Report on Initial Sodium Testing on the Thermal Hydraulic Experimental Test Article (THETA) (Fiscal Year 2024 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as to acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal thermal hydraulic conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. In fiscal year 2023, thermal stratification tests were completed with the primary system online, while the secondary system was being constructed [1]. These tests had shown that the core barrel and intermediate heat exchanger (IHX) outlet required increased thermal insulation. The THETA primary system was removed from METL, cleaned, thermal insulators installed, and then inserted into METL Test Vessel 4. At the time of this writing the THETA primary and secondary system are operational. During this fiscal year 100+ hours of testing was completed to characterize thermal hydraulic phenomena associated with steady state and transient conditions in a pool type liquid metal cooled reactor. A majority of the testing campaign was completed to satisfy the experimental data acquisition requirements for the GAIN Voucher with Oklo, CRADA 2021-21121. THETA is still operational at the time of this publication and future testing is planned for fiscal year 2025. Work is underway to publish existing and future data to an online database to facilitate collaboration with SFR engineers looking to validate their systems code or computational fluid dynamics models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mechanisms Engineering Test Loop (METL) Operations and Testing Report (FY2022)

This report documents the operations, testing, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) during FY2022. The METL facility had a very successful fourth year of operations and went through some new experiences such as taking the facility from its frozen state in October 2021 and thawing the facility and also recovering from an oxide plug in one of the cold trap lines. After the facility was fully thawed, the METL staff maintained the facility in a continuous molten state – either flowing sodium or a static flow condition. METL facility continued supporting the Gear Test Assembly (GTA) testing and hosted its first 28” test vessel experiment, called the Thermal Hydraulic Experimental Test Article (THETA) which was inserted into Test Vessel 4. Work to accommodate two additional experiments, a gripper test article (GrTA) and a flow sensor test article (F-STAr) continued as they are expected to make their debut in FY2023. In addition, the steam piping for the B308 scrubber unit was replaced with stainless steel piping and controls and new parts for the scrubber were purchased – such as a new pump, new storage tank, and new blower and motor. These components will ultimately replace the existing scrubber components when those 1970’s era require replacement.

42 ENGINEERING↗

Metal fuel relocation experiments with pressure injection

A pool-type sodium-cooled fast reactor (SFR) using metal fuels has a number of inherent safety features that can support benign consequences for design basis accidents (DBAs). Even in postulated severe accident conditions, the core is designed to remain under sub-critical condition in a passive coolable geometry. In case of the postulated severe accidents in SFRs, fuel relocation in the core region along the coolant channel is an important negative reactivity feedback factor that lowers the reactor power level and consequently eliminates the possibility of recriticality. Therefore, understanding the relocation behavior of fuels and the coolability of the relocated fuels in the postulated severe accident is one of the most important factors in the safety assessment of SFRs. In the present study, the relocation behavior of the metal fuel in a pin bundle geometry was investigated by injecting the metal fuels into the coolant channels with pressure. The first metal fuel relocation with pressure injection (RPI-1) experiment showed that many of the metal fuels levitated to upper plenum. In case of RPI-2 experiment, the Real Time X-ray Video System (RTXVS) was constructed and used to obtain a real time X-ray video of the experiment. This real time X-ray video clearly showed the relocation behavior of the pressure injected metallic uranium in the sodium coolant channel. Through this video, it was confirmed that part of the fuel was dispersed downward and part of the fuel was dispersed upward, and the relocation behavior of the injected fuel proceeded simultaneously in the downward and upward directions. So, it can be concluded that in case of pressure injection of the metallic fuel, there is a possibility that the metallic fuel can be quickly removed from the core region, resulting in a negative reactivity feedback effect.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Temperature Sodium Submersible Flowmeter Design and Analysis

This work details the design and analysis of a permanent magnet flowmeter designed to be submerged in a pool type sodium fast reactor environment. Recently developed Samarium Cobalt rare earth magnets were utilized that have demonstrated resilience to temperature and neutron flux up to 550 °C and 10 18 n/cm 2 , respectively. This paper will discuss the theory, design, calibration and uncertainty quantification of the flowmeter. The flowmeter was calibrated over a flowrate range of 11.4 - 90.9 LPM at temperatures of 220 and 400 °C, yielding an uncertainty in calibration of 2-3.6%. Here, a finite element model was developed and validated experimentally, yielding <; 3.2% error.

47 OTHER INSTRUMENTATION↗

Experimental studies on metallic fuel relocation in a pin bundle core structure of a sodium-cooled fast reactor

Understanding the relocation behavior of metallic fuel in severe accident scenarios is one of the most important factors in the safety assessment of sodium-cooled fast reactors (SFRs). In the present study, the relocation behavior of uranium metallic fuel was investigated by conducting metallic fuel relocation experiments using 19-pin bundle test sections in the Argonne's Metallic Uranium Safety Experiment (MUSE) facility. Post-test radiographic images were taken to characterize the uranium fuel relocation within the pin bundle test section. In addition, the pressure drop in the test sections was measured after the relocation experiments to evaluate the blockage of the sodium coolant channel. The pressure drop in the pin bundle test sections was also analytically calculated by varying the porosity and the pore size of the relocated fuel. The porosity and pore size of the relocated fuel in the pin bundle test sections were estimated by comparing those calculated pressure drop values with the measured pressure drop values from the pressure drop tests. In this work, the experimental results showed that the more formation of the eutectics could lead to more fuel dispersion and less blockage due to the lower freezing point of the eutectics.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on Level Sensor Development

This report details the development of sensors capable of measuring the level of liquid sodium at the Mechanisms Engineering Test Loop (METL) of Argonne National Laboratory. A differential pressure level sensor and variations of a mutually inductive level sensor have been designed, built, and tested in sodium at METL. A differential pressure level sensor was successfully calibrated during the initial dump tank sodium fill and continues to operate effectively. A differential pressure level sensor has been procured for use in the expansion tank. Three variations of mutually inductive level sensors have been designed, built, and tested in an out-of-sodium testing station in Building 308. The most advanced variation consists of a coil wound mineral insulated cable capable of continuous level measurement of liquid sodium up to 538°C over a range of 70”. Successful in-sodium testing occurred in late 2018.

47 OTHER INSTRUMENTATION↗

Fiscal Year 2018 Sodium-CO2 Interaction Test

An experiment campaign was continued in Fiscal Year 2018 in the Argonne National Laboratory (Argonne) SNAKE facility that investigated the interactions between supercritical carbon dioxide (sCO 2 ) and sodium through injection of sCO 2 into an open surface sodium pool. Two of fifteen previous SNAKE tests revealed that self-plugging of the leakage path/nozzle occurs at higher initial sodium temperatures of about 500 ºC due to chemical reactions involving CO 2 , sodium, and sodium-CO 2 reaction products. At lower sodium temperatures, the interaction phenomena involve consumption of injected CO 2 and formation of an agglomerated mass of reaction products without self-plugging. The FY 2018 test investigated interactions at an intermediate initial sodium temperature of about 411 ºC, representative of the interior of a sodium-to-CO 2 heat exchanger in a Sodium-Cooled Fast Reactor (SFR) sCO 2 Brayton Cycle energy conversion system. The experiment was successfully conducted and did not show self-plugging as evidenced by a sustained chemical reaction between the injected CO 2 and sodium and consumption of CO 2 .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY2017 Sodium-CO2 Interaction Tests

An experimental campaign was carried out in Fiscal Year 2017 in the ANL SNAKE facility that investigated the interaction between sCO 2 and sodium through injection of sCO 2 into a sodium-filled diffusion-bonded heat exchanger channel mock-up. This successful experiment demonstrated that a sustained chemical reaction between the injected CO 2 and sodium occurred at temperatures representative of the cold leg of an intermediate heat transport system for a SFR-to-sCO 2 Brayton Cycle energy conversion system. Evidence of the chemical reaction included: exothermic heatup of localized regions of the test vessel, production of carbon monoxide, consumption of CO 2 and production of solid reaction products that were observed during post-test examination. This experimental result was consistent with previous SNAKE experiments. Two of fourteen previous SNAKE tests confirmed that self-plugging of the leakage path/nozzle could occur at higher initial s odium temperatures due to chemical reactions involving CO 2 , sodium, and sodium-CO 2 reaction products. The remaining tests, including the one carried out in Fiscal Year 2017, began with low er initial temperatures and did not self-plug. A new model was developed to determine the reaction rate constant for sCO 2 injections into sodium by calculating the increase of bulk sodium temperature. This model will be developed further and used to simulate the behavior of reactor-scale sodium-to-sCO 2 heat exchanger failures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Advanced Demonstration and Test Reactor Options Study

Global efforts to address climate change will require large-scale decarbonization of energy production in the United States and elsewhere. Nuclear power already provides 20% of electricity production in the United States (U.S.) and is increasing in countries undergoing rapid growth around the world. Because reliable, grid-stabilizing, low emission electricity generation, energy security, and energy resource diversity will be increasingly valued, nuclear power’s share of electricity production has a potential to grow. In addition, there are non electricity applications (e.g., process heat, desalination, hydrogen production) that could be better served by advanced nuclear systems. Thus, the timely development, demonstration, and commercialization of advanced nuclear reactors could diversify the nuclear technologies available and offer attractive technology options to expand the impact of nuclear energy for electricity generation and non-electricity missions. The purpose of this planning study is to provide transparent and defensible technology options for a test and/or demonstration reactor(s) to be built to support public policy, innovation and long term commercialization within the context of the Department of Energy’s (DOE’s) broader commitment to pursuing an “all of the above” clean energy strategy and associated time lines. This planning study includes identification of the key features and timing needed for advanced test or demonstration reactors to support research, development, and technology demonstration leading to the commercialization of power plants built upon these advanced reactor platforms. This planning study is consistent with the Congressional language contained within the fiscal year 2015 appropriation that directed the DOE to conduct a planning study to evaluate “advanced reactor technology options, capabilities, and requirements within the context of national needs and public policy to support innovation in nuclear energy”. Advanced reactors are defined in this study as reactors that use coolants other than water. Advanced reactor technologies have the potential to expand the energy applications, enhance the competitiveness, and improve the sustainability of nuclear energy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Irradiation Testing Vehicles for Fast Reactors from Open Test Assemblies to Closed Loops

A review of irradiation testing vehicle approaches and designs that have been incorporated into past Sodium-Cooled Fast Reactors (SFRs) or envisioned for incorporation has been carried out. The objective is to understand the essential features of the approaches and designs so that they can inform test vehicle designs for a future U.S. Fast Test Reactor. Fast test reactor designs examined include EBR-II, FFTF, JOYO, BOR-60, PHÉNIX, JHR, and MBIR. Previous designers exhibited great ingenuity in overcoming design and operational challenges especially when the original reactor plant’s mission changed to an irradiation testing mission as in the EBRII reactor plant. The various irradiation testing vehicles can be categorized as: Uninstrumented open assemblies that fit into core locations; Instrumented open test assemblies that fit into special core locations; Self-contained closed loops; and External closed loops. A special emphasis is devoted to closed loops as they are regarded as a very desirable feature of a future U.S. Fast Test Reactor. Closed loops are an important technology for irradiation of fuels and materials in separate controlled environments. The impact of closed loops on the design of fast reactors is also discussed in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lessons Learned about Liquid Metal Reactors from FFTF Experience

The Fast Flux Test Facility (FFTF) is the most recent liquid-metal reactor (LMR) to operate in the United States, from 1982 to 1992. FFTF is located on the DOE Hanford Site near Richland, Washington. The 400-MWt sodium-cooled, low-pressure, high-temperature, fast-neutron flux, nuclear fission test reactor was designed specifically to irradiate Liquid Metal Fast Breeder Reactor (LMFBR) fuel and components in prototypical temperature and flux conditions. FFTF played a key role in LMFBR development and testing activities. The reactor provided extensive capability for in-core irradiation testing, including eight core positions that could be used with independent instrumentation for the test specimens. In addition to irradiation testing capabilities, FFTF provided long-term testing and evaluation of plant components and systems for LMFBRs. The FFTF was highly successful and demonstrated outstanding performance during its nearly 10 years of operation. The technology employed in designing and constructing this reactor, as well as information obtained from tests conducted during its operation, can significantly influence the development of new advanced reactor designs in the areas of plant system and component design, component fabrication, fuel design and performance, prototype testing, site construction, and reactor operations. The FFTF complex included the reactor, as well as equipment and structures for heat removal, containment, core component handling and examination, instrumentation and control, and for supplying utilities and other essential services. The FFTF Plant was designed using a “system” concept. All drawings, specifications and other engineering documentation were organized by these systems. Efforts have been made to preserve important lessons learned during the nearly 10 years of reactor operation. A brief summary of Lessons Learned in the following areas will be discussed: Acceptance and Startup Testing of FFTF FFTF Cycle Reports

Wootan, David W.↗

FY 2014 Sodium-Supercritical CO 2 Interactions in the SNAKE Experiment Facility

One appealing feature of the supercritical carbon dioxide Brayton cycle energy conversion system is the small footprint that the hardware requires, which is in part due to the use of compact diffusion-bonded heat exchangers such as Printed Circuit Heat Exchanger (PCHEs) or Hybrid Heat Exchangers (H 2 X) as the heat source heat exchanger (sodium-to-CO 2 ) as well as the recuperator and cooler modules. Although PCHEs and H 2 Xs have a high degree of structural integrity, the potential for leaks to develop between the sodium and CO 2 coolant channels in the heat exchanger cannot be ruled out, and this would lead to discharge of high pressure CO 2 into the secondary coolant circuit. Due to the robustness of the PCHE design, catastrophic failure leading to CO 2 jet blowdown into the secondary sodium loop is not deemed likely. Rather, small cracks (or micro-leaks) may develop in which CO 2 will bleed into the secondary system at a relatively low rate and chemically react with the sodium. The goal of the sodium-CO 2 interaction tests is to gain a fundamental understanding of sodium-CO 2 interactions under prototypical conditions of compact diffusion-bonded heat exchanger failure, a fundamental understanding of self-plugging if it occurs, and the development of one-dimensional phenomenological models for the interactions between high-pressure CO 2 issuing into liquid sodium from a micro-leak across a stainless steel pressure boundary. These models will be validated using experiment data. Therefore, an experiment program at Argonne was initiated in Fiscal Year 2010 to investigate the reaction behavior between sodium and CO 2 under micro-leak conditions. Several reports have described the facility scaling rationale and design. Assembly of the SNAKE (S-CO 2 , Na Kinetics Experiment) began in Fiscal Year 2011 and was completed in July 2012. The sodium inventory in this facility consists of approximately 44 lbs (20 kg; ~21 L/5.5 gal).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced Fast Reactor - 100 (AFR-100) Report for the Technical Review Panel

This report is written to provide an overview of the Advanced Fast Reactor-100 in the requested format for a DOE technical review panel. This report was prepared with information that is responsive to the DOE Request for Information, DE-SOL-0003674 Advanced Reactor Concepts, dated February 27, 2012 from DOE’s Office of Nuclear Energy, Office of Nuclear Reactor Technologies. The document consists of two main sections. The first section is a summary of the AFR-100 design including the innovations that are incorporated into the design. The second section contains a series of tables that respond to the various questions requested of the reactor design team from the subject DOE RFI.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Description of the First Observed Sodium-C0 2 Reactions in the Sodium CO 2 Interaction Experiment (SNAKE)

One appealing feature of the supercritical carbon dioxide Brayton cycle energy conversion system is the small footprint that the hardware requires, which is in part due to the use of Printed Circuit Heat Exchangers (PCHEs) as the heat source heat exchanger (sodium-to-CO 2 ) as well as the recuperator and cooler modules. Although PCHEs have a high degree of structural integrity, the potential for leaks to develop between the sodium and CO 2 coolant channels in the secondary heat exchanger cannot be ruled out, and this would lead to discharge of high pressure CO 2 into the secondary coolant circuit. Due to the robustness of the PCHE design, catastrophic failure leading to CO 2 jet blowdown into the secondary sodium loop is not deemed likely. Rather, small cracks (or micro-leaks) may develop in which CO 2 will bleed into the secondary system at a relatively low rate and chemically react with the sodium. The goal of the sodium-CO 2 interaction tests is to gain a fundamental understanding of sodium-CO 2 interactions under prototypical conditions of compact diffusion-bonded heat exchanger failure, a fundamental understanding of self-plugging if it occurs, and the development of one-dimensional phenomenological models for the interactions between high-pressure CO 2 issuing into liquid sodium from a micro-leak across a stainless steel pressure boundary. These models will be validated using experiment data. Therefore, an experiment program at Argonne was initiated in Fiscal Year 2010 to investigate the reaction characteristics between sodium and CO 2 under micro-leak conditions. Several reports have described the facility scaling rationale and design. Assembly of the SNAKE (S-CO 2 , Na Kinetics Experiment) began in Fiscal Year 2011 and was completed in July 2012. Approximately 44 lbs (20 kg; ~21 L/5.5 gal) of sodium was transferred into the SNAKE dump tank from a drum of clean sodium in July 2012.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗