Search NASA⌕ Search

Engineering topics

Gonzalez, Jose

Publications and source records attributed to Gonzalez, Jose.

Anticipated Intraoperative Electron Beam Boost, External Beam Radiation Therapy, and Limb-Sparing Surgical Resection for Patients with Pediatric Soft-Tissue Sarcomas of the Extremity: A Multicentric Pooled Analysis of Long-Term Outcomes

Purpose: To perform a joint analysis of data from 3 contributing centers within the intraoperative electron-beam radiation therapy (IOERT)-Spanish program, to determine the potential of IOERT as an anticipated boost before external beam radiation therapy in the multidisciplinary treatment of pediatric extremity soft-tissue sarcomas. Methods and Materials: From June 1993 to May 2013, 62 patients (aged <21 years) with a histologic diagnosis of primary extremity soft-tissue sarcoma with absence of distant metastases, undergoing limb-sparing grossly resected surgery, external beam radiation therapy (median dose 40 Gy) and IOERT (median dose 10 Gy) were considered eligible for this analysis. Results: After a median follow-up of 66 months (range, 4-235 months), 10-year local control, disease-free survival, and overall survival was 85%, 76%, and 81%, respectively. In multivariate analysis after adjustment for other covariates, tumor size >5 cm (P=.04) and R1 margin status (P=.04) remained significantly associated with local relapse. In regard to overall survival only margin status (P=.04) retained association on multivariate analysis. Ten patients (16%) reported severe chronic toxicity events (all grade 3). Conclusions: An anticipated IOERT boost allowed for external beam radiation therapy dose reduction, with high local control and acceptably low toxicity rates. The combined radiosurgical approach needs to be tested in a prospective trial to confirm these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modelling of the internal dynamics and density in a tens of joules plasma focus device

Using MHD theory, coupled differential equations were generated using a lumped parameter model to describe the internal behaviour of the pinch compression phase in plasma focus discharges. In order to provide these equations with appropriate initial conditions, the modelling of previous phases was included by describing the plasma sheath as planar shockwaves. The equations were solved numerically, and the results were contrasted against experimental measurements performed on the device PF-50J. The model is able to predict satisfactorily the timing and the radial electron density profile at the maximum compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dose Escalation Improves Cancer-Related Events at 10 Years for Intermediate- and High-Risk Prostate Cancer Patients Treated With Hypofractionated High-Dose-Rate Boost and External Beam Radiotherapy

Purpose: To evaluate the 10-year outcomes of intermediate- and high-risk prostate cancer patients treated with a prospective dose escalation hypofractionated trial of pelvic external beam radiation therapy (P-EBRT) with a high-dose-rate (HDR) brachytherapy boost. Methods and Materials: From 1992 to 2007, 472 patients were treated with a HDR boost at William Beaumont Hospital. They had at least one of the following: a prostate-specific antigen (PSA) level of >10 ng/ml, a Gleason score of {>=}7, or clinical stage {>=}T2b. Patients received 46-Gy P-EBRT and an HDR boost. The HDR dose fractionation was divided into two dose levels. The prostate biologically equivalent dose (BED) low-dose-level group received <268 Gy, and the high-dose group received >268 Gy . Phoenix biochemical failure (BF) definition was used. Results: Median follow-up was 8.2 years (range, 0.4-17 years). The 10-year biochemical failure rate of 43.1% vs. 18.9%, (p < 0.001), the clinical failure rate of 23.4% vs. 7.7%, (p < 0.001), and the distant metastasis of 12.4% vs. 5.7%, (p = 0.028) were all significantly better for the high-dose level group. On Cox multivariate analysis, higher BED levels (p = 0.017; hazard ratio [HR]= 0.586), pretreatment PSA assays (p < 0.001, HR = 1.022), and Gleason scores (p = 0.004) were significant variables for reduced biochemical failure. Higher dose levels (p, 0.002; HR, 0.397) and Gleason scores (p < 0.001) were significant for clinical failure. Grade 3 genitourinary complications were 2% and 3%, respectively, and grade 3 gastrointestinal complication was <0.5%. Conclusions: This prospective trial using P-EBRT with HDR boost and hypofractionated dose escalation demonstrates a strong dose-response relationship for intermediate- and high-risk prostate cancer patients. The improvement at 10 years for locoregional control with higher radiation doses (BED, > 268Gy) has significantly decreased biochemical and clinical failures as well as distant metastasis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-spin binary black hole mergers

We study identical mass black hole binaries with spins perpendicular to the binary's orbital plane. These binaries have individual spins ranging from s/m{sup 2}=-0.90 to 0.90, (s{sub 1}=s{sub 2} in all cases) which is near the limit possible with standard Bowen-York puncture initial data. The extreme cases correspond to the largest initial spin simulations to date. Our results expand the parameter space covered by Rezzolla et al., and when combining both data sets, we obtain estimations for the minimum and maximum values for the intrinsic angular momenta of the remnant of binary black hole mergers of J/M{sup 2}=0.341{+-}0.004 and 0.951{+-}0.004, respectively. Note, however, that these values are reached through extrapolation to the singular cases |s{sub 1}|=|s{sub 2}|=1 and thus remain as estimates until full-fledged numerical simulations provide confirmation.

79 ASTRONOMY AND ASTROPHYSICS↗

Assembling The Marine Metagenome, One Cell At A Time

The difficulty associated with the cultivation of most microorganisms and the complexity of natural microbial assemblages, such as marine plankton or human microbiome, hinder genome reconstruction of representative taxa using cultivation or metagenomic approaches. Here we used an alternative, single cell sequencing approach to obtain high-quality genome assemblies of two uncultured, numerically significant marine microorganisms. We employed fluorescence-activated cell sorting and multiple displacement amplification to obtain hundreds of micrograms of genomic DNA from individual, uncultured cells of two marine flavobacteria from the Gulf of Maine that were phylogenetically distant from existing cultured strains. Shotgun sequencing and genome finishing yielded 1.9 Mbp in 17 contigs and 1.5 Mbp in 21 contigs for the two flavobacteria, with estimated genome recoveries of about 91% and 78%, respectively. Only 0.24% of the assembling sequences were contaminants and were removed from further analysis using rigorous quality control. In contrast to all cultured strains of marine flavobacteria, the two single cell genomes were excellent Global Ocean Sampling (GOS) metagenome fragment recruiters, demonstrating their numerical significance in the ocean. The geographic distribution of GOS recruits along the Northwest Atlantic coast coincided with ocean surface currents. Metabolic reconstruction indicated diverse potential energy sources, including biopolymer degradation, proteorhodopsin photometabolism, and hydrogen oxidation. Compared to cultured relatives, the two uncultured flavobacteria have small genome sizes, few non-coding nucleotides, and few paralogous genes, suggesting adaptations to narrow ecological niches. These features may have contributed to the abundance of the two taxa in specific regions of the ocean, and may have hindered their cultivation. We demonstrate the power of single cell DNA sequencing to generate reference genomes of uncultured taxa from a complex microbial community of marine bacterioplankton. A combination of single cell genomics and metagenomics enabled us to analyze the genome content, metabolic adaptations, and biogeography of these taxa.

08 HYDROGEN↗