Search NASASearch

Engineering topics

Grana, D. C.

Publications and source records attributed to Grana, D. C..

Continuously Variable Transmission

Chain slides along two cones, in novel transmission concept. Transmission includes chain drive between two splined shafts. Chain sprockets follow surfaces of two cones. As one chain sprocket moves toward smaller diameter other chain sprocket moves toward larger diameter, thereby changing "gear" ratio. Movement initiated by tension applied to chain by planetary gear mechanism. Device positive, simple, and efficient over wide range of speed ratios.

Grana, D. C.

Vertical shaft windmill

A vertical shaft has several equally spaced blades mounted. Each blade consists of an inboard section and an outboard section skew hinged to the inboard section. The inboard sections automatically adjust their positions with respect to the fixed inboard sections with changes in velocity of the wind. This windmill design automatically governs the maximum rotational speed of shaft.

Grana, D. C.

Flowthrough Bacteria-Detection System

Online system allows repetitive cycling of sample intake, bacteria counting and sterilization. System measures bacteria count by using sample/incubate/ measure cycle. Steps in cycle are on/off operations to cycle automated easily.

Grana, D. C.

Natural turbulence electrical power generator

An energy conversion apparatus is disclosed in which a stator, fixed to a watertight housing, is coupled to a rotor by a helical spring which suspends the rotor from the housing. Natural turbulence of a fluid, such as water or air, causes acceleration of the housing, and hence, acceleration of the stator. Inertia of the rotor, coupled to the stator through the helical spring and the housing, causes relative motion, both longitudinal and rotational, between the stator and the rotor. The rotational motion between the rotor, and the stator is used to generate electrical current.

Grana, D. C.

Investigation of effects of temperature, salinity, and electrode design on the performance of an electrochemical coliform detector

The results of two research programs to determine the optimum detector design for measuring fecal coliforms in saline waters for operational systems are presented. One program was concerned with the effects of temperature and salinity on endpoint response time, and the other, the interaction between electrode configurations and the test organisms. Test results show that the endpoint response time is related to salinity and seawater temperature; however, these results can be minimized by the correct choice of growth media. Electrode configurations were developed from stainless steel, Parlodion-coated stainless steel, and platinum that circumvented problems associated with the commercial redox electrodes.

Grana, D. C.

Description and field test of an in situ coliform monitoring system

A prototype in situ system for monitoring the levels of fecal coliforms in shallow water bodies was developed and evaluated. This system was based on the known relationship between the concentration of the coliform bacteria and the amount of hydrogen they produce during growth in a complex organic media. The prototype system consists of a sampler platform, which sits on the bottom; a surface buoy, which transmits sampler-generated data; and a shore station, which receives, displays the data, and controls the sampler. The concept of remote monitoring of fecal coliform concentrations by utilizing a system based on the electrochemical method was verified during the evaluation of the prototype.

Grana, D. C.

Remote water monitoring system

A remote water monitoring system is described that integrates the functions of sampling, sample preservation, sample analysis, data transmission and remote operation. The system employs a floating buoy carrying an antenna connected by lines to one or more sampling units containing several sample chambers. Receipt of a command signal actuates a solenoid to open an intake valve outward from the sampling unit and communicates the water sample to an identifiable sample chamber. Such response to each signal receipt is repeated until all sample chambers are filled in a sample unit. Each sample taken is analyzed by an electrochemical sensor for a specific property and the data obtained is transmitted to a remote sending and receiving station. Thereafter, the samples remain isolated in the sample chambers until the sampling unit is recovered and the samples removed for further laboratory analysis.

Grana, D. C.

Electrical generator uses ocean waves

Device converts up-and-down motion of ocean to electrical energy. Plunging generator delivers energy to be stored in battery and used to operate remote data gathering stations. Concept may be applied to land or air use if plunging motion is supplied.

Grana, D. C.

Remote water-monitoring system

General-purpose, water-quality sampling process detects microorganisms and integrates sampling, sample preservation, and sample analysis. System overcomes difficulties in correlation of surface measurements with remote measurements and minimizes human error in handling of samples and instrumentation.

Grana, D. C.