochemical constituents.

Goetz, Alexander F. H.↗

High-Resolution Imaging Spectrometer

Earth resources observed in greater detail. High-Resolution Imaging Spectrometer, undergoing development for use in NASA's Earth Observing System, measures reflectance of Earth's surface in visible and near-infrared wavelengths. From an orbit around Earth, instrument scans surface of Earth in 200 wavelength bands simultaneously. Produces images enabling identification of minerals in rocks and soils, important algal pigments in oceans and inland waters, changes in spectra associated with biochemistry of plant canopies, compositions of atmospheric aerosols, sizes of grains in snow, and contamination of snow by impurities that absorb visible light.

Dozier, Jeff↗

Terrestrial-Imaging Spectroscopy

Report reviews history and state of art of terrestrial imaging spectroscopy. Discusses history, design, and performance of Airborne Imaging Spectrometer (AIS), which is pioneering sensor for terrestrial high-resolution remote sensing. Also discusses recent developments described in literature of imaging spectroscopy from three points of view: techniques for handling and analysis of spectral-image data, geological research, and botanical research. This field encompasses use of airborne and spaceborne imaging spectrometers to generate specialized maps for use in agriculture, geology, ecology, and related disciplines.

Vane, Gregg A.↗

Sedimentary Facies Analysis Using AVIRIS Data: A Geophysical Inverse Problem

AVIRIS data can be used to quantitatively analyze and map sedimentary lithofacies. The observed radiance spectra can be reduced to 'apparent reflectance' spectra by topographic and reflectance characterization of several field sites within the image. These apparent reflectance spectra correspond to the true reflectance at each pixel, multiplied by an unknown illumination factor (ranging in value from zero to one). The spatial abundance patterns of spectrally defined lithofacies and the unknown illumination factors can be simultaneously derived using constrained linear spectral unmixing methods. Estimates of the minimum uncertainty in the final results (due to noise, instrument resolutions, degree of illumination and mixing systematics) can be made by forward and inverse modeling. Specific facies studies in the Rattlesnake Hills region of Wyoming illustrate the successful application of these methods.

Boardmann, Joe W.↗

The high resolution imaging spectrometer (HIRIS) for EOS

The high resolution imaging spectrometer (HIRIS) designed for the Earth Observing System (EOS) is designed to acquire images in 192 spectral bands simultaneously in the 0.4-2.5-micron wavelength region. HIRIS is a targeting rather than a continuous acquisition instrument and obtains high-spatial- and spectral-resolution images in a 30-km swath with a 30-m ground instantaneous field of view (GIFOV) in vertical viewing. Pointing will allow image acquisition at -30 to +60 deg along-track and +/-24 deg cross-track. The raw data rate of the instrument is 512 Mbs. The high spectral resolution will make it possible to identify many surficial materials such as rocks, soils, and suspended matter in water directly. HIRIS also offers the possibility of studying biochemical process in vegetation canopies.

Goetz, Alexander F. H.↗

Mineralogy and composition of Archean Crust, Greenland: A pilot study

The Portable Instant Display and Analysis Spectrometer (PIDAS) was taken to southwestern Greenland to investigate in situ the potential application of AVIRIS to estimate the mineralogy and composition of rocks exposed in Archean terranes. The goal was to determine the feasibility of using a high spectral resolution scanner to find and study pristine rocks, those that have not been altered by subsequent deformation and metamorphism. The application of AVIRIS data to the problems in Greenland is logical. However, before a costly deployment of the U-2 aircraft to Greenland is proposed, this study was undertaken to acquire the spectral data necessary to verify that mineralogical mapping in the environmental conditions found there is possible. Although field conditions were far from favorable, all of the major objectives of the study were addressed. One of the major concerns was that lichens would obscure the rock surfaces. It was found that the spectral signature of the lichens was distinct from the underlying rocks. Thus, a spectrum of a rock outcrop, with its partial cover of lichens, can be un-mixed into rock and lichen components. The data acquired during the course of this study supports the conclusion that areas of pristine Archean crust can be differentiated from that which has experienced low grade alteration associated with Proterizoic faulting.

Goetz, Alexander F. H.↗

Column atmospheric water vapor retrievals from airborne imaging spectrometer data

High-spatial-resolution column atmospheric water vapor amounts were derived from spectral data collected by the Airborne Visible Infrared Imaging Spectrometer (AVIRIS). The quantitative derivation is made by curve fitting observed spectra with calculated spectra in the 1.14- and 0.94-micron water-vapor band absorption regions with a nonlinear least-squares technique. The precision of the retrieved column water vapor is approximately 5 percent. The derived column water vapor amounts are independent of the absolute surface reflectance. Curve fitting of spectra near 1 micron from areas covered with vegetation indicates that both the amount of atmospheric water vapor and the moisture content of vegetation can be retrieved simultaneously. It should be possible to measure column water vapor over land areas from satellite altitude with the proposed high-resolution imaging spectrometer or even the moderate-resolution imaging spectrometer.

Gao, Bo-Cai↗

Terrestrial imaging spectroscopy

Recent advances in imaging spectroscopy for remote sensing applications are discussed, reviewing the results of recent investigations. The advantages offered by the higher spectral resolution of imaging spectroscopy relative to scanners such as Landsat MSS and TM are explained; the design and performance of the Airborne Imaging Spectrometer (Vane et al., 1984) are described and illustrated with drawings, photographs, and sample images; data processing and analysis techniques are outlined; and applications to geological and botanical research are considered.

Vane, Gregg↗