Search NASA⌕ Search

Engineering topics

Grace, E.

Publications and source records attributed to Grace, E..

At least 19 records

Ultra-compact x-ray spectrometer for high-repetition-rate laser–plasma experiments

Here, we present in this work the development of an ultra-compact, multi-channel x-ray spectrometer (UCXS). This diagnostic has been specially built and adapted to perform at high-repetition-rate (>1 Hz) for high-intensity, short-pulse laser plasma experiments. X-ray filters of varying materials and thicknesses are chosen to provide spectral resolution up to ΔE ≈ 1 keV over the x-ray energy range of 1–30 keV. These filters are distributed over a total of 25 channels, where each x-ray filter is coupled to a single scintillator. The UCXS is designed to detect and resolve a large variety of laser-driven x-ray sources such as low energy bremsstrahlung emission, fluorescence, and betatron radiation (up to 30 keV). Preliminary results from commissioning experiments at the ABL laser facility at Colorado State University are provided.

47 OTHER INSTRUMENTATION↗

Scaling of laser-driven electron and proton acceleration as a function of laser pulse duration, energy, and intensity in the multi-picosecond regime

A scaling study of short-pulse laser-driven proton and electron acceleration was conducted as a function of pulse duration, laser energy, and laser intensity in the multi-picosecond (ps) regime (∼0.8 ps–20 ps). Maximum proton energies significantly greater than established scaling laws were observed, consistent with observations at other multi-ps laser facilities. In addition, maximum proton energies and electron temperatures in this regime were found to be strongly dependent on the laser pulse duration and preplasma conditions. A modified proton scaling model is presented that is able to better represent the accelerated proton characteristics in this multi-ps regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of TNSA proton radiography on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) Laser

We report that proton radiography using short-pulse laser drivers is an important tool in high-energy density (HED) science for dynamically diagnosing key characteristics in plasma interactions. Here we detail the first demonstration of target-normal sheath acceleration (TNSA)-based proton radiography the NIF-ARC laser system aided by the use of compound parabolic concentrators (CPCs). The multi-kJ energies available at the NIF-ARC laser allows for a high-brightness proton source for radiography and thus enabling a wide range of applications in HED science. In this demonstration, proton radiography of a physics package was performed and this work details the spectral properties of the TNSA proton probe as well as description of the resulting radiography quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerating the rate of discovery: toward high-repetition-rate HED science

As high-intensity short-pulse lasers that can operate at high-repetition-rate (HRR) (>10 H z ) come online around the world, the high energy density (HED) science they enable will experience a radical paradigm shift. The >10 3 increase in shot rate over today's shot-per-hour drivers translates into dramatically faster data acquisition, more experiments, and the ability to exploit machine learning, and thus the potential to significantly accelerate the advancement of HED science. A wide range of HED experiments, from opacity investigations to secondary source generation to plasma nuclear physics, will benefit from the increased statistics, precision, and exploration of phase space. Besides increasing the rate at which scientific experiments can be performed, HRR also allows for the rapid delivery of optimal experiments supported by simulations and modeling augmented by close coupling to empirical data. To fully realize such an HRR framework, numerous subsystems must be developed and brought together, including feedback laser control loops, high-throughput targetry and diagnostics, cognitive simulation, enhanced HED codes, and advanced data analytics. This paper describes the vision for an integrated HRR laser experimental HED system and outlines some of the major considerations and challenges for realizing it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a deep learning based automated data analysis for step-filter x-ray spectrometers in support of high-repetition rate short-pulse laser-driven acceleration experiments

We present a deep learning based framework for real-time analysis of a differential filter based x-ray spectrometer that is common on short-pulse laser experiments. The analysis framework was trained with a large repository of synthetic data to retrieve key experimental metrics, such as slope temperature. With traditional analysis methods, these quantities would have to be extracted from data using a time-intensive and manual analysis. Furthermore, this framework was developed for a specific diagnostic, but may be applicable to a wide variety of diagnostics common to laser experiments and thus will be especially crucial to the development of high-repetition rate (HRR) diagnostics for HRR laser systems that are coming online.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulations of wavelength-multiplexed holography for single-shot spatiotemporal characterization of NIF’s advanced radiographic capability (ARC) laser

We simulate the use of a newly developed single-shot wavelength-multiplexed holography-based diagnostic, STRIPED FISH, to fully characterize the as-delivered laser pulses of the National Ignition Facility’s Advanced Radiographic Capability (NIF-ARC) laser. To that end, we have performed simulations of the NIF-ARC pulse incorporating (a) a time-integrated spatial-profile measurement and a complete temporal-intensity-and-phase measurement using a frequency resolved optical gating, but without any spatiotemporal pulse characterizations, and (b) simulated first-order spatiotemporal distortions, which could be measured on a single shot if a STRIPED FISH device were deployed.

47 OTHER INSTRUMENTATION↗

Scaling of laser-driven electron and proton acceleration as a function of laser pulse duration, energy, and intensity in the multi-picosecond regime

A scaling study of short-pulse laser-driven proton and electron acceleration was conducted as a function of pulse duration, laser energy, and laser intensity in the multi-picosecond (ps) regime (~0.8 ps–20 ps). Furthermore, maximum proton energies significantly greater than established scaling laws were observed, consistent with observations at other multi-ps laser facilities. In addition, maximum proton energies and electron temperatures in this regime were found to be strongly dependent on the laser pulse duration and preplasma conditions. A modified proton scaling model is presented that is able to better represent the accelerated proton characteristics in this multi-ps regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. Finally, the characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of the DEAP-3600 dark matter detector

The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is 10 –46 cm 2 for a 100 GeV/c 2 WIMP mass with a fiducial exposure of 3 tonne-years. In conclusion, this paper describes the physical properties and construction of the DEAP-3600 detector.

79 ASTRONOMY AND ASTROPHYSICS↗

The Atacama Cosmology Telescope: The Polarization-Sensitive ACTPol Instrument

The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3° field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev–Zel'dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

79 ASTRONOMY AND ASTROPHYSICS↗

The Atacama Cosmology Telescope: The Polarization-Sensitive ACTPol Instrument

The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3deg field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev-Zel'dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

Telescope↗

Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy β and nuclear recoils in liquid argon with DEAP-1

The DEAP-1 low-background liquid argon detector has been used to measure scintillation pulse shapes of beta decays and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination down to an electron-equivalent energy of 20 keV ee . The relative intensities of singlet/triplet states in liquid argon have been measured as a function of energy between 15 and 500 keVee for both beta and nuclear recoils. Using a triple-coincidence tag we find the fraction of beta events that are misidentified as nuclear recoils to be less than 6 x 10 -8 between 43-86 keV ee and that the discrimination parameter agrees with a simple analytic model. The discrimination measurement is currently limited by nuclear recoils induced by cosmic-ray generated neutrons, and is expected to improve by operating the detector underground at SNOLAB. The analytic model predicts a beta misidentification fraction of 10 -10 for an electron-equivalent energy threshold of 20 keV ee . This reduction allows for a sensitive search for spin-independent scattering of WIMPs from 1000 kg of liquid argon with a WIMP-nucleon cross-section sensitivity of 10 -46 cm 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The First Multichroic Polarimeter Array on the Atacama Cosmology Telescope: Characterization and Performance

The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive receiver for the 6-meter Atacama Cosmology Telescope (ACT) and measures the small angular scale polarization anisotropies in the cosmic microwave background (CMB). The full focal plane is composed of three detector arrays, containing over 3000 transition edge sensors (TES detectors) in total. The first two detector arrays, observing at 146 gigahertz, were deployed in 2013 and 2014, respectively. The third and final array is composed of multichroic pixels sensitive to both 90 and 146 gigahertz and saw first light in February 2015. Fabricated at NIST, this dichroic array consists of 255 pixels, with a total of 1020 polarization sensitive bolometers and is coupled to the telescope with a monolithic array of broad-band silicon feedhorns. The detectors are read out using time-division SQUID multiplexing and cooled by a dilution refrigerator at 110 meter Kelvins. We present an overview of the assembly and characterization of this multichroic array in the lab, and the initial detector performance in Chile. The detector array has a TES detector electrical yield of 85 percent, a total array sensitivity of less than 10 microns Kelvin root mean square speed, and detector time constants and saturation powers suitable for ACT CMB observations.

Ho, S. P.↗

Design and Deployment of a Multichroic Polarimeter Array on the Atacama Cosmology Telescope

We present the design and the preliminary on-sky performance with respect to beams and pass bands of a multichroic polarimeter array covering the 90 and 146 GHz cosmic microwave background bands and its enabling broad-band optical system recently deployed on the Atacama Cosmology Telescope (ACT). The constituent pixels are feedhorn-coupled multichroic polarimeters fabricated at NIST. This array is coupled to the ACT telescope via a set of three silicon lenses incorporating novel broad-band metamaterial anti-reflection coatings. This receiver represents the first multichroic detector array deployed for a CMB experiment and paves the way for the extensive use of multichroic detectors and broad-band optical systems in the next generation of CMB experiments.

passbands↗

High-Density Superconducting Cables for Advanced ACTPol

Advanced ACTPol (AdvACT) is an upcoming Atacama Cosmology Telescope (ACT) receiver upgrade, scheduled to deploy in 2016, that will allow measure- ment of the cosmic microwave background polarization and temperature to the highest precision yet with ACT. The AdvACT increase in sensitivity is partly provided by an increase in the number of transition-edge sensors (TESes) per array by up to a factor of two over the current ACTPol receiver detector arrays. The high-density AdvACT TES arrays require 70 μ m pitch superconducting flexible cables (flex) to connect the detec- tor wafer to the first-stage readout electronics. Here, we present the flex fabrication process and test results. For the flex wiring layer, we use a 400-nm-thick sputtered alu- minum film. In the center of the cable, the wiring is supported by a polyimide substrate, which smoothly transitions to a bare (uncoated with polyimide) silicon substrate at the ends of the cable for a robust wedge wire-bonding interface. Tests on the first batch of flex made for the first AdvACT array show that the flex will meet the requirements for AdvACT, with a superconducting critical current above 1 mA at 500 mK, resilience to mechanical and cryogenic stress, and a room temperature yield of 97%.

transition-edge sensors (TESes)↗

SIMULATION OF ASTRONOMICAL IMAGES FROM OPTICAL SURVEY TELESCOPES USING A COMPREHENSIVE PHOTON MONTE CARLO APPROACH

We present a comprehensive methodology for the simulation of astronomical images from optical survey telescopes. We use a photon Monte Carlo approach to construct images by sampling photons from models of astronomical source populations, and then simulating those photons through the system as they interact with the atmosphere, telescope, and camera. We demonstrate that all physical effects for optical light that determine the shapes, locations, and brightnesses of individual stars and galaxies can be accurately represented in this formalism. By using large scale grid computing, modern processors, and an efficient implementation that can produce 400,000 photons s{sup −1}, we demonstrate that even very large optical surveys can be now be simulated. We demonstrate that we are able to (1) construct kilometer scale phase screens necessary for wide-field telescopes, (2) reproduce atmospheric point-spread function moments using a fast novel hybrid geometric/Fourier technique for non-diffraction limited telescopes, (3) accurately reproduce the expected spot diagrams for complex aspheric optical designs, and (4) recover system effective area predicted from analytic photometry integrals. This new code, the Photon Simulator (PhoSim), is publicly available. We have implemented the Large Synoptic Survey Telescope design, and it can be extended to other telescopes. We expect that because of the comprehensive physics implemented in PhoSim, it will be used by the community to plan future observations, interpret detailed existing observations, and quantify systematics related to various astronomical measurements. Future development and validation by comparisons with real data will continue to improve the fidelity and usability of the code.

79 ASTRONOMY AND ASTROPHYSICS↗

Update on the MiniCLEAN dark matter experiment

The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A² dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional ³⁹Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗