LIBS Application to Liquid Samples Chapter 9
Chapter 9 from the book "Laser-Induced Breakdown Spectroscopy"
Engineering topics
Publications and source records attributed to Goueguel, Christian.
Chapter 9 from the book "Laser-Induced Breakdown Spectroscopy"
Presented by NETL at ScIX 2017, 10/17
Presented by NETL at 2017 AIChE Annual Meeting, 10/17
Presented by NETL at South Eastern Geological Society of America, 3/17
Presented by NETL at GSA, 3/17
Presented by NETL at Geological Society of America. 9/16
Presented by NETL at SCIX 2016, 9/16
Presented by NETL at CCUS 2016, 6/16
A significant portion of the carbon sequestration research being performed in the United States involves the risk assessment of injecting large quantities of carbon dioxide into deep saline aquifers. Leakage of CO 2 has the potential to affect the quality of groundwater supplies in case contaminants migrate through underlying conduits. New remote sensing and near-surface monitoring technologies are needed to ensure that injection, abandoned, and monitoring wells are structurally sound, and that CO 2 remains within the geologic storage reservoir. In this paper, we propose underwater laser-induced breakdown spectroscopy (underwater LIBS) as an analytical method for monitoring naturally occurring elements that can act as tracers to detect a CO 2 leak from storage sites. Laboratory-scale experiments were conducted to measure Sr 2+ , Ca 2+ , K + , and Li + in bulk solutions to ascertain the analytical performance of underwater LIBS. We compared the effect of NaCl, Na 2 CO 3 , and Na 2 SO 4 on the analytes calibration curves to determine underwater LIBS’ ability to analyze samples of sodium compounds. In all cases, the calibration curves showed a good linearity within 2 orders of magnitude. The limit of detections (LODs) obtained for K + (30±1 ppb) and Li + (60±2 ppb) were in ppb range, while higher LODs were observed for Ca 2+ (0.94±0.14 ppm) and Sr 2+ (2.89±0.11 ppm). Evaluation of the calibration curves for the analytes in mixed solutions showed dependence of the lines’ intensity with the sodium compounds. The intensities increased respectively in the presence of dissolved NaCl and Na 2 SO 4 , whereas the intensities slightly decreased in the presence of Na 2 CO 3 . Lastly, the capabilities of underwater LIBS to detect certain elements in the ppb or in the low ppm range make it particularly appealing for in situ monitoring of a CO 2 leak.
Explore the source record for details and available documents.
Explore the source record for details and available documents.