Search NASA⌕ Search

Engineering topics

Gray, Tim J.

Publications and source records attributed to Gray, Tim J..

Shape polarization in the tin isotopes near N = 60 from precision g-factor measurements on short-lived 11/2 - isomers

The g factors of 11/2 - isomers in semimagic 109 Sn and 111 Sn (isomeric lifetimes $\tau$ = 2.9(3) ns and $\tau$ = 14.4(7) ns, respectively) were measured by an extension of the Time Differential Perturbed Angular Distribution technique, which uses LaBr3 detectors and the hyperfine fields of a gadolinium host to achieve precise measurements in a new regime of short-lived isomers. The results, g(11/2 - ; 109 Sn) = -0.186(8) and g(11/2 - ; 111 Sn) = -0.214(4), are significantly lower in magnitude than those of the 11/2 - isomers in the heavier isotopes and depart from the value expected for a near pure neutron h 11/2 configuration. Broken-symmetry density functional theory calculations applied to the sequence of 11/2 - states reproduce the magnitude and location of this deviation. The g(11/2 - ) values are affected by shape core polarization; the odd Oh 11/2 neutron couples to J π = 2 + , 4 + , 6 + ... configurations in the weakly-deformed effective core, causing a decrease in the g-factor magnitudes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Coincidence Counting for Improving Minimal Detectable Activity of 110m Ag in Single Particle Gamma Analysis

Post-irradiation examination (PIE) of fuel particles from the fourth Advanced Gas Reactor Fuel Development and Qualification (AGR) Program irradiation (AGR-5/6/7) is being performed at Oak Ridge National Laboratory (ORNL). Tristructural isotropic (TRISO)-coated particles and associated compacts for the AGR-5/6/7 experiment fabricated by BWX Technologies Nuclear Operations Group were formed into a graphite matrix compact and irradiated at the Advanced Test Reactor at Idaho National Laboratory. At ORNL, particles are deconsolidated from the graphite matrix compact and individually scanned for emitted gamma rays with the Irradiated Microsphere Gamma Analyzer (IMGA). The IMGA system comprises a single high purity germanium (HPGe) detector, an automated particle handling vacuum system, and an ORTEC DSPEC-50 digital spectrometer for gamma ray analysis. IMGA quantifies gamma ray-emitting fission product inventories of individual TRISO particles, and these inventories can be compared with the measured average inventories per particle and radionuclide inventories predicted by AGR-5/6/7 physics calculations to determine if a particle experienced radionuclide release. Details on IMGA data collection methods can be found in the literature. The TRISO particle’s SiC layer provides structural support, as well as a barrier for fission product release during irradiation or subsequent safety testing. A weakened or compromised SiC layer can be identified by the release of radionuclides, such as 137 Cs, which is detected by IMGA. However, select radionuclides, such as 90 Sr, 110 mAg, and 154 Eu have been shown to migrate through an intact SiC layer. Measurement of the radionuclide 110 mAg is significant as its release has been shown to be particularly sensitive to in-reactor conditions (e.g., temperature) with broad variable particle to-particle release behaviors observed within a single compact. As such, 110 mAg activity is often used for particle selection for comprehensive PIE as bounding 110 mAg retention particles are hypothesized to represent limits in particle behaviors within a compact. As TRISO particle fuel PIE activities continue over time, IMGA measurements of the 110 mAg inventory are eventually hindered because of its relatively short half-life (~250 days). As the fuel ages from its end of irradiation (EOI) date, the measurement uncertainty and minimum detectable activity (MDA) of 110m Ag increase because the detector background continuum begins to dominate. For particles from the second AGR irradiation experiment (AGR-2), the 110m Ag MDA was above 20% of the calculated average particle inventory after approximately five half-lives, and 110m Ag activity was no longer measurable with IMGA after approximately seven half-lives. Therefore, coincidence counting approaches have been explored to determine feasibility of leveraging new approaches to overcome limitations associated with increasing MDA over time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗