Development of Carbon Dioxide Removal Systems for Advanced Exploration Systems

"NASA's Advanced Exploration Systems (AES) program is pioneering new approaches for rapidly developing prototype systems, demonstrating key capabilities, and validating operational concepts for future human missions beyond Earth orbit" (NASA 2012). These forays beyond the confines of earth's gravity will place unprecedented demands on launch systems. They must not only blast out of earth's gravity well as during the Apollo moon missions, but also launch the supplies needed to sustain a crew over longer periods for exploration missions beyond earth's moon. Thus all spacecraft systems, including those for the separation of metabolic carbon dioxide and water from a crewed vehicle, must be minimized with respect to mass, power, and volume. Emphasis is also placed on system robustness both to minimize replacement parts and ensure crew safety when a quick return to earth is not possible. Current efforts are focused on improving the current state-of-the-art systems utilizing fixed beds of sorbent pellets by seeking more robust pelletized sorbents, evaluating structured sorbents, and examining alternate bed configurations to improve system efficiency and reliability. These development efforts combine testing of sub-scale systems and multi-physics computer simulations to evaluate candidate approaches, select the best performing options, and optimize the configuration of the selected approach, which is then implemented in a full-scale integrated atmosphere revitalization test. This paper describes the carbon dioxide (CO2) removal hardware design and sorbent screening and characterization effort in support of the Atmosphere Resource Recovery and Environmental Monitoring (ARREM) project within the AES program. A companion paper discusses development of atmosphere revitalization models and simulations for this project.

Knox, James C.↗

Using Isothermal Microcalorimetry to Determine Compatibility of Structural Materials with High Test Hydrogen Peroxide (HTP) Propellant

High-Test Hydrogen Peroxide (HTP) propellant (greater than or equal to 70%) offers many advantages in space launch applications; however, materials used in construction of propulsion systems must be shown to be compatible with HTP. Isothermal Microcalorimetry (IMC) was used to determine the compatibility of several metallic and non-metallic materials with 90% HTP. The results of these experiments agreed with those from immersion bath tests when the values were converted to %Active Oxygen Loss per week (%AOL/wk).

Gostowski, Rudy↗

Isothermal Microcalorimetric Evaluation of Compatibility of Proposed Injector Materials with High-Test Hydrogen Peroxide Propellant

High-test hydrogen peroxide (HTP) is receiving renewed interest as a monopropellant and as the oxidizer for bipropellant systems. HTP is hydrogen peroxide in concentrations ranging from 70 to 98%. All surfaces wetted by HTP must be evaluated for compatibility with the fluid. In the case of tanks, lines and valves compatibility is required to preserve the HTP oxygen and energy content and to avoid overpressurization due to decomposition. With injectors and regenerative cooling passages shorter exposure time reduces these concerns. However, phase changes from fluid to gas impact heat transfer and become the dominant compatibility concern. Isothermal microcalorimetry (IMC) provides a convenient and reproducible means to observe the decomposition of HTP when exposed to structural materials and therefore the compatibility of those materials'. The instrument provides heat flow values in terms of watts that may be converted to a reaction rate given the heat of reaction for the decomposition of hydrogen peroxide. These values are then converted to percent active oxygen loss per week (%AOL/wk) to preserve an earlier convention for quantifying HTP compatibility. Additionally, qualitative designations of compatibility have been assigned to these values. This scheme consists of four classes with Class 1 being the most compatible. While historical compatibility data is available its current applicability is in question due to subtle changes in the compositions of both HTP and structural materials. Trace levels of molecules can have significant influence on compatibility. Therefore representative samples of materials must be evaluated with current HTP formulations. In this work seven materials were selected for their strength characteristics at high temperature as expected in a HTP injector. The materials were then evaluated by IMC for HTP compatibility.

Gostowski, Rudy↗

Isothermal Calorimetric Observations of the Effect of Welding on Compatibility of Stainless Steels with High-Test Hydrogen Peroxide Propellant

High-Test Hydrogen Peroxide (HTP) is receiving renewed interest as a monopropellant and as the oxidizer for bipropellant systems. HTP is hydrogen peroxide having concentrations ranging from 70 to 98%. In these applications the energy and oxygen released during decomposition of HTP is used for propulsion. In propulsion systems components must be fabricated and connected using available joining processes. Welding is a common joining method for metallic components. The goal of this study was to compare the HTP compatibility of welded vs. unwelded stainless steel.

Gostowski, Rudy↗

An Experimental Investigation of Hypergolic Ignition Delay of Hydrogen Peroxide with Fuel Mixtures

An experimental investigation of hypergolicity and ignition delay of fuel mixtures with hydrogen peroxide is presented. Example results of high speed photography and schleiren from drop tests are shown. Also, a discussion of the sensitivity to experimental parameters such as drop size and subsequent uncertainty considerations of ignition delay results is presented. It is shown that using the described setup on the mixtures presented, the precision uncertainty is on the order of 6% of average ignition delay and 5% of average decomposition delay. This represents sufficient repeatability for first order discrimination of ignition delay for propellant development and screening. Two mixtures, each using commonly available amines and transition metal compounds, are presented as examples that result in ignition delays on the order of 10 milliseconds.

Blevins, John A.↗

An Experimental Investigation of Hypergolic Ignition Delay of Hydrogen Peroxide with Fuel Mixtures

An experimental evaluation of decomposition and ignition delay of hydrogen peroxide at concentrations of 80% to 98% with combinations of hydrocarbon fuels, tertiary amines and transition metal chelates will be presented in the proposed paper. The results will be compared to hydrazine ignition delays with hydrogen peroxide and nitric acid mixtures using the same test apparatus.

Blevins, John A.↗

Using Isothermal Microcalorimetry to Determine Compatibility of Structural Materials with High-Test Hydrogen Peroxide (HTP) Propellant

High-Test Hydrogen Peroxide (HTP) propellant (equal to or greater than 70%) offers many advantages in space launch applications. However, materials used in construction of propulsion systems must be shown to be compatible with HTP. Isothermal Microcalorimetry (IMC) was used to determine the compatibility of several metallic and non-metallic materials with 90% HTP. The results of these experiments agreed with those from immersion bath tests when the values were converted to % Active Oxygen Loss per week (%AOL/wk).

Gostowski, Rudy↗

Assessment of The Compatibility of Composite Materials With High-Test Hydrogen Peroxide

The compatibility of composite materials with high-test hydrogen peroxide (HTP) was assessed using various chemical and mechanical techniques. Methods included classical schemes combining concentration assay with accelerated aging by means of a heated water bath. Exothermic reactivity was observed using Isothermal Microcalorimetry. Mechanical Properties testing determined degradation of the composite material. Photoacoustic Infrared Spectroscopy was used to monitor chemical alteration of the resin matrix. Other materials were examined including some polymers and metals.

Gostowski, Rudy↗

Materials Compatibility in High Test Hydrogen Peroxide

Previous ratings of the compatibility of high test hydrogen peroxide (HTP) with materials are not adequate for current needs. The goal of this work was to develop a new scheme of evaluation of compatibility of HTP with various materials. Procedures were developed to enrich commercially available hydrogen peroxide to 90% concentration and to assay the product. Reactivity testing, accelerated aging of materials and calorimetry studies were done on HTP with representative metallic and non-metallic materials. It was found that accelerated aging followed by concentration determination using refractive index effectively discriminated between different Class 2 metallic materials. Preliminary experiments using Differential Scanning Calorimetry (DSC) suggest that a calorimetry experiment is the most sensitive means to assay the compatibility of HTP with materials.

Gostowski, Rudy↗