Vector unsymmetric eigenequation solver for nonlinear flutter analysis on high-performance computers
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Gray, Carl E., Jr..
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The 8-foot High Temperature Tunnel (HTT) at LaRC is a combustion driven, high enthalpy blow down wind tunnel. In Mar. 1991, during check out of the transpiration cooled nozzle, pieces of platelets were found in the tunnel test section. It was determined that incorrect tolerancing between the platelets and the housing was the primary cause of the platelet failure. An analysis was performed to determine the tolerance layout between the platelets and the housing to meet the structural and performance criteria under a range of thermal, pressure, and bolt preload conditions. Three recommendations resulted as a product of this analysis.
Consideration is given to a finite-element approach for determining the nonlinear flutter characteristics of 3D thin laminated composite panels using the full third-order-piston transverse-loading aerodynamic theory. The unsteady hypersonic aerodynamic theory and the von Karman large-deflection-plate theory are used to formulate the aeroelasticity problem. Nonlinear flutter analyses are performed to assess the influence of the higher-order aerodynamic theory on the structure's limit-cycle amplitude and the dynamic pressure of the flow velocity. A solution procedure is presented to solve the nonlinear panel flutter and large-amplitude free-vibration finite-element equations. Nonlinear flutter analyses are performed for different boundary support-conditions and for various system parameters. Linear finite-element flutter for isotropic and composite panels and large-amplitude isotropic panel flutter results are compared with existing classical solutions. The large-amplitude panel flutter results using the full third-order piston aerodynamic theory are presented to assess the influence of the nonlinear aerodynamic theory.
A finite element approach is presented for determining the nonlinear flutter characteristics of composite panels using unsteady, third-order piston theory aerodynamics. Both nonlinear structural (large-amplitude) and nonlinear aerodynamics terms are considered in the finite element formulation. Solution procedures are presented to solve the nonlinear panel flutter and the large-amplitude free vibration finite element equations. Nonlinear aerodynamic and linear structural finite element flutter results for composite panels are also presented. An efficient, vector-version generalized unsymmetric eigenequation solver is developed for large-amplitude vibration and nonlinear panel flutter analyses on high-performance computers.
In January 1989 an accident occurred in the National Transonic Facility wind tunnel at NASA Langley Research Center that was believed to be caused by the failure of a thermal insulation retainer. A structural analysis of this retainer assembly was performed in order to understand the possible failure mechanisms. Two loading conditions are important and were considered in the analysis. The first is the centrifugal force due to the fact that this retainer is located on the fan drive shaft. The second loading is a differential temperature between the retainer assembly and the underlying shaft. Geometrically nonlinear analysis is required to predict the stiffness of this component and to account for varying contact regions between various components in the assembly. High, local stresses develop in the band part of the assembly near discontinuities under both the centrifugal and thermal loadings. The presence of an aluminum ring during a portion of the part's operating life was found to increase the stresses in other regions of the band. Under the centrifugal load, high bending stresses develop near the intersection of the band with joints in the assembly. These high bending stresses are believed to be the most likely cause for failure of the assembly.
Panel flutter is the self excited oscillations of a plate in supersonic flow. Linear theory gives no information about the panel's deflections and stresses. Hence, the service life of the panel cannot be predicted by linear methods. Nonlinear structural theory determines the limit cycle oscillating frequency, and also panel deflections and stresses. Panel fatigue life, therefore, can be predicted. For a more thorough understanding of panel flutter behavior, the geometric nonlinearity effects due to large deflections must be considered in the formulation. The Galerkin's method was used in the investigation of limit cycle oscillations of panels in supersonic flow in the spatial domain, and the panel deflections. All nonlinear flutter methods and results presently available were limited to a linear or linearized aerodynamic theory. Extension of the finite element flutter formulation to include nonlinear hypersonic aerodynamic loading and finite element nonlinear panel flutter results are presented.
Using the Newtonian method, the equations of motion are developed for the coupled bending-torsion steady-state response of beams rotating at constant angular velocity in a fixed plane. The resulting equations are valid to first order strain-displacement relationships for a long beam with all other nonlinear terms retained. In addition, the equations are valid for beams with the mass centroidal axis offset (eccentric) from the elastic axis, nonuniform mass and section properties, and variable twist. The solution of these coupled, nonlinear, nonhomogeneous, differential equations is obtained by modifying a Hunter linear second-order transfer-matrix solution procedure to solve the nonlinear differential equations and programming the solution for a desk-top personal computer. The modified transfer-matrix method was verified by comparing the solution for a rotating beam with a geometric, nonlinear, finite-element computer code solution; and for a simple rotating beam problem, the modified method demonstrated a significant advantage over the finite-element solution in accuracy, ease of solution, and actual computer processing time required to effect a solution.