Search NASA⌕ Search

Engineering topics

Granero, D

Publications and source records attributed to Granero, D.

SU-F-T-63: Dosimetric Relevance of the Valencia and Leipzig HDR Applicators Plastic Cap

Purpose: Utilization of HDR brachytherapy treatment of skin lesions using collimated applicators, such as the Valencia or Leipzig is increasing. These applicators are made of cup-shaped tungsten material in order to focalize the radiation into the lesion and to protect nearby tissues. These applicators have an attachable plastic cap that removes secondary electrons generated in the applicator and flattens the treatment surface. The purpose of this study is to examine the dosimetric impact of this cap, and the effect if the cap is not placed during the HDR fraction delivery. Methods: Monte Carlo simulations have been done using the code Geant4 for the Valencia and Leipzig applicators. Dose rate distributions have been obtained for the applicators with and without the plastic cap. An experimental study using EBT3 radiochromic film has been realized in order to verify the Monte Carlo results. Results: The Monte Carlo simulations show that absorbed dose in the first millimeter of skin can increase up to 180% for the Valencia applicator if the plastic cap is absent and up to 1500% for the Leipzig applicators. At deeper distances the increase of dose is smaller being about 10–15%. Conclusion: Important differences have been found if the plastic cap of the applicators is absent in the treatment producing an overdosage in the skin. The user should have a checklist to remind him check always before HDR fraction delivery to insure the plastic cap is placed on the applicator. This work was supported in part by Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156, and by a research agreement with Elekta Brachytherapy, Veenendaal, The Netherlands.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-248: FMEA Risk Analysis Implementation (AAPM TG-100) in Total Skin Electron Irradiation Technique

Purpose: Total Skin Electron Irradiation (TSEI) is a radiotherapy treatment which involves irradiating the entire body surface as homogeneously as possible. It is composed of an extensive multi-step technique in which quality management requires high consumption of resources and a fluid communication between the involved staff, necessary to improve the safety of treatment. The TG-100 proposes a new perspective of quality management in radiotherapy, presenting a systematic method of risk analysis throughout the global flow of the stages through the patient. The purpose of this work has been to apply TG-100 approach to the TSEI procedure in our institution. Methods: A multidisciplinary team specifically targeting TSEI procedure was formed, that met regularly and jointly developed the process map (PM), following TG-100 guidelines of the AAPM. This PM is a visual representation of the temporal flow of steps through the patient since start until the end of his stay in the radiotherapy service. Results: This is the first stage of the full risk analysis, which is being carried out in the center. The PM provides an overview of the process and facilitates the understanding of the team members who will participate in the subsequent analysis. Currently, the team is implementing the analysis of failure modes and effects (FMEA). The failure modes of each of the steps have been identified and assessors are assigning a value of severity (S), frequency of occurrence (O) and lack of detection (D) individually. To our knowledge, this is the first PM made for the TSEI. The developed PM can be useful for those centers that intend to implement the TSEI technique. Conclusion: The PM of TSEI technique has been established, as the first stage of full risk analysis, performed in a reference center in this treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-237: Monte Carlo Dosimetric Characterization of the Mobetron Mobile Linac

Purpose: The aim of this work is to characterize dosimetrically a clinical intraoperative electron beam accelerator, Mobetron (IntraOp Medical, Inc.) in clinical use in our Hospital. Once this first step is completed our purpose is to evaluate shielding requirements for such a device by preparing adequate phase space files. Methods: It is known that electron beam simulation parameters required for state-of-the-art Monte Carlo codes to obtain a good match with measured data, like the mean energy or the FWHM, may not be code-independent due to the different set of process simulated and formalisms involved. Then, to cross-check our results against any issue in the simulation we have compared experimental data (PDD and profiles for electrons in the range 4 to 12 MeV) with simulations performed independently using both Penelope2011 and Geant4 codes. To do so, the geometry and materials of the head of the accelerator have been fully characterized following information provided by the manufacturer. Results: Both simulations agree with experimental data within experimental uncertainties (±1 mm displacement), although small variations (less than 10%) in the mean energy and FWHM are required to match measured values depending on the code used. Conclusion: Independent Monte Carlo simulations were used to obtain an excellent match to measured electron dose distributions. This opens the road to use such data for evaluating shielding requirements which is the main objective of this project.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-343: Valencia Applicator Commissioning Using a Micro-Chamber Array

Purpose: In the commissioning and QA of surface isotope-based applicators, source-indexer distance (SID) has a great influence in the flatness, symmetry and output. To these purposes, methods described in the literature are the use of a special insert at the entrance of dwell chamber or radiochromic films. Here we present the experience with a micro-chamber array to perform the commissioning and QA of Valencia applicators. Methods: Valencia applicators have been used, the classic and the new extra-shielded version. A micro-chamber array has been employed, 1000 SRS (PTW), with 977 liquid filled, 2.3×2.3×0.5 mm{sup 3} sized ion chambers covering 11×11 cm{sup 2}, which spacing is 2.5 mm in the central 5.5×5.5 cm{sup 2}, dedicated mainly in principle, in conjunction with Octavius 4D (PTW), to IMRT, VMAT, SBRT verifications. Verisoft software that allows for 3D and planar analysis has been used to evaluate the results. Applicators were located on the surface of the array. To verify the SID, measurements corresponding to the reference value, SID ± 1 mm and SID ± 2 mm were acquired (integration time was fixed in order to discard the influence of the source entrance/exit). Once SID was determined, standard protocol treatments corresponding to 3 Gy and 7 Gy were acquired in order to establish typical patient dose distribution. Results: The method is fast and sensitive. The SID obtained was 1321 mm which is the nominal value included in the applicator manual. For example at 1319 mm an asymmetry of ±8% with respect to the central value was measured, along with a central deviation of −4% referred to 1321 mm. Conclusion: A practical method for the commissioning and QA of Valencia applicators has been described. It has been shown that it is an efficient and accurate tool for these purposes as well as for the verification of the absolute output constancy.

60 APPLIED LIFE SCIENCES↗