Search NASA⌕ Search

Engineering topics

Golovkin, I.

Publications and source records attributed to Golovkin, I..

At least 19 records

Establishing an isoelectronic line ratio temperature diagnostic for soft X-ray absorption spectroscopy

For diagnosing temperatures of high-energy-density plasmas, relying on the ratio of a pair of isoelectronic spectral lines provides the alternative of ‘‘matched charge-state transits in different elements’’ to the more conventional, ‘‘unmatched charge-state transits in the same-element’’ spectral-line-ratio technique. In contrast to a novel previous establishment of isoelectronic emission-line ratio determination of plasma temperature, this report determines plasma temperature from the ratio of isoelectronic absorption spectral line pairs. Here, the feasibility of this technique is assessed from experimentally acquired transmission spectra, spanning the 7– 15 Å range, through a 0.4 μm MgO-NaF foil, tamped with CH, x-ray-radiation heated by a z-pinch dynamic hohlraum (ZPDH), and backlit by the brief X-ray burst upon imploding-wire stagnation on the Z pulsed-power facility at Sandia National Laboratories. As expected from the slight difference between interstage and isoelectronic absorption processes, a quantitative comparison between the value of isoelectronic-absorption-derived temperature and the value of inter-stage-absorption-derived temperature is shown to yield a well correlated, slight difference in inferred values of plasma temperature associated with local thermodynamic equilibrium.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of non-thermal electron formation during the thermal quench of shattered pellet injection shutdowns in DIII-D

Formation of non-thermal (hot) electrons is studied during the thermal quench of shattered pellet injection (SPI) discharge shutdowns in the DIII-D tokamak. Both pure neon and mixed neon/deuterium shutdowns are studied. High-energy radiation (SXR and EUV) brightness levels show indications of non-thermal electron formation during the TQ. The non-thermal densities are of order 10 18 m –3 and non-thermal temperatures are estimated to be of order 10 keV. The non-thermal electrons appear to be mostly lost during the subsequent current quench, as no signal of relativistic runaway electrons is typically seen at the end of the current quench. In conclusion, the non-thermals appear to have an effect on the deposition profile of the SPI pellets, especially at the end of the TQ, due to increased pellet ablation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comment on “Large Enhancement in High-Energy Photoionization of Fe XVII and Missing Continuum Plasma Opacity”

Recent R-matrix calculations claim to provide a significant enhancement in the opacity of Fe XVII due to atomic core excitations and assert that this enhancement is consistent with recent measurements of higher-than-predicted iron opacities. Here this comment shows that the standard opacity models which have already been directly compared with experimental data produce photon absorption cross-sections for Fe XVII that are effectively equivalent to the R-matrix opacities reported in.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibrated simulations of Z opacity experiments that reproduce the experimentally measured plasma conditions

Recently, frequency-resolved iron opacity measurements at electron temperatures of 170–200 eV and electron densities of (0.7 – 4.0) × 10 22 cm –3 revealed a 30–400% disagreement with the calculated opacities [J. E. Bailey et al., Nature (London) 517, 56 (2015)]. The discrepancies have a high impact on astrophysics, atomic physics, and high-energy density physics, and it is important to verify our understanding of the experimental platform with simulations. Reliable simulations are challenging because the temporal and spatial evolution of the source radiation and of the sample plasma are both complex and incompletely diagnosed. In this article, we describe simulations that reproduce the measured temperature and density in recent iron opacity experiments performed at the Sandia National Laboratories Z facility. The time-dependent spectral irradiance at the sample is estimated using the measured time- and space-dependent source radiation distribution, in situ source-to-sample distance measurements, and a three-dimensional (3D) view-factor code. The inferred spectral irradiance is used to drive 1D sample radiation hydrodynamics simulations. The images recorded by slit-imaged space-resolved spectrometers are modeled by solving radiation transport of the source radiation through the sample. We find that the same drive radiation time history successfully reproduces the measured plasma conditions for eight different opacity experiments. These results provide a quantitative physical explanation for the observed dependence of both temperature and density on the sample configuration. Simulated spectral images for the experiments without the FeMg sample show quantitative agreement with the measured spectral images. The agreement in spectral profile, spatial profile, and brightness provides further confidence in our understanding of the backlight-radiation time history and image formation. Furthermore, these simulations bridge the static-uniform picture of the data interpretation and the dynamic-gradient reality of the experiments, and they will allow us to quantitatively assess the impact of effects neglected in the data interpretation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗