Search NASA⌕ Search

Engineering topics

Goodman, Carolyn D.

Publications and source records attributed to Goodman, Carolyn D..

Design Requirements and Hardware Specification for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗