First Search for Lorentz and CPT Violation in Double Beta Decay with EXO-200
Abstract Not Provided
Engineering topics
Publications and source records attributed to Gratta, G..
Abstract Not Provided
EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless ββ decay of 136 Xe to the ground state of 136 Ba. We report here on a search for the two-neutrino ββ decay of 136 Xe to the first 0 + excited state, 0 + 1 , of Ba136 based on a 100 kg yr exposure of 136 Xe. Using a specialized analysis employing a machine learning algorithm, we obtain a 90% CL half-life sensitivity of 1.7×10 24 yr. We find no statistically significant evidence for the 2νββ decay to the excited state resulting in a lower limit of T 2ν 1/2 (0 + → 0 + 1 ) > 6.9 ×10 23 yr at 90% CL. In conclusion, this observed limit is consistent with the estimated half-life of 2.5×10 25 yr.
The search for neutrinoless double-beta decay ( 0 ν β β ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0 ν β β signal. We report on studies of various β and γ backgrounds in the liquid-xenon-based EXO- 200 0 ν β β experiment. With this work we try to better understand the location and strength of specific background sources and compare the conclusions to radioassay results taken before and during detector construction. Finally, we discuss the implications of these studies for EXO-200 as well as for the next-generation, tonne-scale nEXO detector.
Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence, and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba + deposits is identified with some type of barium hydride molecule. Lower limits for the fluorescence quantum efficiency of the principal Ba emission transition are reported. Under current conditions, an image of fewer than or equal to 10 4 Ba atoms can be obtained. Prospects for imaging single Ba atoms in solid xenon are discussed.
An RF ion-funnel technique has been developed to extract ions from a high-pressure (10 bar) noble-gas environment into a vacuum (10 -6 mbar). Detailed simulations have been performed and a prototype has been developed for the purpose of extracting 136 Ba ions from Xe gas with high efficiency. With this prototype, ions have been extracted for the first time from high-pressure xenon gas and argon gas. Systematic studies have been carried out and compared to simulations. This demonstration of extraction of ions, with mass comparable to that of the gas generating the high-pressure, has applications to Ba tagging from a Xe-gas time-projection chamber for double-beta decay, as well as to the general problem of recovering trace amounts of an ionized element in a heavy (m > 40 u) carrier gas.
Not Available
We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. Finally, an infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable’s motion, and the system was controlled via a graphical user interface.
We studied the removal of radioactivity from liquid scintillator in preparation of a low background phase of KamLAND. We describe the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. Lastly, we report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon daughters from liquid scintillator.
In this work, we report on an improved measurement of the 2 ν β β half-life of 136 Xe performed by EXO-200. The use of a large and homogeneous time-projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data-analysis methods used for double- β decay searches with EXO-200, while emphasizing those directly related to the present measurement. The 136 Xe 2 ν β β half-life is found to be T 1 / 2 2 ν β β = 2.165 ± 0.016 ( stat ) ± 0.059 ( sys ) × 10 21 yr. Finally, this is the most precisely measured half-life of any 2 ν β β decay to date.