Search NASA⌕ Search

Engineering topics

Goudey, Howdy

Publications and source records attributed to Goudey, Howdy.

DIY Affordable Window Shading

This document shows how you can easily and affordably shade your windows to keep your home from getting too hot on sunny days. This phenomenon (what researchers call “solar heat gain”) can threaten occupant comfort and safety, especially during heatwaves. Still, many homes lack adequate protection. All of these solutions can be implemented inexpensively using common household items or items that can easily be purchased online. Additionally, you don’t need specialized tools or expertise to install them. Note that these are ideally temporary fixes, so households with sufficient means should still pursue permanent ones (e.g.,shades—preferably on the outside—or specialized windows or films). In their absence, the stopgap measures described below can help protect you and your loved ones during heatwaves and other exceptional events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hot, cold, or just right? An infrared biometric sensor to improve occupant comfort and reduce overcooling in buildings via closed-loop control

To improve occupant comfort and save energy in buildings, we have developed a closed-loop air conditioning (AC) sensor-controller that predicts occupant thermal sensation from the thermographic measurement of skin temperature distribution, then uses this information to reduce overcooling (cooling-energy overuse that discomforts occupants) by regulating AC output. Taking measures to protect privacy, it combines thermal-infrared (TIR) and color (visible spectrum) cameras with machine vision to measure the skin-surface temperature profile. Since the human thermoregulation system uses skin blood flow to maintain thermoneutrality, the distribution of skin temperature can be used to predict warm, neutral, and cool thermal states. We conducted a series of human-subject thermal-sensation trials in cold-to-hot environments, measuring skin temperatures and recording thermal sensation votes. We then trained random-forest classification machine-learning models (classifiers) to estimate thermal sensation from skin temperatures or skin-temperature differences. The estimated thermal sensation was input to a proportional integral (PI) control algorithm for the AC, targeting a sensation level between neutral and warm. Our sensor-controller includes a sensor assembly, server software, and client software. The server software orients the cameras and transmits images to the client software, which in turn assesses occupant skin temperature distribution, estimates occupant thermal sensation, and controls AC operation. A demonstration conducted in a conference room in an office building near Houston, TX showed that our system reduced overcooling, decreasing AC load by 42% when the room was occupied while improving occupant comfort (fraction of “comfortable” votes) by 15 percentage points.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative study on the overall energy performance between photovoltaic and Low-E insulated glass units

In this report a novel semi-transparent building integrated photovoltaic (BIPV) laminate was developed and introduced in this paper. It was produced by cutting standard mono-crystalline silicon solar cells into small strips and then making electrical connections between each strip before laminating the cells between two layers of glass. The overall energy performance and energy saving potential of the BIPV insulated glass unit (IGU) under real world conditions were identified through a side by side comparative study. Compared to the reference IGU, the BIPV IGU had lower solar heat gain coefficient (SHGC) but much higher U-factor. The average HVAC electricity saving of the BIPV IGU was about 10% relative to the reference IGU. Daylighting measurement and analysis were carried out to evaluate the trade-offs associated with the BIPV IGU between daylight, glare, and lighting energy use. The results indicated that the BIPV IGU is better than the reference IGU in reducing discomfort glare. However, if the most conservative viewpoint near the window is used for the assessment, a lower transmittance BIPV IGU is required to bring the overall discomfort levels below the perceptible level. Lastly, the net energy saving potential associated with the novel BIPV IGU was identified based on the power, thermal and daylighting performance. On average, the BIPV IGU saved 16.8% of the total electricity use of the room. Further studies and improvement on the energy conversion efficiency of solar cells, the optimal transmittance as well as the thermal properties would make this technology more energy-efficient and affordable.

14 SOLAR ENERGY↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, characterization, and fabrication of solar-retroreflective cool-wall materials

Raising urban albedo increases the fraction of incident sunlight returned to outer space, cooling cities and their buildings. We evaluated the angular distribution of solar radiation incident on exterior walls in 17 U S. climates to develop performance parameters for solar-retroreflective walls, then applied first-principle physics and ray-tracing simulations to explore designs. Our analysis indicates that retroreflective walls must function at large incidence angles to reflect a substantial portion of summer sunlight, and that this will be difficult to attain with materials that rely on total internal reflection. Gonio-spectrophotometer measurements of the solar spectral bi-directional reflectivity of a bicycle reflector showed little to no retroreflection at large incidence angles. Visual comparisons of retroreflection to specular first-surface reflection for four different retroreflective safety films using violet and green lasers suggest their retroreflection to be no greater than 0.09 at incidence angles up to 45°, and no greater than 0.30 at incidence angles of up to 70°. Attempts to produce a two-surface retroreflector with orthogonal mirror grooves by cutting and polishing an aluminum block indicate that residual surface roughness impedes retroreflection. Ongoing efforts focus on forming orthogonal surfaces with aluminized Mylar film, a material with very high specular reflectance across the solar spectrum. We investigated (1) folding or stamping a free film; (2) adhering the film to a pre-shaped substrate; or (3) attaching the film to a flat ductile substrate, then shaping. The latter two methods were more successful but yielded imperfect right angles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

utility incentives↗

Monitoring the Urban Heat Island Effect and the Efficacy of Future Countermeasures

To relate fine-scale spatial air-temperature variations in local urban heat islands and urban cool islands—increases and decreases in outside air temperature—within a large urban-climate archipelago to variations in land-use and land-cover properties in the Los Angeles Basin, the research team sought to (a) use fine-resolution meso-urban climate models to identify areas of urban heat and cool islands, select sites for fixed weather monitoring, and choose routes for mobile observations; (b) relate observed intraurban temperature variations to land use and land cover and surface physical properties; and (c) calibrate/validate the climate models. The research team assessed urban temperature variations via simulations and observations, including mobile transects, mesonet, dense networks of personal weather stations, and sparse but more accurate research-grade monitors. To identify the causative factors of the urban heat and cool islands at the neighborhood scale, the research team collected detailed urban morphometric and land use and land cover datasets, such as 1-meter (3.3 foot) resolution roof albedo (solar reflectance) and tree canopy cover. The research team used the observationvalidated model to finalize the transect routes and site the stationary monitors. This study provides the first observational evidence from analysis of high-spatial-density weather stations that increases in roof albedo at neighborhood scale are associated with reductions in near-surface air temperature. This finding was corroborated with the analysis from mobile transect measurements and correlation of observed air temperature with neighborhood-scale albedo and vegetation. This correlation revealed a cooling effect from areawide increase in albedo or canopy cover or both. The calibrated meteorological model accurately identified the localized urban heat and cool islands observed in this study. Interested stakeholders/researchers can use the same models and calibration/validation methodology to characterize within-city microclimate variations elsewhere in California, and can apply them to analyze the benefits from using urban heat island countermeasures. This project report is an extended and more detailed version of a related report prepared for California’s Fourth Climate Change Assessment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental validation for thermal transmittances of window shading systems with perimeter gaps

Virtually all residential and commercial windows in the U.S. have some form of window attachment, but few have been designed for energy savings. ISO 15099 presents a simulation framework to determine thermal performance of window attachments, but the model has not been validated for these products. This paper outlines a review and validation of the ISO 15099 centre-of-glass heat transfer correlations for perimeter gaps (top, bottom, and side) in naturally ventilated cavities through measurement and simulation. The thermal transmittance impact due to dimensional variations of these gaps is measured experimentally, simulated using computational fluid dynamics, and simulated utilizing simplified correlations from ISO 15099. Results show that the ISO 15099 correlations produce a mean error between measured and simulated heat flux of 2.5 ± 7%. These tolerances are similar to those obtained from sealed cavity comparisons and are deemed acceptable within the ISO 15099 framework.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental validation and model development for thermal transmittances of porous window screens and horizontal louvred blind systems

Virtually every home in the US has some form of shades, blinds, drapes, or other window attachment, but few have been designed for energy savings. In order to provide a common basis of comparison for thermal performance it is important to have validated simulation tools. This study outlines a review and validation of the ISO 15099 centre-of-glass thermal transmittance correlations for naturally ventilated cavities through measurement and detailed simulations. The focus is on the impacts of room-side ventilated cavities, such as those found with solar screens and horizontal louvred blinds. The thermal transmittance of these systems is measured experimentally, simulated using computational fluid dynamics analysis, and simulated utilizing simplified correlations from ISO 15099. Finally, correlation coefficients are proposed for the ISO 15099 algorithm that reduces the mean error between measured and simulated heat flux for typical solar screens from 16% to 3.5% and from 13% to 1% for horizontal blinds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research Needs: Glass Solar Reflectance and Vinyl Siding

The subject of glass solar reflectance and its contribution to permanent vinyl siding distortion has not been extensively studied, and some phenomena are not yet well understood. This white paper presents what is known regarding the issue and identifies where more research is needed. Three primary topics are discussed: environmental factors that control the transfer of heat to and from the siding surface; vinyl siding properties that may affect heat build-up and permanent distortion; and factors that determine the properties of reflected solar radiation from glass surfaces, including insulating window glass. Further research is needed to fully characterize the conditions associated with siding distortion, the scope of the problem, physical properties of vinyl siding, insulating window glass reflection characteristics, and possible mitigation or prevention strategies.

14 SOLAR ENERGY↗

Key Elements of and Materials Performance Targets for Highly Insulating Window Frames

The thermal performance of windows is important for energy efficient buildings. Windows typically account for about 30-50 percent of the transmission losses though the building envelope, even if their area fraction of the envelope is far less. The reason for this can be found by comparing the thermal transmittance (U-factor) of windows to the U-factor of their opaque counterparts (wall, roof and floor constructions). In well insulated buildings the U-factor of walls, roofs an floors can be between 0.1-0.2 W/(m2K). The best windows have U-values of about 0.7-1.0. It is therefore obvious that the U-factor of windows needs to be reduced, even though looking at the whole energy balance for windows (i.e. solar gains minus transmission losses) makes the picture more complex.In high performance windows the frame design and material use is of utmost importance, as the frame performance is usually the limiting factor for reducing the total window U-factor further. This paper describes simulation studies analyzing the effects on frame and edge-of-glass U-factors of different surface emissivities as well as frame material and spacer conductivities. The goal of this work is to define materials research targets for window frame components that will result in better frame thermal performance than is exhibited by the best products available on the market today.

15 GEOTHERMAL ENERGY↗

Experimental and Numerical Examination of the Thermal Transmittance of High Performance Window Frames

While window frames typically represent 20-30percent of the overall window area, their impact on the total window heat transfer rates may be much larger. This effect is even greater in low-conductance (highly insulating) windows which incorporate very low conductance glazings. Developing low-conductance window frames requires accurate simulation tools for product research and development. The Passivhaus Institute in Germany states that windows (glazing and frames, combined) should have U-values not exceeding 0.80 W/(m??K). This has created a niche market for highly insulating frames, with frame U-values typically around 0.7-1.0 W/(m2 cdot K). The U-values reported are often based on numerical simulations according to international simulation standards. It is prudent to check the accuracy of these calculation standards, especially for high performance products before more manufacturers begin to use them to improve other product offerings. In this paper the thermal transmittance of five highly insulating window frames (three wooden frames, one aluminum frame and one PVC frame), found from numerical simulations and experiments, are compared. Hot box calorimeter results are compared with numerical simulations according to ISO 10077-2 and ISO 15099. In addition CFD simulations have been carried out, in order to use the most accurate tool available to investigate the convection and radiation effects inside the frame cavities. Our results show that available tools commonly used to evaluate window performance, based on ISO standards, give good overall agreement, but specific areas need improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗