Charging Experiments and Filtration Testing on Facemask Materials: Towards Goals of Full Performance Restoration of Used N95 Masks and Enhancement of Common-Fabric Facemasks

Different techniques have been developed for sanitizing N95 masks while retaining whatever charge remains on them. However, these sanitizing methods do not address the fact that the electrical charge, filtration efficacy, and breathability of such masks may be expected to degrade during long-term use based on mechanisms known in the literature. In this study, approaches to electrically (re)charging facemask filter materials were explored in response to the COVID-19 induced shortage of N95 masks. The effort consisted of charging experiments followed by filtration testing conducted at the coupon level during a month-long period (May 2020). The main focus of the work was to develop a recharging technique which could eventually be adapted and used as part of a broader full-performance restoration process for used N95 masks, e.g., which might employ simple washing by alcohol or soapy water as a preceding step for sanitization and declogging. Most tested coupons were therefore nonwoven meltblown fibrous polypropylene (PP) filter media extracted from decades old N95 masks. Keeping in mind commonly used cloth facemasks, limited trials were also performed with some commercially available fabrics. Charging was done at elevated temperature and was followed by cooling to freeze in the applied charges produced from corona discharges using different electrode configurations and parameter combinations, or from triboelectric rubbing. Charging was also focused on using potentially scalable equipment, e.g., Van de Graaff generators or consumer ionic hair products. Some degree of success was achieved with one of the fabrics and the PP filter media which was first purposefully discharged to have typical filtration efficiency (FE) of ~35%. Numerous attempts at corona charging discharged media resulted in filtration efficiency (FE) ≥ 80 – 85%. Some measure of charge robustness was also established via stable performance during loading testing. However, results where FE ≥ 90% were not reliably repeatable and no results met the FE ≥ 95% goal due to shortcomings of the charging process. The best three trials for PP media statistically met the FE ≥ 90% criteria, amounted to a small percentage of the trials relying on an ionic hair dryer, and are attributed to good embedding of charges via aerodynamic force. Triboelectric charging significantly enhanced the viability of one of the polyester fabrics –measured FE increased from 19% up to 46% while maintaining a reasonably low pressure drop.

N95↗

Particle Loading Tests on HEPA Flat Sheet Media at Sub-Ambient Pressures Using a Lunar Dust Simulant

When humans return to the moon under the NASA Artemis program, their activities on the lunar surface will inevitably lead to the intrusion of some level of lunar dust into the lander cabin. Therein the crew would be exposed to the potential hazards of lunar dust and the possibility of subsequent transfer into orbiting segments after docking. The spacecraft’s cabin filtration system will need to be effective at removing the airborne lunar dust to properly purify the breathable cabin air and minimize the spreading of the dust throughout the vehicle and orbital segments through the mission duration. The fine nature of the lunar dust will require high efficiency filtration, such as HEPA. A series of tests were performed in a specially designed recirculating sealed flow loop, for testing filter media and filter elements at the NASA Glenn Research Center. The flow loop was used to assess the performance and capacity of flat sheet filter media at representative cabin pressures using JSC-1AF lunar dust simulant and at high rates of particle loading. The pressure drop across the filter media was measured as a function of accumulated particle mass load at ambient pressure and at two sub-ambient pressures, 0.0703MPa and 0.0565MPa, and at a media velocity that was scaled relative to its pleated configuration. The challenge particle flows were generated by a custom designed particle generator that introduces dispersed particles of the lunar simulant at high concentrations. An optical particle counting instrument provided filter efficiency measurements within the sealed environment. The pressure drop was found to increase linearly with the amount of dust load on the media, for all test conditions, while the starting pressure drop was found to be lower at the lowest sub-ambient pressure case. High filter efficiency was maintained after high particle loads on the media.

Sub-ambient↗

Particle Loading Tests on HEPA Flat Sheet Media at Sub-Ambient Pressures Using a Lunar Dust Simulant

When humans return to the moon under the NASA Artemis program, their activities on the lunar surface will inevitably lead to the intrusion of some level of lunar dust into the lander cabin. Therein the crew would be exposed to the potential hazards of lunar dust and the possibility of subsequent transfer into orbiting segments after docking. The spacecraft’s cabin filtration system will need to be effective at removing the airborne lunar dust to properly purify the breathable cabin air and minimize the spreading of the dust throughout the vehicle and orbital segments through the mission duration. The fine nature of the lunar dust will require high efficiency filtration, such as HEPA. A series of tests were performed in a specially designed recirculating sealed flow loop, for testing filter media and filter elements at the NASA Glenn Research Center. The flow loop was used to assess the performance and capacity of flat sheet filter media at representative cabin pressures using JSC-1AF lunar he filter media was measured as a function of accumulated particle mdust simulant and at high rates of particle loading. The pressure drop across tass load at ambient pressure and at two sub-ambient pressures, 0.0703MPa and 0.0565MPa, and at a media velocity that was scaled relative to its pleated configuration. The challenge particle flows were generated by a custom designed particle generator that introduces dispersed particles of the lunar simulant at high concentrations. An optical particle counting instrument provided filter efficiency measurements within the sealed environment. The pressure drop was found to increase linearly with the amount of dust load on the media, for all test conditions, while the starting pressure drop was found to be lower at the lowest sub-ambient pressure case. High filter efficiency was maintained after high particle loads on the media

Sub-ambient↗

Flight Environment HEPA Filter Testing for Lunar Dust Removal Capability

Lunar dust is an abrasive regolith that can cause critical damage to hardware and crew. Its morphology and chemical makeup differs from typical earth dust due to space weathering effects. Current space missions require extensive air filtration of lunar dust to ensure mission success; as such filtration testing is paramount in verifying the dust-removal capabilities of the system. Previous testing at NASA GRC consisted of two stages: testing a flat high efficiency particulate air (HEPA) media sheet at various pressure ranges (Stage 1) and testing a pleated HEPA filter at different humidity and dust levels (Stage 2). This testing was done to buy-down risk when testing the flight-qualification HEPA filter for the proposed Stage 3 test. Stage 3 testing used a flight-ready HEPA filter to measure its performance characteristics to verify programmatic requirements. This included measuring lunar dust loading versus pressure drop performance and establishing a maximum capacity based on the allowable pressure drop, determining the HEPA filter efficiency utilizing two separate methodologies, and assessing if the lunar dust caused the HEPA filter to experience any damage. Additionally, dust removal from the HEPA filter was performed using a vacuum to ascertain if the filter life can be prolonged. These test results will aid the program in verifying programmatic requirements and ensuring risk buydown before this HEPA filter takes flight.