X-Ray and Gamma-Ray Astronomy with NTD Germanium-based Microcalorimeters

We report on the performance of our NTD-Ge microcalorimeters. To date, the spectral resolution for x-ray and gamma-ray lines from radioactive sources and laboratory plasmas is 4.8 eV in the entire 1 - 6 keV band and 52 eV at 60 keV. Technical details responsible for this performance are presented as well as an innovative electro-thermal approach for enhancing count-rate capability.

Silver, E.↗

Feasibility of KTa(1-x)Nb(x)O3 as a dielectric or pyroelectric microcalorimeter

We are developing a dielectric microcalorimeter for X-ray spectroscopy. We will present the results of our measurement of the dielectric permittivity, the spontaneous polarization, and the pyroelectric coefficient of the mixed-crystal quantum ferroelectric KTa(1-x)Nb(x)O3 with a doping of x = 0.012, as a function of temperature and bias voltage across the device. The effects of surface layers on the permittivity and the pyroelectric coefficient are discussed. We also show the signal results from infrared LED and alpha-particle radiation.

Pfafman, T. E.↗

A new thermal sensor for X-ray microcalorimetry

A concept for a detector is introduced which exploits the significant temperature dependence of the dielectric constant in ferroelectric materials. The concept permits the use of a microcalorimeter without the resistive sensors which are associated with heat dissipation and increased Johnson noise in the electronic conversion circuit. General calorimeter features are listed, and the concepts related to dielectric calorimeters are discussed in terms of operational and detection advantages. The use of the device is delineated both theoretically and experimentally with the results of an operational dielectric material. The mixed-crystal quantum ferroelectric is employed and detects 6 MeV alpha particles while operating at 1.2 K in the first detection conducted. The temperature dependence of the dielectric constant in the materials allows for the elimination of resistive sensors in microcalorimeters, thereby improving the ultimate sensitivity of the instrument.

Silver, Eric↗

Test results of a prototype dielectric microcalorimeter

The initial development work on a dielectric microcalorimeter is presented. It focuses on the dielectric properties of the ferroelectric material KTa(1-x)Nb(x)O3 (KTN). Measurements of the temperature dependent dielectric constant are given together with the first alpha particle detection results from a prototype composite microcalorimeter operating at 1.3 K. A nonthermal mechanism for detecting 6 MeV alpha particles in a monolithic KTN sample is also reported.

Pfafman, T. E.↗